To create and run VCCV trace OAM diagnostic test from the STM

Steps

You can also perform this diagnostic test from a VLL service form, or from the service flat topology map. To create a VCCV trace OAM diagnostic test from a static PW to a dynamic PW segment, perform To create and run a VCCV trace OAM diagnostic from a static PW to a dynamic PW segment from the STM . To create a VCCV trace OAM diagnostic test from a dynamic PW to a static PW segment, perform To create and run a VCCV trace OAM diagnostic from a dynamic PW to a static PW segment from the STM .

 

Choose Tools→Service Test Manager (STM) from the NFM-P main menu. The Service Test Manager form opens.


Click Create and choose Service→VCCV Trace. The VCCV Trace (Create) form opens.


Configure the required parameters.


Set the Test Type parameter in the Test Object panel to Regular.


Select a spoke SDP binding in the First Spoke SDP Binding panel.


Configure the required parameters.


Set the Target FEC Type parameter to None.


Click on the Test Parameters tab and configure the required parameters.

The Probe History parameter is only configurable when the NE Schedulable parameter is enabled.

If you are configuring a VCCV trace test for a VLL with a switching site, you must set the Reply Type parameter to IP.


Click on the Results Configuration tab and configure the required parameters.


10 

Save the changes and close the forms.


11 

To run the OAM diagnostic test and view the results, perform To run one or more OAM diagnostic tests from the STM and view the test results . See To interpret OAM diagnostic test results on the STM for information about how to interpret the test results.

End of steps