Complete the following steps to change the Slot Protection State from Protected to Unprotected for a Function/Growth group equipped with low-speed OLIU circuit packs:
1 |
Important! If cross-connections exist to a protected port on the affected circuit pack, the port Signal Type and Application parameters cannot be changed. From the System View, select View → Cross-Connections to obtain a current list of cross-connections and verify that no cross-connections exist to protected ports on the affected circuit pack. If required, select Configuration → Cross-Connections to access the Cross-Connection Wizard and delete any existing cross-connections to protected ports on the affected circuit pack. |
2 |
From the System View, select Configuration → Update System → Update All. |
3 |
From the System View, select Configuration → Equipment. Result: The Configure Equipment window opens. |
4 |
Find the required low-speed OLIU circuit pack, then expand the equipment list by clicking on the plus (+) sign next to the low-speed OLIU circuit pack |
5 |
Select a port and click Select. Result: The port parameters appear. |
6 |
Provision the port Signal Type parameter STNA (LNW55 circuit pack only) or Application parameter 0x1 and click Apply. Result: If the port Signal Type parameter is changed to STNA and a pluggable transmission module is installed, the system reports an unexpected or failed Pluggable Transmission Module alarm. |
7 |
If required, remove the affected pluggable transmission module and select Configuration → Update System → Update All to clear the unexpected or failed Pluggable Transmission Module alarm. |
8 |
Important! Either each port Signal Type parameter must be provisioned STNA (LNW55 circuit pack only) or the port Application parameter must be provisioned 0x1 on the affected low-speed OLIU circuit pack. If required, repeat Step 3 through Step 7 to provision the remaining ports; otherwise, click Close. Result: When either the port Signal Type parameter is STNA (LNW55 circuit pack only) or the port Application parameter is 0x1 for all ports on the low-speed OLIU circuit pack, the Slot Protection State changes to Unprotected. The Slot Protection State change affects both slots in the Function/Growth group. |
9 |
Select View → Equipment to access the affected circuit packs and verify that the Slot Protection State changed to Unprotected. End of steps |