During the subshelf startup procedure, a subshelf detected the local subshelf information (subshelf MAC address and ssconfig.dat file) does not match the subshelf information provisioned on the main shelf. The Subshelf Configuration Mismatch alarm is only reported in the maintenance mode.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Minor (MN) |
AID Type |
Subshelf |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
DATAFLT (Data Integrity Fault) |
Effect on Service |
NSA |
Alarm Entity Type |
COM |
Description |
Subshelf Configuration Mismatch |
Likely Cause |
The local subshelf information (subshelf MAC address and ssconfig.dat file) does not match the subshelf information provisioned on the main shelf. |
Visible Indication |
Lighted MN LED on the SYSCTL faceplate. |
Action |
Proceed to Procedure 5-135: Clear "Subshelf-related" alarms/conditions. |