How do I create a Wavence VPRN service?

Purpose

Use this procedure to create a Wavence VPRN service. The parameters that are available to you is dependant on the intent type that is associated with the service template you select, and may differ from those described in this procedure, which assumes the Nokia-provided Wavence VPRN template is being used.

Note: For Wavence VPRN services, validations from NFM-P are not propagated to NSP. For all the validation or error messages that correspond to service failures seen in NSP, the user should refer to the NFM-P logs.

Steps
 

Perform How do I create a service template?.


From the Service Management, Services view, click + CREATE.

The Select a service template to start form opens displaying a list of service templates.


Click on a Wavence VPRN service template from the list.

The Create Service form opens with the Template Name parameter populated.


Configure the parameters, as required:

Parameter

Description

Service Name

Specifies the name of the service. Must be unique from other services created using NSP.

Customer ID

Specifies the customer ID

Description

Describes the service

NE Service ID

Specifies the NE service ID


In the Site Details panel, click + ADD.

The Add Site form opens.


Configure the parameters, as required:

Parameter

Description

Site

Specifies the site to be used

VRF Name

Specifies the name of the VRF

Description

Describes the site

MTU

Specifies the MTU of the service

Auto Bind Tunnel

Resolution

Specifies the MBS of the queue


In the Interface Details panel, click + ADD.

The Add Interface form opens.


Configure the parameters, as required:

Parameter

Description

Interface Name

Specifies the name of the interface

Description

Describes the interface

IPv4/IPv6

Address

Specifies the primary IPv4/IPv6 address assigned to the interface

Prefix Length

Specifies the primary IPv4/IPv6 address prefix length

SAP

Port ID

Specifies the port to be used

Outer VLAN Tag

Specifies the outer VLAN tag

Description

Describes the SAP


Click ADD to add the interface. The Add Interface form closes.


10 

In the Static Route Details panel, click + ADD.

The Add Static Routes form opens.


11 

Configure the parameters, as required.

Parameter

Description

IP Prefix

Specifies the IP prefix for the static route

Prefix Length

Specifies the prefix length for the static route

Is Blackhole

Specifies whether the prefix is a blackhole route

Click ADD to add the static route. The Add Static Route form closes.


12 

Click ADD to add the site.

The Add Site form closes.


13 

In the SDP Details panel, click + ADD.

The Add SDP form opens.


14 

Configure the parameters, as required:

Parameter

Description

Source Device ID

Specifies the SDP source device identifier

Destination Device ID

Specifies the SDP destination device identifier

Ingress and Egress Label

Specifies the Ingress/Egress Label used by the Wavence node

SDP ID

Specifies the SDP identifier

VC ID

Specifies the SDP virtual circuit identifier

Click ADD to add the SDP binding. The Add SDP form closes.


15 

Perform one of the following:

  1. Select the Reserve Resources check box and click PLAN to create the service in a Planned state.

  2. Click SAVE to create the service in a Saved state.

  3. Click DEPLOY to create the service in a Deployed state.

See What is Life Cycle State? for more information.

End of steps