To create and run a VCCV trace OAM diagnostic from a dynamic PW to a static PW segment from the STM

Steps

You can perform this test from a VPLS/MVPLS or VLL service form, or from the service flat topology map.

 

Choose Tools→Service Test Manager (STM) from the NFM-P main menu. The Service Test Manager form opens.


Click Create and choose Service→VCCV Trace. The VCCV Trace (Create) form opens.


Configure the required parameters.


Set the Test Type parameter in the Test Object panel to Regular.


Select the required spoke or mesh SDP binding in the First Spoke/Mesh SDP Binding panel.

Note: The selection of spoke bindings is applicable to both VPLS and VLL services; mesh bindings are only applicable to VPLS and MVPLS. However, when creating this test for MVPLS and VPLS, the concept of downstream spoke SDP bindings does not apply.


To configure this test for a VLL, select the required downstream spoke SDP binding in the Downstream SDP Binding panel.


Set the FEC Type parameter to Static.


Configure the required parameters in the Test Multi-Segment PW (Static) panel for the dynamic PW.


Click on the Test Parameters tab and configure the required parameters.

The Probe History parameter is only configurable when the NE Schedulable parameter is enabled.

If you are configuring a VCCV trace test for a VLL with a switching site, you must set the Reply Type parameter to IP.


10 

Click on the Results Configuration tab and configure the Required parameters.


11 

Save the changes and close the forms.


12 

To run the OAM diagnostic test and view the results, perform To run one or more OAM diagnostic tests from the STM and view the test results . See To interpret OAM diagnostic test results on the STM for information about how to interpret the test results.

End of steps