To create and run a CFM LM OAM diagnostic test from the STM

Steps
 

Choose Tools→Service Test Manager (STM) from the NFM-P main menu. The Service Test Manager form opens.


Click Create and choose Ethernet CFM→CFM LM Test. The CFM LM Test (Create) form opens.


Configure the required parameters.


Disable the NE Schedulable parameter.


Select a global MEG in the Test Object panel.


Select an originating MEP in the Test Object panel.

Note: MEPs can be added to services automatically or manually. If no MEPs are listed when you perform this step, see Ethernet CFM for information about how to configure a MEP that is required for this step.


To select the test destination using the target MAC Address:

  1. To select a MEP as the test destination, click Select MEP.

  2. To select a MIP as the test destination, click Select MIP.

    Note: MIP selection is not supported for OmniSwitch NEs.

  3. To select an unmanaged MEP as the test destination, click Select Unmanaged MEP.


Configure the required parameters in the MEP Transmit LM Information panel.


Save the changes and close the forms.


10 

To run the OAM diagnostic test and view the results, perform To run one or more OAM diagnostic tests from the STM and view the test results . See To interpret OAM diagnostic test results on the STM for information about how to interpret the test results.

End of steps