1 |
Create an FPE on the NE, with an SPD ID range configured and VXLAN termination enabled. See
To create an FPE
|
2 |
Create a VXLAN tunnel termination:
-
On the equipment tree, right-click on an NE and choose Properties. The Network Element (Edit) form opens.
-
Click on the Globals tab, then the Service sub-tab, then the VXLAN sub-tab, then the Tunnel Termination sub-tab.
-
Enter the tunnel termination IP address. The address must be a loopback interface address and a non-system IP address.
-
In the FPE panel, click Select and choose the FPE ID created in the previous step.
-
Click Apply and close the form.
|
3 |
Create a VPLS Site. See
To configure a VPLS site.
In the VXLAN Tunnel End Point panel, click Select and choose the VXLAN tunnel termination created in the previous step.
|
4 |
Create a system interface with an IPv4 address at the NE routing instance. See
To create an L3 network interface on a routing instance.
|
5 |
Configure the assisted replication IP address with the address configured in the previous step.
-
On the equipment tree, right-click on an NE and choose Properties. The Network Element (Edit) form opens.
-
Click on the Globals tab, then the Service sub-tab, then the General sub-tab.
-
Click Select and choose the interface created in the previous step, or enter the IP address of the interface.
|
6 |
Create a VXLAN identifier at the VPLS service:
-
Choose Manage→Service→Services from the NFM-P main menu. The Manage Services form opens.
-
Choose a VPLS service and click Properties. The VPLS Service (Edit) form opens.
-
Click on the BGP sub-tab, then the EVPN sub-tab.
-
Configure the parameters in the VXLAN panel.
To configure the Assisted Replication type parameter as Replicator, step
Step 5 must be completed.
End of steps |