Procedure 14-7: Perform end-to-end optical line test on Main OLIUs

- Overview

Use this procedure to verify the integrity of a high-speed OC-n line.

Important!

This test must be performed locally at each Alcatel-Lucent 1665 DMXtend shelf location associated with the optical span(s) being tested.

- Privilege level

You must log in as either a Privileged, General, or Maintenance user to complete this procedure.

Important!

It is assumed that each Alcatel-Lucent 1665 DMXtend node has passed the local (looped) transmission tests. If these tests have not been completed, refer to the appropriate procedure and perform the tests.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.

  3. Obtain the work instructions for this procedure.

Steps

Complete the following steps to verify the integrity of a high-speed OC-n line.

 
1

From the System View menu, select Performance → View PM/Statistics Report → OCn Line.

Result:

The OCn Line PM Report window opens.


2

Expand the CP main-1 (OCn) circuit pack by clicking on the plus sign (+), select Port 1 (OCn), and then click Select.

Result:

The port performance monitoring parameters appear.


3

Provision the Time Period parameter 15 Min, the Monitored Date parameter Current Date, the Monitor Time parameter Current, and the Monitor Level parameter 1-UP. Then move all the Near End Available Parameters to Selected Parameters by clicking Select All. Click Apply to obtain the OCn Line PM Report.

Result:

The OCn Line PM Report appears. The report should be empty, indicating no errors.


4

Wait 20 seconds and click Refresh on the OCn Line PM Report window. If a 15-minute boundary is crossed during the 20-second wait period, repeat this step.

Result:

If the report is still empty, the optical span is error-free. Click Close.


5

Did report indicate any errors?

If...

Then...

Yes,

Continue with Step 6.

No,

Proceed to Step 7.


6

Trouble may be in optical and/or fiber connections. Trouble may also be in OLIUs. If report indicated trouble when the report was obtained from the near end of the span, trouble may be in the receive direction. If the report indicated trouble when the report was obtained from the far end of the span, trouble may be in the transmit direction. Check optical fiber and connections. Clean optical fiber connections.

Reference:

Procedure 14-3: Clean optical fibers, dual LC adapters and LC lightguide buildouts (LBOs)

If no trouble was found in the optical fiber, click the Alarm List button to obtain the NE Alarm List. Refer to the Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Alarm Messages and Trouble Clearing Guide, 365-372-326 to clear/isolate the trouble.


7

If required, repeat this procedure from Step 2 for the Main-2 OLIU; otherwise, click Close.


8

Have you retrieved error-free performance-monitoring reports from all shelf locations associated with the optical span(s) being tested?

If...

Then...

Yes,

STOP! End of Procedure.

No,

Repeat this procedure from Step 1 at the other shelf locations.


End of steps

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.