The network element could not find the source and/or destination ID for the specified cross-connections in the circuit.
|
Alarm Data |
Value/Meaning |
|---|---|
|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Minor (MN) |
|
ASAP Type |
BLSR Protection Group |
|
AID Type |
STS-n Ring Channel VT Ring Channel |
|
Date |
Month/day/year that the condition was detected |
|
Time |
Hour:minute:second that the condition was detected |
|
Probable Cause |
SQDATA-UNAV (Squelch Map Unavailable) |
|
Effect on Service |
NSA |
|
Alarm Entity Type |
COM |
|
Description |
Squelch Data Unavailable |
|
Likely Cause |
User selected Configuration → Equipment, selected the Ptn Grp, selected a 2F BLSR protection group and provisioned the Auto Squelch Map to Auto. All cross-connects in the circuit are not provisioned. Therefore, the network element cannot complete the squelch map. |
|
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) |
|
Action |
Proceed to Procedure 5-132: Clear "Squelch Data Unavailable" alarm. |