Radio Equipment Health Monitoring Summary report
Radio Equipment Health Monitoring Summary report overview
The Radio Equipment Health Monitoring Summary report shows the detailed information of the power voltage, current, and temperature values of the ports associated on the radio link. The operator can select multiple radio links for the selected temperature unit. The default unit for temperature is Celsius. The Radio Equipment Health Monitoring Summary report can be generated based on the radio links between the NEs of the respective ports or LAGs.
Use cases
Capacity planning—Use the report to examine the power voltage, current and temperature values based on the radio link between the NEs of the respective ports or LAGs.
Limitations
Minimum and maximum throughput aggregation cannot be compared with the minimum and maximum throughput values generated from raw granularity.
Prerequisites
Perform the following tasks using NSP Classic management to create a Radio Equipment Health Monitoring Details report:
-
enable the UBT/MPT Equipment Measurement (MPR) statistics by selecting the Product Name as ‘Wavence SM’
-
enable the Wavence MPT STATS Aggregator to view the report for granularities other than raw data
Report characteristics
The following table lists the principal report characteristics.
Note: The value of -99 means the data value is not available.
Table 15-23: Radio Equipment Health Monitoring Summary report characteristics
Characteristic |
Value | ||||
---|---|---|---|---|---|
Statistics type |
Performance statistics | ||||
NSP flow collector required |
No | ||||
NE types supported |
Wavence MSS-1, Wavence MSS-4, Wavence MSS-8, Wavence MSS-O, Wavence MSS-E, Wavence MSS-HE, Wavence MSS-XE, Wavence MSS-1c, Wavence SA, 9500 MPR-A Chassis 1, 9500 MPR-A Chassis 4, 9500 MPR-A Chassis 8, 9500 MPR-E Chassis 1, 9500 MPR-E Chassis 4, 9500 MPR-E Chassis 8, 9500 MSS-1c, 9500 MSS-O ANSI, 9500 MSS-O ETSI, 9500 SA Note: The 7705 SAR-H is not supported. | ||||
Report inputs |
Prompt |
Notes | |||
Start date End date |
Calendar date or relative date (for example, two days ago) and time | ||||
Granularity |
Aggregation types: | ||||
Links |
Select individual links or click Select All. | ||||
Temperature Unit |
Celsius or Fahrenheit | ||||
Temperature Threshold |
Specify the value using expression like >,<,=,<=,>=. | ||||
Power Threshold | |||||
Current Threshold | |||||
Voltage Threshold | |||||
Logo Resource ID |
The logo to add to the report. Enter the Resource ID of the logo image in the Images folder. The default is the Nokia logo. To create the report without a logo, leave the Logo Resource ID field blank. | ||||
Logo Position |
Choose Left, Middle, or Right. The logo appears on the left on the first page of the report if you choose Left or Middle. | ||||
Show report output on one page |
Select the check box to enable pagination. Note: Using the Show report output on one page option when creating reports as drill-downs may impact report rendering time. Nokia recommends disabling the Show report output on one page option when creating reports. | ||||
Apply |
Applies all the parameters and prepares the report based on the parameters entered. | ||||
Reset |
Resets all the parameters to default value. | ||||
Drill-down support |
Yes—Open the Radio Equipment Health Monitoring Details Report for the select NE. |
Example
The following figures show a report example.