1 |
Log in to the VLNC42B. |
2 |
From the Navigation menu, select TMPLS → Performance Monitoring → Ethernet PM Mode Configuration. Result: The Ethernet PM Mode Configuration screen displays. |
3 |
From the Slot/Port drop-down box, select the Ethernet interface. |
4 |
Provision the parameters as shown in Ethernet PM mode state parameters then click Submit. End of steps |
Parameter |
Value |
SNMP |
---|---|---|
Slot/Port |
The Ethernet Interface AID. This is a drop-down list containing all Ethernet interfaces in the system. The default is the first Ethernet interface. |
|
Direction |
Valid values: Incoming, Outgoing. |
Incoming: enhEth AggrCDRxTable or enhEthAggrHDRxTable Outging: enhEthAggrCDTxTable or enhEthAggrHDTxTable |
Time Period |
This parameter identifies the accumulation time period for the PM Mode (1-day or 15- minute collection register). Valid values |
enhEthAggrCDRxGranularityPeriod enhEthAggrCDTxGranularityPeriod |
PM State |
This parameter specifies whether the PM data collection is enabled or disabled for the selected Ethernet Port. Valid values: |
enhEthAggrCDRxRowStatus enhEthAggrCDTxRowStatus |