To update the software activation status for Wavence SA nodes
Purpose
When software activation is performed via an MCT (microwave craft terminal) on a managed Wavence SA node, NFM-P does not indicate whether the software activation was successful. Perform this procedure to update the software activation status by applying a forced activation to the node. This procedure causes the Wavence SA node to reboot.
CAUTION Service Disruption |
Perform this procedure only in a maintenance window:
When you reboot a Wavence that is in service, it is service-affecting. Ensure that the reboot activity occurs during a maintenance window.
Steps
1 |
In the navigation tree Equipment view, right-click on a Wavence SA shelf and choose Properties. The Shelf (Edit) form opens. |
2 |
Click on the Software Bank Details tab, select the Standby bank, and click Properties. The MPR Software Package (Edit) form opens. |
3 |
Set the Activation parameter to Forced Activation and click Apply. The node reboots. |
4 |
Close the form. End of steps |