Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear an Automatic protection switch mode mismatch alarm.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the Automatic protection switch mode mismatch alarm in the resulting alarm list and note the corresponding AID. | ||||||
2 |
Refer to office records to determine the correct provisioning for the port Application parameter of the applicable optical port pair. (The port Application parameter of the applicable local optical port pair is currently provisioned Bidirectional 1+1.) | ||||||
3 |
To clear the Automatic protection switch mode mismatch alarm either change the port Application parameter of the applicable local port pair or change the port Application parameter of the applicable far-end port pair according to office records and local procedures.
| ||||||
4 |
From the System View, select Configuration → Equipment. Expand the required circuit pack. Select the required port and click Select. Result: The port provisionable parameters appear. | ||||||
5 |
Provision the port Application parameter according to office records and click Apply and Close. | ||||||
6 |
From the System View, click the Alarm List button and click Refresh. Result: The Automatic protection switch mode mismatch alarm is no longer present. End of steps |