To create and run a MPLS LSP trace OAM diagnostic test from the STM

Steps

The MPLS LSP Trace OAM diagnostic test is supported on both IPv4 and IPv6 source and destination addresses.

 

Choose Tools→Service Test Manager (STM) from the NFM-P main menu. The Service Test Manager form opens.


Click Create and choose MPLS→LSP Trace. The LSP Trace (Create) form opens.


Configure the required parameters. The available parameters change depending on the option specified for the Target Type parameter. Information about NFM-P parameters is available in the XML API Reference.


Click on the Test Parameters tab and configure the required parameters.

The Probe History parameter is only configurable when the NE Schedulable parameter is enabled.


Click on the Results Configuration tab and configure the required parameters.


As required, click on the NM Thresholds tab to configure threshold-crossing alarms.

Note: The NM Thresholds tab will only be displayed and configurable when the NE Schedulable parameter is not enabled. See To configure threshold-crossing alarms or NM threshold-crossing alarms for an OAM diagnostic test or STM test policy for more information.


Save the changes and close the forms.


To run the OAM diagnostic test and view the results, perform To run one or more OAM diagnostic tests from the STM and view the test results . See To interpret OAM diagnostic test results on the STM for information about how to interpret the test results.

End of steps