Procedure 12-16.1: Verify status of node

Important!

This is not a stand-alone procedure. Perform this procedure only as directed by another procedure.

Steps

Complete the following steps to verify the status of a node that terminates the OC-192 span being upgraded.

 
1

Click the Alarm List button in the top right corner of the System View to view the NE Alarm List and verify that no alarms are present.

Refer to the appropriate trouble clearing procedures to clear all existing alarms before continuing with this procedure.

Reference:

Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Alarm Messages and Trouble Clearing Guide, 365-372-326


2

To verify that no loopbacks, protection switch lockouts, or protection switches are present, select View → Rolling Events. Under the line reading RTRV-COND-ALL determine if any loopbacks, protection switch lockouts, or protection switches are displayed.

Remove all existing loopbacks, protection switch lockouts, or protection switches before continuing with this procedure.

Reference:

Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) Alarm Messages and Trouble Clearing Guide, 365-372-326


3

Select Fault → Analysis → Test Access to access the Test Access Wizard and verify that no test access sessions exist.

If required, select Fault → Analysis → Test Access to access the Test Access Wizard and delete all existing test access sessions.

Reference:


End of steps