Procedure 4-23.1: Change slot protection state to unprotected for low-speed OLIU

Steps

Complete the following steps to change the Slot Protection State from Protected to Unprotected for a Function/Growth group equipped with low-speed OLIU circuit packs:

 
1

Important!

If cross-connections exist to a protected port on the affected circuit pack, the port Signal Type and Application parameters cannot be changed.

From the System View, select View → Cross-Connections to obtain a current list of cross-connections and verify that no cross-connections exist to protected ports on the affected circuit pack.

If required, select Configuration → Cross-Connections to access the Cross-Connection Wizard and delete any existing cross-connections to protected ports on the affected circuit pack.


2

From the System View, select Configuration → Update System → Update All.


3

From the System View, select Configuration → Equipment.

Result:

The Configure Equipment window opens.


4

Find the required low-speed OLIU circuit pack, then expand the equipment list by clicking on the plus (+) sign next to the low-speed OLIU circuit pack


5

Select a port and click Select.

Result:

The port parameters appear.


6

Provision the port Signal Type parameter STNA (LNW55 circuit pack only) or Application parameter 0x1 and click Apply.

Result:

If the port Signal Type parameter is changed to STNA and a pluggable transmission module is installed, the system reports an unexpected or failed Pluggable Transmission Module alarm.


7

If required, remove the affected pluggable transmission module and select Configuration → Update System → Update All to clear the unexpected or failed Pluggable Transmission Module alarm.


8

Important!

Either each port Signal Type parameter must be provisioned STNA (LNW55 circuit pack only) or the port Application parameter must be provisioned 0x1 on the affected low-speed OLIU circuit pack.

If required, repeat Step 3 through Step 7 to provision the remaining ports; otherwise, click Close.

Result:

When either the port Signal Type parameter is STNA (LNW55 circuit pack only) or the port Application parameter is 0x1 for all ports on the low-speed OLIU circuit pack, the Slot Protection State changes to Unprotected. The Slot Protection State change affects both slots in the Function/Growth group.


9

Select View → Equipment to access the affected circuit packs and verify that the Slot Protection State changed to Unprotected.


End of steps