1 |
In the Network Map and Health, Current Alarms view, click the More button and select Settings. The Alarm Settings form opens.
|
2 |
Click Current Alarms on the left-hand panel.
|
3 |
Enable the Aging Settings option and specify the number of days after which alarms are deleted.
|
4 |
Under Overflow Settings, specify the percentage of the maximum alarm count at which an alarm overflow warning is issued.
Note: The maximum count for alarms from sources other than the NFM-P is 250 000 if the WS-NOC and NSP are integrated, or 300 000 if the WS-NOC is deployed as an independent system.
|
5 |
Specify an overflow action. If you choose Halt, all new alarms are dropped. If you choose Wrap, alarms are purged from the database, based on the following settings:
|
6 |
Save your changes.
End of steps |