Use this procedure to provision the threshold values for a proactive DM session on a selected MEP. DM thresholds can be configured only when the associated proactive DM session is enabled.
Alarm thresholds are set for a proactive Delay Measurement session, for maximum or average measurement, Bidirectional (Round Trip) or One-way Delay, or Near-end or Far-end Delay Variation, 15 minute or 24 hour intervals.
The clear threshold must be lower than the cross threshold. The alarm is raised when a measurement equals or exceeds the cross threshold, which for maximum can occur anytime during a bin, and for average only at the end of a bin. The alarm is cleared when the measurement at the end of a bin is equal or less than the clear threshold. Because delay typically is above zero, take care when setting the clear threshold so that the TCA can clear under normal circumstances.
1 |
From the Navigation menu, select Service OA&M → Delay Measurement → Threshold Configuration to configure thresholds for the proactive delay measurement. Equivalent CLI command: ethoam dm-threshold Result: The Proactive DM Threshold Configuration window displays current settings. |
2 |
Enter the parameters as required. See Proactive DM Threshold parameters. Click Submit to execute the command. Click Delete to delete the threshold values from the selected Proactive DM session. End of steps |