Use this procedure to change the following:
To provision the default port maintenance and default tributary maintenance parameters for new ports/tributaries that are created, refer to Procedure 6-2: Provision shelf/system parameters.
Access to the loopback and test transmission commands for ports is controlled using the Port Maintenance parameter. If the Port Maintenance parameter is provisioned to Allow, loopbacks and transmission testing are allowed on the port. Existing loopbacks and current transmission tests are not changed.
If the Port Maintenance parameter is provisioned to Inhibit, new loopbacks and transmission testing are not allowed on the port. If the port already has a loopback provisioned or is being transmission tested, attempting to change the Port Maintenance parameter to Inhibit is denied.
Access to the test access commands for tributaries is controlled using the Tributary Maintenance parameter. If the Tributary Maintenance parameter is provisioned to Allow, test access is allowed on the tributary. Test access that is already provisioned is not changed.
If the Tributary Maintenance parameter is provisioned to Inhibit, new test access provisioning is not allowed using the tributary. If the tributary already has test access provisioned, attempting to change the Tributary Maintenance parameter to Inhibit is denied.
You must log in as a Privileged user to complete this procedure.
Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Perform the following steps to change the port/tributary maintenance state of an existing port/tributary.
1 |
Result: The Allow/Inhibit Port/Tributary Maintenance window opens. | ||||||
2 |
Find the circuit pack with the port/tributary being provisioned, then expand the equipment list by clicking on the plus (+) sign next to the circuit pack and port (if required). Select the required port/tributary and click Select. | ||||||
3 |
Select Allow or Inhibit according to the work instructions and click Apply. For more information about Port Maintenance and Tributary Maintenance, refer to Port maintenance and Tributary maintenance. | ||||||
4 |
If required, repeat Step 2 and Step 3 to change the port/tributary maintenance state on other existing ports/tributaries; otherwise, click Close to exit. End of steps |
November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |