Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear a SYS generic corrupted alarm.
1 |
Important! The software apply operation has been interrupted/failed. From the System View, select Configuration → Software → Apply Software to reschedule another Smart (without Override) or Smart (with Override) software apply. Result: Approximately 15 minutes after the scheduled Smart apply time, the apply is complete. You will be logged off the system when the system resets. Reference: Procedure 6-9: Apply software generic | ||||||
2 |
Did the software apply operation complete successfully?
| ||||||
3 |
From the System View, select Configuration → Software → Apply Software to schedule a Forced software apply. Result: Approximately 15 minutes after the scheduled Forced apply time, the apply is complete. You will be logged off the system when the system resets. Reference: Procedure 6-9: Apply software generic | ||||||
4 |
Did the Forced software apply operation complete successfully?
| ||||||
5 |
When the system reset is complete, log back into the network element. Reference: Procedure 6-2: Connect personal computer (PC) and establish WaveStar® CIT session End of steps |