The system has detected a loss-of-signal (LOS) condition on the STMN line.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Minor (MN) SA: Critical (CR) NSA: Minor (MN) |
AID Type |
STMN Line |
Date |
Month/day/year that condition was detected |
Time |
Hour:minute:second that condition was detected |
Probable Cause |
LOS (Loss of Signal) |
Effect on Service |
SA or NSA |
Alarm Entity Type |
STM1 STM4 STM16 |
Description |
inc. STM1 LOS inc. STM4 LOS inc. STM16 LOS |
Likely Cause |
The STMN OLIU circuit pack/pluggable transmission module failed at the near end, the receive fiber failed, or the OLIU circuit pack failed at the far end. An unprotected line/port carrying service failed: SA. A protected line/port failed: NSA. |
Visible Indication |
Lighted CR/MJ or MN/ABN LED on SYSCTL faceplate and a flashing FAULT LED on the alarmed circuit pack. |
Action |
Proceed to Procedure 5-36: Clear "inc. OCN/STMN" conditions/alarms. |