Procedure 14-13: Perform LED test

- Overview

Use this procedure to test circuit pack LEDs.

Important!

The LED test does not affect the LEDs on the fan unit

- Privilege level

You must log in as either a Privileged, General, or Maintenance user to complete this procedure.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Electrostatic discharge in Chapter 1, Safety.

  3. Ensure that Alcatel-Lucent 1665 DMXtend is equipped with required circuit packs at the node being tested.

Steps

Complete the following steps to perform the LED test.

 
1

Important!

All LEDs on the shelf may be tested using Fault → Test → LED or the ACO TEST push-button on the SYSCTL circuit pack. The Fault → Test → LED command may also be used to test LEDs on an individual circuit pack. The LED test does not affect the LEDs on the fan unit

If using the...

Then...

ACO TEST push-button on the SYSCTL circuit pack,

Continue with Step 2.

Fault → Test → LED command,

Proceed to Step 4.


2

Press and hold the ACO TEST push-button momentarily on the SYSCTL circuit pack. Verify that all circuit pack LEDs light, and release the ACO TEST push-button. The LEDs revert to their previous state.

If the ACO TEST push-button is pressed for two or more seconds and released, the IND display on the SYSCTL circuit pack faceplate shows the generic software version.


3

Did the LED test pass?

If...

Then...

Yes

STOP! End of Procedure.

No

Contact your next level of support.


4

From the System View menu, select Fault → Test → LED.


5

Highlight Shelf (tests all shelf LEDs) or CP xxx (tests individual circuit pack LEDs) and click Select.

Result:

The Test LED window opens.


6

In the Number of Iterations field, enter a number from 1 to 10 from the pull-down menu to indicate the number of cycles during which the LED test should be repeated and click OK.

Important!

On-site personnel must be physically in front of NE to witness the LED test cycles.

Result:

For each iteration:

  1. All LEDs for the specified address light.

  2. After 10 seconds, all LEDs go off.

  3. After another 10 seconds, all LEDs are updated to show the current status of the system.


7

Did the LED test pass?

If...

Then...

Yes,

STOP! End of Procedure.

No,

Contact your next level of support.


End of steps