Radio Equipment Health Monitoring Summary report

Radio Equipment Health Monitoring Summary report overview

The Radio Equipment Health Monitoring Summary report shows the detailed information of the power voltage, current, and temperature values of the ports associated on the radio link. The operator can select multiple radio links for the selected temperature unit. The default unit for temperature is Celsius. The Radio Equipment Health Monitoring Summary report can be generated based on the radio links between the NEs of the respective ports or LAGs.

Use cases

Capacity planning—Use the report to examine the power voltage, current and temperature values based on the radio link between the NEs of the respective ports or LAGs.

Limitations

Minimum and maximum throughput aggregation cannot be compared with the minimum and maximum throughput values generated from raw granularity.

Prerequisites

Perform the following tasks using NSP Classic management to create a Radio Equipment Health Monitoring Details report:

Report characteristics

The following table lists the principal report characteristics.

Note: The value of -99 means the data value is not available.

Table 15-23: Radio Equipment Health Monitoring Summary report characteristics

Characteristic

Value

Statistics type

Performance statistics

NSP flow collector required

No

NE types supported

Wavence MSS-1, Wavence MSS-4, Wavence MSS-8, Wavence MSS-O, Wavence MSS-E, Wavence MSS-HE, Wavence MSS-XE, Wavence MSS-1c, Wavence SA, 9500 MPR-A Chassis 1, 9500 MPR-A Chassis 4, 9500 MPR-A Chassis 8, 9500 MPR-E Chassis 1, 9500 MPR-E Chassis 4, 9500 MPR-E Chassis 8, 9500 MSS-1c, 9500 MSS-O ANSI, 9500 MSS-O ETSI, 9500 SA

Note: The 7705 SAR-H is not supported.

Report inputs

Prompt

Notes

Start date

End date

Calendar date or relative date (for example, two days ago) and time

Granularity

Aggregation types:

  • None (raw data)

  • Hourly

  • Daily

  • Monthly

Links

Select individual links or click Select All.

Temperature Unit

Celsius or Fahrenheit

Temperature Threshold

Specify the value using expression like >,<,=,<=,>=.

Power Threshold

Current Threshold

Voltage Threshold

Logo Resource ID

The logo to add to the report. Enter the Resource ID of the logo image in the Images folder. The default is the Nokia logo. To create the report without a logo, leave the Logo Resource ID field blank.

Logo Position

Choose Left, Middle, or Right. The logo appears on the left on the first page of the report if you choose Left or Middle.

Show report output on one page

Select the check box to enable pagination.

Note: Using the Show report output on one page option when creating reports as drill-downs may impact report rendering time. Nokia recommends disabling the Show report output on one page option when creating reports.

Apply

Applies all the parameters and prepares the report based on the parameters entered.

Reset

Resets all the parameters to default value.

Drill-down support

Yes—Open the Radio Equipment Health Monitoring Details Report for the select NE.

Example

The following figures show a report example.

Figure 15-28: Radio Equipment Health Monitoring Summary report
Radio Equipment Health Monitoring Summary report
Figure 15-29: Radio Equipment Health Monitoring Summary report, continued
Radio Equipment Health Monitoring Summary report, continued