Procedure 5-12: Clear "CP removed or CP failure" alarm

- Overview

This procedure is used to clear a CP removed or CP failure alarm.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.

Steps

Complete the following steps to clear a CP removed or CP failure alarm.

 
1

From the WaveStar® CIT System View, click the Alarm List button and locate the CP removed or CP failure alarm in the resulting alarm list.


2

Determine the alarm level(s) for the active CP removed or CP failure alarm(s). Clear the alarms in order of severity.


3

Refer to the Probable Cause column in the alarm list and note the corresponding slot AID.


4

Important!

The CP removed or CP failure alarm is reported when a circuit pack is removed from a slot and when a slot is equipped with a circuit pack that has a failed power module.

Locate the required slot and determine if a circuit pack is physically present in the required slot.


5

Is a circuit pack physically present in the required slot?

If...

Then...

Yes,

Replace the failed circuit pack in the required slot. Refer to the appropriate circuit pack replacement procedure in Chapter 6, Supporting procedures.

STOP! End of Procedure.

No,

Continue with Step 6.


6

Using office records, determine if the required slot should contain a circuit pack.


7

Do office records show that the required slot should contain a circuit pack?

If...

Then...

Yes,

Obtain the missing circuit pack and install it into the required slot.

Refer to the appropriate circuit pack installation procedure in the Alcatel-Lucent 1850 Transport Service Switch (TSS-5) User Provisioning Guide.

No,

Perform the following:

  1. Use View → Cross-Connections to obtain a current list of cross-connections. If required, use Configuration → Cross-Connections to access the Cross-Connection Wizard and delete any cross-connections to the affected circuit pack.

  2. Select Configuration → Update System → Update All.

    A dialog box appears asking you to confirm executing this command. Click Yes.


End of steps