Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear an inc. VT alarm.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the inc. VT alarm in the resulting alarm list. | ||||||
2 |
Determine the alarm level(s) for the active inc. VT alarm(s). Clear the alarms in order of severity. | ||||||
3 |
Refer to the Probable Cause column in the alarm list, determine the affected circuit pack, and note the corresponding AID. | ||||||
4 |
Note the source address of the VT alarm/condition reported (for example, m1-1-1-1-1). Based on the circuit layout or other office records, determine the other shelf where that time slot is supposed to be originated (cross-connected to a DS1 termination). | ||||||
5 |
Log in to the originating shelf. Reference: Procedure 6-2: Connect Personal Computer (PC) and establish WaveStar® CIT session | ||||||
6 |
From the System View, select the View → Cross-Connections. | ||||||
7 |
Are there incomplete or incorrect cross-connections?
| ||||||
8 |
From the System View, select Configuration → Cross-Connections to access the Cross-Connection Wizard and perform the required provisioning. | ||||||
9 |
From the System View, click the Alarm List button and click Refresh. | ||||||
10 |
Is the inc. VT alarm still present?
| ||||||
11 |
One at a time, log in to every shelf where pass-through cross-connections exist for the service (for example, m1-1-1-1-1 to m2-1-1-1-1 for VT1.5). Select the View → Cross-Connections command from the System View at each shelf to determine if the time slot identified in Step 4 is cross-connected as specified in circuit layout or other office records. | ||||||
12 |
At any shelves with missing cross-connections, select Configuration → Cross-Connections to access the Cross-Connection Wizard and provision the correct pass-through cross-connection (for example, m1-1-1-1-1 to m2-1-1-1-1 for VT1.5). | ||||||
13 |
From the System View, click the Alarm List button and click Refresh. | ||||||
14 |
Is the inc. VT alarm still present?
| ||||||
15 |
Check the optical signal level and clean the cable ends if needed. If no problem is found, check the line build-outs (LBOs). Reference: Procedure 6-11: Clean optical fibers, dual LC adapters and LC lightguide buildouts (LBOs) | ||||||
16 |
From the System View, click the Alarm List button and click Refresh. | ||||||
17 |
Is the inc. VT alarm still present?
| ||||||
18 |
Is the OLIU circuit pack equipped with pluggable transmission modules?
| ||||||
19 |
Disconnecting cables and/or replacing pluggable transmission modules may disrupt service. Before taking action, determine the extent of service disruption caused by disconnecting cables or replacing a pluggable transmission module. Then, perform the action(s) deemed appropriate in light of the traffic being carried and the nature of the failure. Replace the affected local pluggable transmission module. Reference: Procedure 6-5: Replace pluggable transmission module | ||||||
20 |
From the System View, click the Alarm List button and click Refresh. | ||||||
21 |
Is the inc. VT alarm still present?
| ||||||
22 |
Disconnecting cables and/or replacing circuit packs may disrupt service. Before taking action, determine the extent of service disruption caused by disconnecting cables or replacing a circuit pack. Then, perform the action(s) deemed appropriate in light of the traffic being carried and the nature of the failure. Replace the terminating OCN OLIU circuit pack. Reference: End of steps |