Procedure 5-67: Clear "version mismatch" alarm

- Overview

This procedure is used to clear a version mismatch alarm.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Electrostatic discharge in Chapter 1, Safety.

Complete the following steps to clear a version mismatch alarm.

 
1

From the WaveStar® CIT System View, click the Alarm List button and locate the version mismatch alarm in the resulting alarm list.


2

Refer to the Probable Cause column in the alarm list, determine the circuit pack affected, and note the corresponding AID.


3

Un-seat and then re-seat the alarmed circuit pack.

Result:

SYSCTL reinitializes the pack and should automatically update the firmware on the newly installed pack.


4

From the System View, click the Alarm List button and click Refresh.


5

Is the version mismatch alarm still present?

If...

Then...

Yes

Continue with Step 6.

No

STOP! End of procedure.


6

From the System View menu, select Configuration → Software → Apply Software to schedule a Smart (without Override) or Smart (with Override) software apply.

Result:

Approximately 15 minutes after the scheduled apply time, the apply is complete. You will be logged off the system when the system resets.

Reference:

Procedure 6-9: Apply software generic


7

Log back into the shelf.

Reference:

Procedure 6-2: Connect personal computer (PC) and establish WaveStar® CIT session


8

From the System View, click the Alarm List button and click Refresh.


9

Is the version mismatch alarm still present?

If...

Then...

Yes

Continue with Step 10.

No

STOP! End of Procedure.


10

From the System View menu, select Configuration → Software → Apply Software to schedule a Forced software apply.

Result:

Approximately 15 minutes after the scheduled apply time, the apply is complete. You will be logged off the system when the system resets.

Reference:

Procedure 6-9: Apply software generic


11

Log back into the shelf.

Reference:

Procedure 6-2: Connect personal computer (PC) and establish WaveStar® CIT session


12

From the System View, click the Alarm List button and click Refresh.


13

Is the version mismatch alarm still present?

If...

Then...

Yes

Continue with the next step.

No

STOP! End of Procedure.


14

Un-seat and then re-seat the SYSCTL circuit pack, then repeat this task from Step 6.


End of steps