Procedure 5-108: Clear "SYS generic corrupted" alarm

- Overview

This procedure is used to clear a SYS generic corrupted alarm.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Electrostatic discharge in Chapter 1, Safety.

Steps

Complete the following steps to clear a SYS generic corrupted alarm.

 
1

Important!

The software apply operation has been interrupted/failed.

From the System View, select Configuration → Software → Apply Software to reschedule another Smart or Smart, Override Alarms software apply.

Result:

Approximately 15 minutes after the scheduled Smart apply time, the apply is complete. You will be logged off the system when the system resets.

A flashing b in the IND display on the SYSCTL indicates that a boot is in progress. During the boot, the b may extinguish for up to 20 seconds and then resume flashing.

Reference:

Procedure 6-20: Apply software generic


2

Did the software apply operation complete successfully?

If...

Then...

Yes

Proceed to Step 5.

No

Continue with the next step.


3

From the System View, select Configuration → Software → Apply Software to schedule a Forced software apply.

Result:

Approximately 15 minutes after the scheduled Forced apply time, the apply is complete. You will be logged off the system when the system resets.

A flashing b in the IND display on the SYSCTL indicates that a boot is in progress. During the boot, the b may extinguish for up to 20 seconds and then resume flashing.

Reference:

Procedure 6-20: Apply software generic


4

Did the Forced software apply operation complete successfully?

If...

Then...

Yes

Proceed to Step 5.

No

Contact your next level of support.


5

When the system reset is complete, log back into the network element.

Reference:

Procedure 6-2: Connect Personal Computer (PC) and establish WaveStar® CIT session


End of steps