Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear an unexpected CP type alarm.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the unexpected CP type alarm in the resulting alarm list. | ||||||
2 |
Determine the alarm level(s) for the active unexpected CP type alarm(s). Clear the alarms in order of severity. | ||||||
3 |
Refer to the Probable Cause column in the alarm list, and note the corresponding slot AID. | ||||||
4 |
Using office records, determine the correct circuit pack type for the required slot. | ||||||
5 |
Compare the correct circuit pack type from office records with the circuit pack that is physically in the required slot. | ||||||
6 |
Is the correct circuit pack type physically installed in the required slot?