The system has detected STMN multiplex section (MS) alarm indication signal (AIS) on an incoming STMN line.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Default SA: Critical (CR) Default NSA: Not Alarmed (NA) |
AID Type |
STMN Line |
Date |
Month/day/year that condition was detected |
Time |
Hour:minute:second that condition was detected |
Probable Cause |
AIS (AIS Detected) |
Effect on Service |
SA or NSA |
Alarm Entity Type |
STM1 STM4 STM16 |
Description |
inc. STM1 MS-AIS inc. STM4 MS-AIS inc. STM16 MS-AIS |
Likely Cause |
The STMN OLIU circuit pack failed at the far-end network element. |
Visible Indication |
Lighted CR/MJ or MN/ABN LED on SYSCTL faceplate and a flashing FAULT LED on the alarmed circuit pack. |
Action |
Proceed to Procedure 5-36: Clear "inc. OCN/STMN" conditions/alarms. |