Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear a neighbor SYSCTL CP unavailable (nbr tid = TID) alarm.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the neighbor SYSCTL CP unavailable (nbr tid = TID) alarm and the section DCC failed alarm in the resulting alarm list. | ||||||
2 |
Refer to the Probable Cause column in the alarm list, determine the affected the circuit pack, and note the corresponding AID. | ||||||
3 |
Refer to the Description column in your alarm list, and note the nbr tid = TID (neighbor target identifier = LT-DMXTEND [default]). Important! If the nbr tid = UNKNOWN, consult your network diagrams and/or local procedures and determine the TID of the remote node that is connected to the affected OLIU. | ||||||
4 |
Log in to the neighboring NE (using its TID) via TCP/IP or OSI or dispatch local craft to the remote site and login serially. Reference: Procedure 6-2: Connect Personal Computer (PC) and establish WaveStar® CIT session | ||||||
5 |
Are you successfully logged into the remote shelf?
| ||||||
6 |
From the System View of the remote shelf, click the Alarm List button. | ||||||
7 |
Is there section DCC channel failed alarm or inc. OCN alarm present?
| ||||||
8 |
From the System View of the remote NE, click the Alarm List button and click Refresh. | ||||||
9 |
Is the section DCC channel failed alarm or the inc. OCN alarm(s) still present?
| ||||||
10 |
From the System View of the local NE (the NE indicating the neighbor SYSCTL CP unavailable (nbr tid = TID) alarm), click the Alarm List button and click Refresh. | ||||||
11 |
Is the neighbor SYSCTL CP unavailable (nbr tid = TID) or the section DCC channel failed alarm still present?
End of steps |