Procedure 5-64: Clear "inc. section trace identifier mismatch" alarms

- Overview

This procedure is used to clear the following alarms:

  • inc. EC1 section trace identifier mismatch

  • inc. EC1 section trace identifier mismatch, diagnostic

  • inc. OCN section trace identifier mismatch

  • inc. OCN section trace identifier mismatch, diagnostic

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Electrostatic discharge in Chapter 1, Safety.

  3. Obtain office records showing the correct values for the local Expected Receive Section Trace Format and Expected Receive Section Trace Value parameters.

Steps

Complete the following steps to clear an inc. section trace identifier mismatch alarm.

 
1

From the WaveStar® CIT System View, click the Alarm List button and locate the inc. section trace identifier mismatch alarm in the resulting Alarm List and note the corresponding AID.


2

Important!

A mismatch exists between the actual Incoming Receive Section Trace Format/Value and the provisioned Expected Receive Section Trace Format/Value.

Select View → Equipment to access to the required circuit pack with the affected port. Expand the equipment list by clicking on the plus (+) sign next to the required circuit pack. Click (highlight) the affected port, then click Select at the bottom of the window.

Result:

The port parameters appear.


3

Click the J0 Section Trace tab.

Result:

The port J0 section trace parameters appear.


4

Record the provisioned Expected Receive Section Trace Format and Expected Receive Section Trace Value parameters. Click Close.


5

Using office records and local procedures, determine if the local Expected Receive Section Trace Format and Expected Receive Section Trace Value parameters are provisioned correctly.


6

Are the local Expected Receive Section Trace Format and Expected Receive Section Trace Value parameters provisioned correctly?

If ...

Then...

No,

Select Configuration → Equipment to access the required port and provision the Expected Receive Section Trace Format and/or Expected Receive Section Trace Value parameters with the correct values. Then continue with Step 7.

Reference:

Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) User Operations Guide, 365-372-325

Yes,

Then proceed to Step 9.


7

From the System View, click the Alarm List button and click Refresh.


8

Is the inc. section trace identifier mismatch alarm still present?

If...

Then...

Yes

Continue with Step 9.

No

STOP! End of Procedure.


9

Using local procedures, notify personnel at the site supplying the signal to verify/change the Transmit Section Trace Format and/or Transmit Section Trace Value parameters as required.


10

From the System View, click the Alarm List button and click Refresh.


11

Is the inc. section trace identifier mismatch alarm still present?

If...

Then...

Yes

Continue with Step 12.

No

STOP! End of Procedure.


12

Important!

A likely cause of the inc. section trace identifier mismatch alarm at the local network element is a mis-connection or a problem with the cabling/wiring between systems.

Follow local procedures to isolate and clear the trouble.


End of steps