Subshelf Configuration Mismatch

Description

During the subshelf startup procedure, a subshelf detected the local subshelf information (subshelf MAC address and ssconfig.dat file) does not match the subshelf information provisioned on the main shelf. The Subshelf Configuration Mismatch alarm is only reported in the maintenance mode.

Alarm Data

Value/Meaning

Severity Levels

Minor (MN)

AID Type

Subshelf

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

DATAFLT (Data Integrity Fault)

Effect on Service

NSA

Alarm Entity Type

COM

Description

Subshelf Configuration Mismatch

Likely Cause

The local subshelf information (subshelf MAC address and ssconfig.dat file) does not match the subshelf information provisioned on the main shelf.

Visible Indication

Lighted MN LED on the SYSCTL faceplate.

Action

Proceed to Procedure 5-135: Clear "Subshelf-related" alarms/conditions.