You must log in as a Privileged, General, Maintenance, or Reports Only user to view performance monitoring reports.
Prior to performing this procedure, refer to Before you begin and Required equipment in this chapter.
Perform the following steps to view PM reports.
1 |
From the System View menu, select Performance → View PM Reports then select the entity you want to report. Result: The ( ) PM Report window opens for the selected entity; or, if Performance → View PM Reports → TCA was selected, the TCA report is displayed automatically. Proceed to Step 6. |
2 |
Expand the details for the required circuit pack and port (if necessary). Highlight the required entity and click Select. Result: A parameter selection details window opens. |
3 |
Select the Time Period (1 Day or 15 Min) as required. |
4 |
Select the Monitored Date, Monitor Time (15-Minute Time Period only), and Monitor Level parameters for the report you want, if required. |
5 |
Important! The following menu selections do not display Near End and Far End tabs because far-end performance monitoring is not supported. The parameters that are available for selection are near-end PM parameters. If required, select the Near End and/or Far End Tab as required and select the parameters to reported. Click Apply. Result: The ( ) PM Report is displayed. If you selected parameters on both tabs, the resulting report includes parameters designated as NEND (Near End) and FEND (Far End). |
6 |
View the parameter values. Click Close to exit. End of steps |
Copyright © 2011 Alcatel-Lucent. All rights reserved. |