Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear an inc. LOS alarm.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the inc. LOS alarm in the resulting alarm list. | ||||||
2 |
Refer to the Probable Cause column in the alarm list, determine the affected circuit pack affected, and note the corresponding AID. | ||||||
3 |
Using office records, determine if the Data port is supposed to be in service.
| ||||||
4 |
Check local fiber/cable connections between the Data port and the interconnecting equipment for faulty connections or damage and clean/repair/replace as necessary. Reference: Procedure 6-11: Clean optical fibers, dual LC adapters and LC lightguide buildouts (LBOs) | ||||||
5 |
From the System View, click the Alarm List button and click Refresh. | ||||||
6 |
Is the inc. LOS alarm still present?
| ||||||
7 |
Important! A likely cause of the alarm is a failure at the interfacing customer Data equipment or a problem with fiber/cable between the local Data port and the interfacing customer Data equipment. Follow local procedures to isolate and clear the trouble. | ||||||
8 |
From the System View, click the Alarm List button and click Refresh. If the inc. LOS alarm is still present, contact your next level of support. End of steps |