Use this procedure to assign the TCA Profile for the ETS InFlow ID.
This screen also displays the detailed content of the selected TCA Profile at the bottom of the Assignment screen. When the selected TCA Profile is changed, the detailed TCA Profile content is modified as well.
There are four default TCA Profiles for all ETS InFlows.
Obtain the work instructions for this procedure.
1 |
Log in to the VLNC42B circuit pack being provisioned. |
2 |
From the Navigation menu, select ETS Flow Services → Performance Monitoring → TCA Profile Assignment. Result: The ETS TCA Profile Assignment screen appears. |
3 |
Enter the required parameters, then click Submit to assign/display the TCA Profile for the selected ETS InFlow. Reference: ETS TCA Profile Assignment parameters. End of steps |
Parameter |
Value |
SNMP |
---|---|---|
ETS Flow ID |
The ETS InFlow ID. A drop-down list containing all ETS InFlows in the system. |
OpticsIMETSIn- FlowIndex |
Time Period |
This parameter identifies the accumulation time period for performance monitoring data (1-DAY or 15-minute collection register). Valid values: 15-MIN or 1-DAY. |
enhEtsIn- FlowCDGranularityPeriod |
TCA Profile |
This parameter specifies which TCA Profile to be applied to the selected ETS InFlow ID. Valid values: an integer value in the range of 0 to 3. |
enhEtsIn- FlowCDThresholdDataInstance |
Displayed Threshold Data | ||
Monitor Type |
Monitored PM parameter. EINFg (Total Green Packets Received w/o Error) — The number of green frames (packets) received with error by the Virtual Ethernet Interface EINFr (Total Red Packets Received w/o Error) — The number of Red frames (packets) received without error by the Virtual Ethernet Interface. |
|
Threshold Enable |
The field indicates whether or not the threshold is enabled. |
|
Low Threshold (Clear) |
Lowest Threshold value for the monitored PM paramter. |
|
High Threshold (Raise) |
Highest Threshold value for the monitored PM paramter. |