Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Electrostatic discharge in Chapter 1, Safety.
Select View → Equipment to determine if the Main slots are equipped with Very Large Fabric circuit packs.
Complete the following steps to clear an inc. DS1/E1 sync. ref alarm.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the inc. DS1/E1 sync. ref alarm in the resulting alarm list and note the corresponding AID. | ||||||||
2 |
Is the alarm inc. DS1 sync. ref. EOOF?
| ||||||||
3 |
Is the alarm inc. DS1/E1 sync. ref. OOL?
| ||||||||
4 |
Is the alarm inc. E1 sync. ref. CRC-4 MFA mismatch?
| ||||||||
5 |
To clear the inc. E1 sync. ref. CRC-4 MFA mismatch alarm, either change the format of the incoming E1 synchronization reference signal to CRC-4 or change the format of the local E1 timing input port to FAS (Frame Alignment Signal) according to local procedures.
STOP! End of Procedure. | ||||||||
6 |
Important! Perform the following to clear inc. sync. ref. AIS, inc. DS1/E1 sync. ref. BER, inc. DS1/E1 sync. ref. LOF, and inc. DS1/E1 sync. ref. LOS alarms. This also includes inc. DS1/E1 sync. ref. OOL alarms (VLF mains only). Visually check the incoming signal cables and connections and correct any problems found. If a visual inspection does not reveal any problems, you may consider making electrical measurements per local procedures. | ||||||||
7 |
From the System View, click the Alarm List button and click Refresh. | ||||||||
8 |
Is the inc. DS1/E1 sync. ref alarm still present?
| ||||||||
9 |
Follow local procedures to isolate and repair the trouble. End of steps |