Procedure 5-36: Clear "Generic/Database/Equipment Configuration" alarms/conditions

- Overview

This procedure is used to clear the following generic, database, and equipment configuration alarms/conditions:

  • Equipment configuration no longer supported

  • Invalid Database

  • Maintenance Mode

  • Multiple Databases

  • Multiple Generics

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Electrostatic discharge in Chapter 1, Safety.

  3. Obtain office records specifying the required valid generic.

  4. Locate the most recent backup copy of the network element database in case it is necessary to restore the network element database.

Steps

Complete the following steps to clear generic, database, and equipment configuration alarms/conditions.

 
1

Important!

When the network element is in the Maintenance Mode state, the IND display on the SYSCTL circuit pack faceplate shows MPx.x (where x.x is the generic number).

If the network element is in the Maintenance Mode state, the default User IDs/passwords must be used to log in to the network element. LUC01, LUC02, and LUC03 are the default privileged User IDs, and DMXTND2.5G is the default privileged password.

Perform the following to log in to the network element using the WaveStar® CIT TL1 Cut-Tthrough Mode.

  1. From the Network View, log into the NE but this time click TL1, not Graphical.

  2. Select the Cut Through Execution Mode and click OK.

  3. Enter a default privileged User ID and password. Defaults are LUC01 and DMXTND2.5G, respectively.

Reference:

Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) TL1 Message Details, 365-372-328


2

Execute the rtrv-alm-all TL1 command to obtain a list of active alarms.

Reference:

Alcatel-Lucent 1665 Data Multiplexer Extend (DMXtend) TL1 Message Details, 365-372-328


3

Observe the list of active alarms.

If...

Then...

Invalid Database, Multiple Databases, and/or Multiple Generics alarms are listed,

Execute the canc-user TL1 command to log out of the network element, then proceed to Procedure 5-36.1: Clear "Generic/Database" alarms.

Equipment configuration no longer supported alarm is listed,

Execute the canc-user TL1 command to log out of the network element, then proceed to Procedure 5-36.2: Clear "Equipment configuration no longer supported" alarm.


End of steps