Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear inc. OCN/STMN alarms.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the inc. OCN/STMN alarm in the resulting alarm list. | ||||||
2 |
Determine the alarm level(s) for the active inc. OCN/STMN alarm(s). Clear the alarms in order of severity. | ||||||
3 |
Refer to the Probable Cause column in the alarm list, determine the affected OC-N/STM-N line, and note the corresponding AID. | ||||||
4 |
Visually check the local receive fiber connections between the circuit pack faceplate/pluggable transmission module and the LGX panel or equivalent connection point for faulty connections or damage.
| ||||||
5 |
From the System View, click the Alarm List button and click Refresh. | ||||||
6 |
Is the inc. OCN/STMN alarm still present?
| ||||||
7 |
Disconnecting cables and/or replacing pluggable transmission modules may disrupt service. Before taking action, determine the extent of service disruption caused by disconnecting cables or replacing a pluggable transmission module. Then, perform the action(s) deemed appropriate in light of the traffic being carried and the nature of the failure. Replace the affected local pluggable transmission module. Reference: Procedure 6-6: Replace pluggable transmission module | ||||||
8 |
From the System View, click the Alarm List button and click Refresh. | ||||||
9 |
Is the inc. OCN/STMN alarm still present?
| ||||||
10 |
Disconnecting cables and/or replacing circuit packs may disrupt service. Before taking action, determine the extent of service disruption caused by disconnecting cables or replacing a circuit pack. Then, perform the action(s) deemed appropriate in light of the traffic being carried and the nature of the failure. Replace the affected local circuit pack. Reference: Procedure 6-4: Replace VLNC5x SONET/SDH transport circuit pack | ||||||
11 |
From the System View, click the Alarm List button and click Refresh. | ||||||
12 |
Is the inc. OCN/STMN alarm still present?
| ||||||
13 |
Important! At this point, the local network element is operating correctly. The trouble is in the far-end network element or in the fiber/cable between the far-end network element and the local network element. Follow local procedures for addressing OCN/STMN-related conditions/alarms at the far-end network element. | ||||||
14 |
From the System View at the local network element, click the Alarm List button and click Refresh. | ||||||
15 |
Is the inc. OCN/STMN alarm still present?
| ||||||
16 |
Follow local procedures to isolate and clear the fiber/cable trouble between the far-end network element and the local network element. End of steps |