Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear a CP not allowed - crs alarm.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the CP not allowed - crs alarm in the resulting alarm list. | ||||||
2 |
Determine the alarm level(s) for the active CP not allowed - crs alarm(s). Clear the alarms in order of severity. | ||||||
3 |
Refer to the Probable Cause column in the alarm list, determine the affected circuit pack, and note the corresponding slot AID. | ||||||
4 |
Select Reports → Equipment Lists → Pack. Click Shelf and Select to obtain the Circuit Pack List. Observe the correct circuit pack information for the required slot. | ||||||
5 |
Compare the correct circuit pack information from the Circuit Pack List with the circuit pack that is physically in the required slot.
End of steps |