To configure Tx mute on radio ports

Steps
 

On the equipment tree, expand Network→Wavence→Card Slot.


Right-click on the radio port object and choose Properties. The Physical Port (Edit) form opens.


Click on the Radio tab and perform one of the following:

  1. Set the Manual Local Tx Mute parameter on the Tx Mute panel to On and the transmitter is muted indefinitely.

  2. Perform the following to provide a duration during which the transmitter is muted:

    1. Set the Manual Local Tx Mute parameter to Timed.

    2. Configure the Manual Local Timeout (minutes) parameter. The maximum duration is 2880 min (2 days).

      Note: You cannot set the Manual Local Timeout (minutes) to 0.

Note: It is not possible to change the Tx Mute parameter values from Timed to On or On to Timed. In both cases, change the Tx Mute parameter values from Timed to Off, then to On.


Save the changes and close the form.

End of steps