Procedure 6-10: Assign alarm severity assignment profile

- Overview

Use this procedure to assign a DEFAULT or user-created alarm severity assignment profile (ASAP) to an entity within the system (for example, system, circuit pack, or port).

ASAPs cannot be preassigned to an entity before the entity is created in the system.

When an entity is created in the system (for example, a slot is equipped with a circuit pack), the system assigns the associated DEFAULT ASAP to the entity.

Different ASAPs within an ASAP type may be assigned to different entities within the system; however, only one ASAP may be assigned to an entity at a time. Assigning a different ASAP to an entity will override the previous assignment. The specified ASAP must agree with the allowed ASAP type for that entity in order to be assigned to the entity.

To create a new ASAP, refer to Procedure 6-7: Provision new alarm severity assignment profile.

To change an existing ASAP, refer to Procedure 6-8: Change existing alarm severity assignment profile.

ASAP types

The system supports the following ASAP types:

  • 1+1 Bidirectional Protection Group

  • Data Port

  • DS1 Port

  • DS3 Port

  • E1 Port

  • EC1 Port

  • Circuit Pack

  • Fast Ethernet Port

  • Gigabit Ethernet Port

  • Link Aggregation Group

  • Non-Volatile Memory Module

  • OCH Port

  • OCn Port

  • ODU2 Tributary

  • OTS Port

  • OTU2 Port

  • Pluggable Transmission Module

  • STS Ring Channel

  • System

  • System Timing

  • VC12 Ring Channel

  • VCG Port

  • VCG STS Tributary

  • VCG VT1.5 Tributary

  • VT1.5 Ring Channel

- Privilege level

You must login as either a Privileged or General user to complete this procedure.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Obtain the work instructions for this procedure.

  3. Verify that the work instructions identify the entity (for example, system, circuit pack or port) and the ASAP to be assigned.

Steps

Perform the following steps to assign a DEFAULT or user-created alarm severity assignment profile (ASAP) to an entity within the system (for example, system, circuit pack, or port).

 
1

From the System View menu, select Configuration → Equipment.

Result:

The Configure Equipment window opens.


2

Select the required entity according to the work instructions and click Select.

Result:

The provisionable parameters appear.


3

If required, click View Details to view the DEFAULT ASAP and the user-created ASAPs (if provisioned) for the associated ASAP type. Click Close.


4

Select the required ASAP according to the work instructions and click Apply.

Result:

A warning may appear asking you to confirm executing this command. Click Yes. Click Close to exit.


5

From the System View menu, select View → Equipment.

Result:

The View Equipment window opens.


6

Select the required entity according to the work instructions and click Select.

Result:

The entity details appear.


7

Using the work instructions, verify that the correct ASAP was assigned to the entity. Click Close to exit.


End of steps