The main shelf or a subshelf in a multishelf DCS system has failed to receive at least one valid inter-shelf communication message in any 60 +/-5 second interval.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Major (MJ) |
ASAP Type |
Subshelf |
AID Type |
Subshelf |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
REMLINK (Host/Remote Subsystem Link Failure) |
Effect on Service |
CR, MJ, MN = NSA Not Alarmed = Standing Condition (SC) |
Alarm Entity Type |
EQPT |
Description |
Subshelf Communication Failed |
Likely Cause |
The LAN3 connection, identified as DLAN on the back of a shelf, or the control communications link between the main shelf and each subshelf failed. To support more than one subshelf, the LAN3 port of the main shelf and of each subshelf must be connected to an Ethernet hub capable of supporting 100Mb operation. No special cable is required. |
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, Minor, or Not Alarmed respectively). |
Action |
Proceed to Procedure 5-134: Clear "Subshelf Communication Failed” alarm. |