Procedure 5-11: Clear "CP not allowed - eqpt" alarm

- Overview

This procedure is used to clear a CP not allowed - eqpt alarm.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.

Steps

Complete the following steps to clear a CP not allowed - eqpt alarm.

 
1

From the WaveStar® CIT System View, click the Alarm List button and locate the CP not allowed - eqpt alarm in the resulting alarm list.


2

Determine the alarm level(s) for the active CP not allowed - eqpt alarm(s). Clear the alarms in order of severity.


3

Refer to the Probable Cause column in the alarm list, determine the affected circuit pack, and note the corresponding slot AID.


4

Using office records, determine the correct circuit pack type for the required slot.


5

From the System View, select Reports → Equipment Lists → Pack. Select Shelf and click Select to obtain the Circuit Pack List. Observe the circuit pack information for the required slot.


6

Compare the correct circuit pack information from office records with the circuit pack information from the Circuit Pack List and the circuit pack that is physically in the required slot.


7

Is the correct circuit pack physically installed in the required slot?

If ...

Then...

Yes,

Select Configuration → Update System → Update Inventory.

A dialog box appears asking you to confirm executing this command. Click Yes.

No,

Perform the following:

  1. Obtain the correct type of circuit pack (according to office records and the Circuit Pack List) for the required slot.

  2. Replace the wrong circuit pack currently in the required slot with the correct circuit pack. Refer to the appropriate circuit pack replacement procedure in Chapter 6, Supporting procedures.


End of steps