Procedure 5-13: Clear "CP software upgrade required" condition

- Overview

This procedure is used to clear a CP software upgrade required condition.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Electrostatic discharge in Chapter 1, Safety.

Steps

Complete the following steps to clear a CP software upgrade required condition.

 
1

From the WaveStar® CIT System View, click the Alarm List button and locate the CP software upgrade required alarm in the resulting alarm list.


2

Refer to the Probable Cause column in the alarm list, and note the corresponding AID.


3

Un-seat and then re-seat the alarmed circuit pack.

Result:

SYSCTL reinitializes the pack and should automatically update the firmware on the newly installed pack.


4

From the WaveStar® CIT System View, click the Alarm List and Refresh buttons.


5

Is the CP software upgrade required alarm still present?

If...

Then...

Yes

Continue with Step 6.

No

STOP! End of Procedure.


6

From the System View, select Configuration → Software → Apply Software to schedule a Smart or Smart, Override Alarms software apply.

Result:

Approximately 15 minutes after the scheduled apply time, the apply is complete. You will be logged off the system when the system resets.

A flashing b in the IND display on the SYSCTL indicates that a boot is in progress. During the boot, the b may extinguish for up to 20 seconds and then resume flashing.

Reference:

Procedure 6-20: Apply software generic


7

Log back into the shelf.


8

From the WaveStar® CIT System View, click the Alarm List and Refresh buttons.


9

Is the CP software upgrade required alarm still present?

If...

Then...

Yes

Continue with the next step.

No

STOP! End of Procedure.


10

From the System View, select Configuration → Software → Apply Software to schedule a Forced software apply.

Result:

Approximately 15 minutes after the scheduled Forced apply time, the apply is complete. You will be logged off the system when the system resets.

A flashing b in the IND display on the SYSCTL indicates that a boot is in progress. During the boot, the b may extinguish for up to 20 seconds and then resume flashing.

Reference:

Procedure 6-20: Apply software generic


11

Log back into the shelf.


12

From the WaveStar® CIT System View, click the Alarm List and Refresh buttons.

If the CP software upgrade required alarm is still present, you may need to replace the pack. Contact your next level of support.


End of steps