Obtain the work instructions for this procedure.
1 |
Log in to the VLNC42B circuit pack being provisioned. |
2 |
From the Navigation menu, select ETS Flow Services → Performance Monitoring → PM Report. Result: The ETS PM Report screen appears. |
3 |
Enter the required parameters, then click Submit to update the PM State for the selected ETS InFlow. If required, click Clear All Counters to clear all PM current data for the selected ETS Flow and Monitor Period. Reference: End of steps |
Parameter |
Value |
SNMP |
---|---|---|
Control Options | ||
ETS Flow ID |
This is a drop-down list containing all ETS InFlows that have at least one PM Mode enabled. |
OpticsIMETSIn- FlowIndex |
Monitor Type |
Monitored counter type. It identifies the type of monitored registers that are being retrieved. ALL allows you to specify the set of all PM counters supported by the Ethernet interface. For Incoming Flow direction, valid values: ALL (default), EINFg , EINFr. EINFg (Total Green Packets Received w/o Error) — The number of green frames (packets) received with error by the Virtual Ethernet Interface EINFr (Total Red Packets Received w/o Error) — The number of Red frames (packets) received without error by the Virtual Ethernet Interface. |
|
Time Period |
This field specifies whether the 15-minute and/or 1-day (24 hour) PM collection register is to be retrieved. Valid values: 15-MIN, 1-DAY, BOTH (default). |
|
Monitor Date |
The parameter specifies the starting date of the PM collection period for which PM data is to be reported. The date format is MM-DD (e.g. 12-03). The default value is current day. If the Time Period is 15-MIN, then the date and time specified by Monitor Date and Monitor Time is within the previous 8 hours of the current time. If Time Period is 1-DAY, then the date and time specified by Monitor Date and Monitor Time is within the previous 6 days of the current date. |
|
Monitor Time |
This parameter specifies the starting time of the PM collection period for which PM data is to be reported. It applies only if Time Period is 15- MIN or Time Period is ALL. The time format is HH-MM. The default value is current hour and beginning of the current 15-minute window. If the Time Period is 15-MIN, then the date and time specified by Monitor Date and Monitor Time is within the previous 8 hours of the current time. If Time Period of 1-DAY, then the date and time specified by Monitor Date and Monitor Time is within the previous 7 days of the current date. The minutes {00-14}, {15-29}, {30-44}, or {45- 59} specifies the first, second, third respective the fourth 15-minute period within the specified hour. |
|
Number of Previous 15-MIN Period |
The field does not apply if the Time Period is 1-Day. The number of historical register of 15-min. It specifies the number of previous 15-minute historical PM registers to retrieve in addition to that specified by Monitor Date and Monitor Time. The valid values are: ALL or an integer in the range of 1 - 32. The default value is 1. |
|
Number of Previous 1-Day Period |
The field does not apply if the Time Period is 15-MIN. The number of 1-day historical registers. It specifies the number of previous 1-day historical PM registers to retrieve in addition to that specified by Monitor Date and Monitor Time. The valid values are: ALL or an integer in the range of 1-6. The default value is 1. |
|
Display | ||
ETS Flow ID |
The ETS Flow ID. |
OpticsIMETSIn- FlowIndex |
Time Period |
Valid values: 1-DAY, 15-MIN. |
|
Date/Time |
Time stamped for the monitored data. |
|
Monitor Type |
This is the monitored PM parameter. See below. |
|
Suspect Interval Flag |
This is a flag indicating whether or not the PM history data is a Complete (False) or Partial (True) accumulation of PM data. This applies to the history PM bin data only. It does not apply to the current PM bin data and will either be removed (if the report contains current PM bin data only) or be blank (if the report contains both current and history PM bin data). Valid values: |
|
Elapsed Time |
This is the total time that the history PM data had been collected. This applies to the history PM bin data only. This does not apply to the current PM bin data and will either be removed (if the report contains current PM bin data only) or be blank (if the report contains both current and history PM bin data). |
|
Value |
The monitored count of the PM parameter. |