Procedure 5-114: Clear "VCG Failure of LCAS Protocol" alarms

- Overview

Use this procedure to clear the following alarms:

  • VCG Failure of LCAS Protocol (Sink)

  • VCG Failure of LCAS Protocol (Source)

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.

Steps

Complete the following steps to clear a VCG Failure of LCAS Protocol alarm.

 
1

From the System View, select Configuration → Equipment. Expand the required Ethernet circuit pack details and select the affected VCG port. Click Select.


2

Select the LCAS tab and disable the LCAS mode. Click Apply.

Result:

A dialog box appears asking you to confirm executing this command. Click Yes.


3

Re-enable the LCAS mode and click Apply.

Result:

A dialog box appears asking you to confirm executing this command. Click Yes. Click Close to exit window.


4

From the System View, click the Alarm List button and click Refresh.


5

Is the VCG Failure of LCAS Protocol alarm still present?

If...

Then...

Yes

Continue with the next step.

No

STOP! End of Procedure.


6

Use the WaveStar® CIT to log in to the far-end Alcatel-Lucent 1665 DMXtend.

Reference:

Procedure 6-2: Connect Personal Computer (PC) and establish WaveStar® CIT session


7

At the far end, repeat Step 1 through Step 5, as required.


End of steps