Procedure 5-18: Clear "environmentn" alarm

- Overview

This procedure is used to clear an environmentn alarm.

- Before you begin

Prior to performing this procedure, refer to Before you begin and Required equipment in this chapter.

Steps

Complete the following steps to clear an environmentn alarm/condition.

 
1

From the WaveStar® CIT System View, click on the Alarm List button and locate the environmentn alarm/condition in the resulting alarm list.


2

Determine the alarm level(s) for the active environmentn alarm(s). Clear the alarms in order of severity.


3

Refer to the Probable Cause column in the alarm list, and note the corresponding AID.


4

From the System View, select View → Misc. Discretes and expand Input.

Result:

The View Miscellaneous Discretes window opens.


5

Can you clearly identify the cause of the condition?

If...

Then...

Yes

Clear using local procedures.

STOP! End of Procedure.

Yes; Environment 5 is fan failure

Proceed to Procedure 5-19: Clear "fan shelf failed" or "hardware failure" alarm.

No

Contact your next level of support.


End of steps

Copyright © 2011 Alcatel-Lucent. All rights reserved.