Procedure 9-10.5: Configure Ethernet PM mode

- Overview

Use this procedure to configure the PM State for the Ethernet interface in the system.

Step
 
1

Log in to the VLNC42B.


2

From the Navigation menu, select TMPLS → Performance Monitoring → Ethernet PM Mode Configuration.

Result:

The Ethernet PM Mode Configuration screen displays.


3

From the Slot/Port drop-down box, select the Ethernet interface.


4

Provision the parameters as shown in Ethernet PM mode state parameters then click Submit.


End of steps

Ethernet PM mode state parameters

Parameter

Value

SNMP

Slot/Port

The Ethernet Interface AID. This is a drop-down list containing all Ethernet interfaces in the system. The default is the first Ethernet interface.

Direction

Valid values: Incoming, Outgoing.

Incoming: enhEth AggrCDRxTable or enhEthAggrHDRxTable

Outging: enhEthAggrCDTxTable or enhEthAggrHDTxTable

Time Period

This parameter identifies the accumulation time period for the PM Mode (1-day or 15- minute collection register).

Valid values

  • 15-MIN

  • 1-DAY

enhEthAggrCDRxGranularityPeriod

enhEthAggrCDTxGranularityPeriod

PM State

This parameter specifies whether the PM data collection is enabled or disabled for the selected Ethernet Port.

Valid values:

  • ON

    PM collection for all MONTYPE is enabled, PM counters are reset. Current data and History data are retrievable.

  • DISABLED

    PM collection for all MONTYPE is disabled. Current data and History data are not retrievable.

enhEthAggrCDRxRowStatus

enhEthAggrCDTxRowStatus