Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear inc. OTS LOS-P alarm.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the inc. OTS LOS-P alarm in the resulting alarm list. | ||||||
2 |
Refer to the Probable Cause column in the alarm list, determine the affected OTS line, and note the corresponding AID. | ||||||
3 |
Visually check the local receive fiber connections between the circuit pack faceplate and the LGX panel or equivalent connection point for faulty connections or damage.
| ||||||
4 |
From the System View, click the Alarm List button and click Refresh. | ||||||
5 |
Is the inc. OTS LOS-P alarm still present?
| ||||||
6 |
Disconnecting cables and/or replacing circuit packs may disrupt service. Before taking action, determine the extent of service disruption caused by disconnecting cables or replacing a circuit pack. Then, perform the action(s) deemed appropriate in light of the traffic being carried and the nature of the failure. Replace the affected local OMD circuit pack. Reference: Procedure 6-28: Replace DWDM optical multiplexer/demultiplexer circuit pack | ||||||
7 |
From the System View, click the Alarm List button and click Refresh. | ||||||
8 |
Is the inc. OTS LOS-P alarm still present?
| ||||||
9 |
Important! At this point, the local network element is operating correctly. The trouble is in the far-end network element or in the fiber/cable between the far-end network element and the local network element. Follow local procedures for addressing OTS-related conditions/alarms at the far-end network element. | ||||||
10 |
From the System View at the local network element, click the Alarm List button and click Refresh. | ||||||
11 |
Is the inc. OTS LOS-P alarm still present?
End of steps |
November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |