Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear an inc. FE-LAN ANM alarm.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the inc. FE-LAN ANM alarm in the resulting alarm list. | ||||||
2 |
Refer to the Probable Cause column in the alarm list, determine the affected circuit pack, and note the corresponding AID. | ||||||
3 |
From the System View, select View → Equipment, expand the required circuit pack, highlight the alarmed port, and click Select. Then click the Port Data tab. Result: The port parameters appear. The port parameters vary according to the circuit pack. | ||||||
4 |
Record the following information: | ||||||
5 |
From the View Equipment window, click Flow Control tab. Result: The flow control parameters appear. | ||||||
6 |
Record the following information: Click Close. | ||||||
7 |
Follow local procedures and determine the provisioned and actual (operational) duplex mode, line rate, and flow control mode at the interfacing customer LAN port. | ||||||
8 |
Does the actual (operational) duplex mode, line rate, and flow control mode match on both the local LAN port and the interfacing customer LAN port?
| ||||||
9 |
Follow local procedures to determine if provisioning changes are required at the local LAN port or the interfacing customer LAN port.
| ||||||
10 |
Do the actual (operational) duplex mode and line rate match on both the local LAN port and the interfacing customer LAN port?
| ||||||
11 |
From the System View select Configuration → Equipment, expand the required circuit pack, highlight the desired port, and click Select. Then click the Port Data tab. Result: The port parameters appear. | ||||||
12 |
Provision the Provisioned Duplex Mode and/or Line Rate parameters as required to match the interfacing customer LAN port and click Apply. Result: A warning message appears asking you to confirm executing this command. Click Yes. | ||||||
13 |
Does the actual (operational) flow control modes match on both the local LAN port and the interfacing customer LAN port?
| ||||||
14 |
From the System View, select Configuration → Equipment, expand the required circuit pack, highlight the desired port and click Select. Then click the Flow Control tab. Result: The flow control parameters appear. | ||||||
15 |
Provision the Flow Control Mode parameter as required to match the interfacing customer LAN port and click Apply. Result: A warning message appears asking you to confirm executing this command. Click Yes. | ||||||
16 |
From the System View, click the Alarm List button and click Refresh. | ||||||
17 |
Is the inc. FE-LAN ANM alarm still present?
| ||||||
18 |
From the System View select Configuration → Equipment, expand the required circuit pack, highlight the desired port, and click Select. Then click the Port Data tab. Result: The port parameters appear. | ||||||
19 |
Disable the Auto-Negotiation parameter and click Apply. Then Enable the Auto-Negotiation parameter and click Apply. | ||||||
20 |
From the System View, click the Alarm List button and click Refresh. If the inc. FE-LAN ANM alarm is still present, contact your next level of support. End of steps |