Use this procedure to upgrade a software generic from Release 3.1.3/5.1.7 to Release 9.1.x via FTAM.
Refer to Required equipment in Procedure 2-4: Upgrade software generic via FTAM for a list of equipment required to perform this procedure.
Complete the following steps to upgrade a software generic from Release3.1.3/5.1.7 or later to Release 9.1.x.
1 |
From the System View menu, select Configuration → Software → Remote Backup. | ||||||||||||||||||||||||||||||||||
2 |
In the pull-down Backup To/Via: menu, select FTAM. | ||||||||||||||||||||||||||||||||||
3 |
In the Source/Destination Directory Path field, enter \backups\<filename>. You can also click the Browse button next to the Path: field to browse to any directory on your PC. Important! The value of the Path field can be either an absolute path or a relative path that is relative to the FTP server root directory. The absolute path must start with the drive name followed by a colon (:) then the path names; for example: C:\temp\today\backup. The syntax of the relative path must start with the path name; for example: \temp\backup. The WaveStar® CIT directory automatically enters the relative path for the WaveStar® CIT. The default relative path is C:\Program Files\Alcatel-Lucent\WaveStar CIT\ If you had an older WaveStar® CIT installed prior to installing the current WaveStar® CIT, your path could start with C:\Program Files\Lucent Technologies\. If you wish to store your data in a subdirectory, enter \backups\<subdirectory>\<filename> if the subdirectory exists before the command is sent. If any directory in the path does not exist, the command is denied because this command does not create directories. | ||||||||||||||||||||||||||||||||||
4 |
Click OK. You are asked to verify that you wish to backup to the directory that you entered. Click Yes if you typed the path correctly. Result: The Progress Indicator screen appears, indicating that the backup is in progress. When the backup completes, a Remote Backup successful screen appears. Click OK. The backup file is now stored. If the default path and a subdirectory were used, the file can be found at: C:\Program Files\Alcatel-Lucent\\WaveStar CIT\backups\<subdirectory>\<filename> If you had an older WaveStar® CIT installed prior to installing the current WaveStar® CIT, your path could start with C:\Program Files\Lucent Technologies\. | ||||||||||||||||||||||||||||||||||
5 |
Close your WaveStar® CIT session with the 3.1.x NE. From the System View, select File → NE Disconnect and click Yes in the confirmation window. Result: The System View closes. | ||||||||||||||||||||||||||||||||||
6 |
Disconnect the LAN and/or serial cables from the LAN and/or RS232 port(s) on the front of the LNW1 SYSCTL. | ||||||||||||||||||||||||||||||||||
7 |
Initiate a ten-second countdown (9, 8, 7, 6, 5, 4, 3, 2, 1, 0) in the IND display on the LNW1 SYSCTL by simultaneously depressing the ACO TEST and SEL buttons on the front of the LNW1 SYSCTL. Important! Removing the LNW1 without initiating the ten-second countdown can result in unexpected and undesirable protection switches, incorrect circuit fault indications, or incoming signal failure alarms. All SYSCTL functions are suspended during the countdown. | ||||||||||||||||||||||||||||||||||
8 |
Remove the LNW1 SYSCTL circuit pack during the 10-second countdown. Important! While the SYSCTL circuit pack is removed, do NOT remove or replace any transmission circuit packs. | ||||||||||||||||||||||||||||||||||
9 |
Important! For software installation, ensure that two NVMs are present in the LNW2 SYSCTL. After the LNW2 is installed, if one or two NVMs are missing, NVM removed alarm(s) are issued. If both NVM sockets are empty, the IND displays an alternating E and 0 and 1. Refer to Step 10 for the complete listing of codes and required actions. Seat the new LNW2 SYSCTL circuit pack and allow a few minutes for the pack to complete initialization. Result: The LNW2 SYSCTL exhibits the following visible cycles during initialization:
| ||||||||||||||||||||||||||||||||||
10 |
Observe the IND display on the LNW2 SYSCTL; the display indicates the state of the SYSCTL.
| ||||||||||||||||||||||||||||||||||
11 |
Connect the cross-over LAN cable from the Network Interface Card (NIC) on the PC to the front LAN port on the SYSCTL circuit pack faceplate and establish a WaveStar® CIT session. (When TCP/IP is enabled on the rear LAN port J17 IAO LAN, OSI is disabled.) | ||||||||||||||||||||||||||||||||||
12 |
From the Network View of the WaveStar® CIT session you established in Procedure 2-4: Upgrade software generic via FTAM, select the View: pull-down menu and select CIT OSI Neighbors. Important! This View: is not the menu bar item View → ...; it is located above the NE Name pull-down menu. | ||||||||||||||||||||||||||||||||||
13 |
From the Network View, select View → Refresh OSI View. Result: The CIT OSI neighbor(s) are automatically detected. Your TID is LT-DMXtend; when in Maintenance Mode, the TID is always default. | ||||||||||||||||||||||||||||||||||
14 |
In the Network View, right-click the LT-DMXtend NE icon that was detected, and select Graphical Using → OSI from the resulting menu. Result: The System Type Selection window appears. | ||||||||||||||||||||||||||||||||||
15 |
In the System Type Selection window, select DMXtend and click OK. Result: The NE Login Dialog window appears. | ||||||||||||||||||||||||||||||||||
16 |
Important! Because the shelf is in Maintenance Mode, your logins and passwords are default. Enter the following in the NE Login Dialog window (login information is case sensitive) to log in to the NE: User ID: LUC01 Password: DMXTND2.5G Click OK. Important! After you select your backup database, complete the Maintenance Mode Wizard, and the NE restarts, your original User IDs and Passwords are restored. Result: Screen 1 of 6 in the Maintenance Mode Wizard appears. Depending on the boot code of your SYSCTL (refer to Step 10), the title bar of the Maintenance Mode Wizard displays either DMXtend 4.0, DMXtend 5.0, DMXtend 5.1, DMXtend 8.0, DMXtend 9.0, or DMXtend 9.1. This screen picks up the time format preference from the WaveStar® CIT. You can provision the time format display for your WaveStar® CIT from the Network View by selecting View → Preferences and clicking the Display tab. This screen allows you to choose your preference for time format, either a 12-hour clock or a 24-hour clock.
| ||||||||||||||||||||||||||||||||||
17 |
Important! The actual time and date are preset from your PC. On Screen 1 of 6 in the Maintenance Mode Wizard, read the information, verify the date and time, make any required changes, and click Next. Result: Screen 2 of 6 in the Maintenance Mode Wizard appears. | ||||||||||||||||||||||||||||||||||
18 |
On Screen 2 of 6 in the Maintenance Mode Wizard, click Download. Result: Screen 1 of 3 in the Download Generic Wizard appears. | ||||||||||||||||||||||||||||||||||
19 |
On Screen 1 of 3 in the Download Generic Wizard, read the information, select FTAM and click Next. Result: Screen 2 of 3 in the Download Generic Wizard appears. | ||||||||||||||||||||||||||||||||||
20 |
Important! LAN-1 is the LAN port on the faceplate of the LNW2 SYSCTL circuit pack. LAN-2 is the J17 IAO LAN port on the rear of the Alcatel-Lucent 1665 DMXtend shelf. On Screen 2 of 3 in the Download Generic Wizard, read the information, verify that the LAN port you are connected to has OSI Function Enable selected, and click Next. Result: Screen 3 of 3 in the Download Generic Wizard appears. | ||||||||||||||||||||||||||||||||||
21 |
On Screen 3 of 3 in the Download Generic Wizard in the Path panel, enter the current location of the generic to be downloaded in the Path field or use the Browse button to select the generic to be downloaded. Click Download. The value of the Path field can be either an absolute path or a relative path that is relative to the FTP server root directory. The absolute path must start with the drive name followed by a colon (:) then the path names; for example: C:\Program Files\Alcatel-Lucent\WaveStar CIT\generics\DXT\9.1.0\p. The syntax of the relative path must start with the path name; for example: \generics\DXT\9.1.0\p. If you had an older WaveStar® CIT installed prior to installing the current WaveStar® CIT, your path could start with C:\Program Files\Lucent Technologies\. If necessary, replace 9.1.0 with your current release, for example 9.1.1. Result: A warning message appears listing the options you provisioned in the previous screens. | ||||||||||||||||||||||||||||||||||
22 |
Verify the information and either click Yes to start the download process or click No to return to the download screen and change your selections. Result: If you choose yes, the following initial software download progress indicator runs for approximately 30 minutes. | ||||||||||||||||||||||||||||||||||
23 |
Once the software generic download is complete, the following confirmation message appears. Click Yes to use the generic that is now in the Dormant area. Result: Screen 3 of 6 in the Maintenance Mode Wizard appears. | ||||||||||||||||||||||||||||||||||
24 |
Important! Do NOT select the default database or you could loose service to your shelf. You MUST download your previously backed up database. On Screen 3 of 6 in the Maintenance Mode Wizard, click Download. Result: Screen 1 of 3 in the Download Database Wizard appears. | ||||||||||||||||||||||||||||||||||
25 |
On Screen 1 of 3 in the Download Database Wizard, read the information, select FTAM and click Next. Result: Screen 2 of 3 in the Download Database Wizard appears. | ||||||||||||||||||||||||||||||||||
26 |
On Screen 2 of 3 in the Download Database Wizard, read the information, verify that the LAN port you are connected to has OSI Function Enable selected, and click Next. Result: Screen 3 of 3 in the Download Database Wizard appears. | ||||||||||||||||||||||||||||||||||
27 |
On Screen 3 of 3 in the Download Database Wizard in the Path panel, enter the location where the database information is stored. Enter the path and filename exactly as it was entered in Step 3. For example: \backups\<subdirectory>\<filename>. You can also click the Browse button next to the Path: field to browse to any directory on your PC and select the required file. Click Download. Important! The value of the Path field can be either an absolute path or a relative path that is relative to the FTP server root directory. The absolute path must start with the drive name followed by a colon (:) then the path names; for example: C:\temp\today\backup. The syntax of the relative path must start with the path name; for example: \temp\backup. The WaveStar® CIT directory automatically enters the relative path for the WaveStar® CIT. The default relative path is C:\Program Files\Alcatel-Lucent\WaveStar CIT\ If you had an older WaveStar® CIT installed prior to installing the current WaveStar® CIT, your path could start with C:\Program Files\Lucent Technologies\. Result: A warning message appears listing the options you provisioned in the previous screens. | ||||||||||||||||||||||||||||||||||
28 |
Verify the information and click Yes. Result: If you choose Yes, the database download progress indicator runs for approximately two minutes. | ||||||||||||||||||||||||||||||||||
29 |
Once the database download is complete, the following confirmation message appears. Click Yes to use the database that is now in the Backup area. Result: Screen 6 of 6 in the Maintenance Mode Wizard appears. In this screen, 9.1.0 is an example; your selected generic could be different, for example 9.1.1. 3.1.3 is an example too; your selected database could be 3.1.7 | ||||||||||||||||||||||||||||||||||
30 |
On Screen 6 of 6 in the Maintenance Mode Wizard, read the information, verify that you have selected the correct generic and database, and click Finish to restart the system and apply the generic and database. Result: The Maintenance Mode Wizard closes and your connection to the shelf is terminated. The LNW2 SYSCTL exhibits the following visible cycles while the generic and database are installed and validated and the SYSCTL reboots:
| ||||||||||||||||||||||||||||||||||
31 |
To verify that the upgrade was successful, depress and hold the ACO TEST push-button on the LNW2 SYSCTL for about 4 seconds. Result: All LEDs on the shelf light. A red, 35-segment (5 x 7) rectangle appears in the IND display on the SYSCTL. Since the IND display is a 35-segment display, this test indicates all segments are working. | ||||||||||||||||||||||||||||||||||
32 |
Release the ACO TEST push-button on the LNW2 SYSCTL when the red rectangle disappears in the IND display. Result: The current software generic appears in the IND display on the LNW2 SYSCTL and the shelf LEDs return to their previous status. | ||||||||||||||||||||||||||||||||||
33 |
From the Network View of the WaveStar® CIT session you established in Procedure 2-4: Upgrade software generic via FTAM, select the View: pull-down menu and select CIT OSI Neighbors. Important! This View: is not the menu bar item View → ...; it is located above the NE Name pull-down menu. | ||||||||||||||||||||||||||||||||||
34 |
From the Network View, select View → Refresh OSI View. Result: The CIT OSI neighbor(s) are automatically detected. Your TID is your original TID, the same TID provisioned on your 3.1.xNE. | ||||||||||||||||||||||||||||||||||
35 |
In the Network View, right-click the NE icon that was detected, and select Graphical Using → OSI from the resulting menu. Result: The System Type Selection window appears. | ||||||||||||||||||||||||||||||||||
36 |
In the System Type Selection window, select DMXtend and click OK. Result: The NE Login Dialog window appears. | ||||||||||||||||||||||||||||||||||
37 |
In the NE login window, login to the shelf using your original user ID and password. Click OK. Result: The title bar of the System View and the legal notice text both reflect the current NE software generic, for example: 9.1.0. Reference: Procedure 14-2: Connect Personal Computer (PC) and establish WaveStar® CIT session | ||||||||||||||||||||||||||||||||||
38 |
Is the Generic Software Version correct?
End of steps |
November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |