Procedure 5-54: Clear "inc. line sync. ref. OOL" alarm

- Overview

This procedure is used to clear the inc. line sync. ref. OOL alarm.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.

  3. Select View → Equipment to determine if the Main slots are equipped with Very Large Fabric circuit packs.

Steps

Complete the following steps to clear inc. line sync. ref. OOL alarm.

 
1

From the WaveStar® CIT System View, click the Alarm List button, locate the inc. line sync. ref. OOL alarm in the resulting alarm list.


2

Refer to the Probable Cause column (SYNCOOS or SYNC) in the alarm list, determine the affected OC-N line, and note the corresponding AID.


3

Are there any inc. OCN alarms present in the alarm list?

If...

Then...

Yes,

Proceed to the appropriate procedure to clear each alarm in order of severity. Then continue with the next step.

No,

Proceed to Step 7.


4

If the Main slots are equipped with non-VLF circuit packs, select Configuration → Update System → Update Reference.

Result:

A dialog box appears asking you to confirm executing this command. Click Yes.


5

From the System View, click the Alarm List button and click Refresh.


6

Is the inc. line sync. ref. OOL alarm still present?

If...

Then...

Yes

Continue with the next step.

No

STOP! End of Procedure.


7

Important!

A possible cause of the alarm at the local node is a synchronization problem at the far-end (upstream) node that causes the TX interfaces (at the far-end node) to transmit off frequency.

Using office records, identify and log in to the far-end SONET network element supplying the optical signal.

Reference:

Procedure 6-2: Connect Personal Computer (PC) and establish WaveStar® CIT session


8

Follow local procedures for addressing synchronization- and OCN-related conditions/alarms at the far-end SONET network element.


9

If the Main slots are equipped with non-VLF circuit packs at the local node, select Configuration → Update System → Update Reference.

Result:

A dialog box appears asking you to confirm executing this command. Click Yes.


10

From the System View at the local node, click the Alarm List button and click Refresh.


11

Is the inc. line sync. ref. OOL alarm still present?

If...

Then...

Yes

Continue with the next step.

No

STOP! End of Procedure.


12
DANGER 

NOTICE

Service-disruption hazard

Disconnecting cables and/or replacing circuit packs may disrupt service.

Before taking action, determine the extent of service disruption caused by disconnecting cables or replacing a circuit pack. Then, perform the action(s) deemed appropriate in light of the traffic being carried and the nature of the failure.

Replace the affected local OC-N OLIU circuit pack.

Reference:


13

If the Main slots are equipped with non-VLF circuit packs, select Configuration → Update System → Update Reference.

Result:

A dialog box appears asking you to confirm executing this command. Click Yes.


14

From the System View, click the Alarm List button and click Refresh.


15

Is the inc. line sync. ref. OOL alarm still present?

If...

Then...

Yes

Remove the replacement OC-N OLIU circuit pack and return the original circuit pack to the slot, then contact your next level of support.

No

STOP! End of Procedure.