CHASSIS

CpmIcPortSFFStatusDDMCorrupt

Table 1. CpmIcPortSFFStatusDDMCorrupt properties

Property name

Value

Application name

CHASSIS

Event ID

4012

Event name

CpmIcPortSFFStatusDDMCorrupt

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.7

Default severity

minor

Message format string

CPM interconnect port SFF DDM checksums do not match

Cause

The tmnxCpmIcPortSFFStatusFailure notification is generated when the value of tmnxCpmIcPortSFFStatus results in a value other than 'not-equipped (0)', or 'operational (1)'.

Effect

The SFF device is not operational and the associated CPM interconnect port cannot be used. The SFF and port will not recover without operator intervention.

Recovery

Remove and reinsert the SFF device. If the problem persists then replace the SFF device.

CpmIcPortSFFStatusFailure

Table 2. CpmIcPortSFFStatusFailure properties

Property name

Value

Application name

CHASSIS

Event ID

4011

Event name

CpmIcPortSFFStatusFailure

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.7

Default severity

minor

Message format string

CPM interconnect port SFF checksums do not match

Cause

The tmnxCpmIcPortSFFStatusFailure notification is generated when the value of tmnxCpmIcPortSFFStatus results in a value other than 'not-equipped (0)', or 'operational (1)'.

Effect

The SFF device is not operational and the associated CPM interconnect port cannot be used. The SFF and port will not recover without operator intervention.

Recovery

Remove and reinsert the SFF device. If the problem persists then replace the SFF device.

CpmIcPortSFFStatusReadError

Table 3. CpmIcPortSFFStatusReadError properties

Property name

Value

Application name

CHASSIS

Event ID

4013

Event name

CpmIcPortSFFStatusReadError

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.7

Default severity

minor

Message format string

CPM interconnect port SFF read failure

Cause

The tmnxCpmIcPortSFFStatusFailure notification is generated when the value of tmnxCpmIcPortSFFStatus results in a value other than 'not-equipped (0)', or 'operational (1)'.

Effect

The SFF device is not operational and the associated CPM interconnect port cannot be used. The SFF and port will not recover without operator intervention.

Recovery

Remove and reinsert the SFF device. If the problem persists then replace the SFF device.

CpmIcPortSFFStatusUnsupported

Table 4. CpmIcPortSFFStatusUnsupported properties

Property name

Value

Application name

CHASSIS

Event ID

4014

Event name

CpmIcPortSFFStatusUnsupported

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.7

Default severity

minor

Message format string

CPM interconnect port SFF unsupported type

Cause

The tmnxCpmIcPortSFFStatusFailure notification is generated when the value of tmnxCpmIcPortSFFStatus results in a value other than 'not-equipped (0)', or 'operational (1)'.

Effect

The SFF device is not operational and the associated CPM interconnect port cannot be used. The SFF and port will not recover without operator intervention.

Recovery

Remove and reinsert the SFF device. If the problem persists then replace the SFF device.

SfmIcPortSFFStatusDDMCorrupt

Table 5. SfmIcPortSFFStatusDDMCorrupt properties

Property name

Value

Application name

CHASSIS

Event ID

4022

Event name

SfmIcPortSFFStatusDDMCorrupt

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.5

Default severity

minor

Message format string

SFM interconnect port SFF DDM checksums do not match

Cause

The tmnxSfmIcPortSFFStatusFailure notification is generated when the value of tmnxSfmIcPortSFFStatus results in a value other than 'not-equipped (0)', or 'operational (1)'.

Effect

The SFF device is not operational and the associated SFM interconnect port cannot be used. The SFF and port will not recover without operator intervention.

Recovery

Remove and reinsert the SFF device. If the problem persists then replace the SFF device.

SfmIcPortSFFStatusFailure

Table 6. SfmIcPortSFFStatusFailure properties

Property name

Value

Application name

CHASSIS

Event ID

4021

Event name

SfmIcPortSFFStatusFailure

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.5

Default severity

minor

Message format string

SFM interconnect port SFF checksums do not match

Cause

The tmnxSfmIcPortSFFStatusFailure notification is generated when the value of tmnxSfmIcPortSFFStatus results in a value other than 'not-equipped (0)', or 'operational (1)'.

Effect

The SFF device is not operational and the associated SFM interconnect port cannot be used. The SFF and port will not recover without operator intervention.

Recovery

Remove and reinsert the SFF device. If the problem persists then replace the SFF device.

SfmIcPortSFFStatusReadError

Table 7. SfmIcPortSFFStatusReadError properties

Property name

Value

Application name

CHASSIS

Event ID

4023

Event name

SfmIcPortSFFStatusReadError

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.5

Default severity

minor

Message format string

SFM interconnect port SFF read failure

Cause

The tmnxSfmIcPortSFFStatusFailure notification is generated when the value of tmnxSfmIcPortSFFStatus results in a value other than 'not-equipped (0)', or 'operational (1)'.

Effect

The SFF device is not operational and the associated SFM interconnect port cannot be used. The SFF and port will not recover without operator intervention.

Recovery

Remove and reinsert the SFF device. If the problem persists then replace the SFF device.

SfmIcPortSFFStatusUnsupported

Table 8. SfmIcPortSFFStatusUnsupported properties

Property name

Value

Application name

CHASSIS

Event ID

4024

Event name

SfmIcPortSFFStatusUnsupported

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.5

Default severity

minor

Message format string

SFM interconnect port SFF unsupported type

Cause

The tmnxSfmIcPortSFFStatusFailure notification is generated when the value of tmnxSfmIcPortSFFStatus results in a value other than 'not-equipped (0)', or 'operational (1)'.

Effect

The SFF device is not operational and the associated SFM interconnect port cannot be used. The SFF and port will not recover without operator intervention.

Recovery

Remove and reinsert the SFF device. If the problem persists then replace the SFF device.

tChassisAirflowDirMismatch

Table 9. tChassisAirflowDirMismatch properties

Property name

Value

Application name

CHASSIS

Event ID

2233

Event name

tChassisAirflowDirMismatch

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.244

Default severity

critical

Message format string

$tmnxHwClass$ $tmnxChassisNotifyHwIndex$: airflow direction mismatch

Cause

The tChassisAirflowDirMismatch notification is generated when airflow direction is not identical for all chassis fans and power-supply fans equipped by the physical chassis.

Effect

Mismatched airflow direction among fans may cause increased temperature, intermittent errors, and could damage components.

Recovery

The operator must identify a single preferred airflow direction, remove any chassis fans and power-supply fans which do not match it, and replace them with equipment having fans of the preferred airflow direction.

tChassisAirflowDirMismatchClr

Table 10. tChassisAirflowDirMismatchClr properties

Property name

Value

Application name

CHASSIS

Event ID

2234

Event name

tChassisAirflowDirMismatchClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.245

Default severity

critical

Message format string

$tmnxHwClass$ $tmnxChassisNotifyHwIndex$: airflow direction mismatch cleared

Cause

The tChassisAirflowDirMismatchClr notification is generated to indicate that all chassis fans and power-supply fans with mismatched airflow directions have been replaced, and all chassis-fans and power-supply fans share the same direction.

Effect

N/A

Recovery

N/A

tChassisPowerSupplyMismatch

Table 11. tChassisPowerSupplyMismatch properties

Property name

Value

Application name

CHASSIS

Event ID

2235

Event name

tChassisPowerSupplyMismatch

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.246

Default severity

critical

Message format string

$tmnxHwClass$ $tmnxChassisNotifyHwIndex$: power-supply type mismatch

Cause

The tChassisPowerSupplyMismatch notification is generated when power-supply elements equipped to the physical chassis are not all of the same type.

Effect

There is an increased risk of power-supply failure. Intermittent error or damage to components may also result.

Recovery

The operator must identify a single preferred or required power-supply type, remove any power-supply elements of other types, and replace them with equipment of the preferred power-supply type.

tChassisPowerSupplyMismatchClr

Table 12. tChassisPowerSupplyMismatchClr properties

Property name

Value

Application name

CHASSIS

Event ID

2236

Event name

tChassisPowerSupplyMismatchClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.247

Default severity

critical

Message format string

$tmnxHwClass$ $tmnxChassisNotifyHwIndex$: power-supply type mismatch cleared

Cause

The tChassisPowerSupplyMismatchClr notification is generated to indicate that all power-supply elements of mismatched types have been replaced, and all power-supply elements now share the same type.

Effect

N/A

Recovery

N/A

tChassisPowerSupplyUnsup

Table 13. tChassisPowerSupplyUnsup properties

Property name

Value

Application name

CHASSIS

Event ID

2237

Event name

tChassisPowerSupplyUnsup

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.248

Default severity

critical

Message format string

$tmnxChassisNotifyHwIndex$: power-supply not supported

Cause

The tChassisPowerSupplyUnsup notification is generated when power-supply elements equipped to the physical chassis are not of a supported type.

Effect

There is an increased risk of power-supply failure. Intermittent error or damage to components may also result.

Recovery

The operator must identify any equipped power supply elements of unsupported type, remove them, and replace them with equipment of a supported power-supply type

tIPsecEsaVmMemHighWatermark

Table 14. tIPsecEsaVmMemHighWatermark properties

Property name

Value

Application name

CHASSIS

Event ID

2220

Event name

tIPsecEsaVmMemHighWatermark

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.231

Default severity

minor

Message format string

The memory usage ratio for ESA-VM $tmnxEsaNotifyId$/$tmnxEsaVmNotifyId$ has almost reached the maximum value.

Cause

A tIPsecEsaVmMemHighWatermark notification is generated when the ESA VM memory usage ratio has almost reached the maximum value.

Effect

The system may stop accepting new IKE states shortly.

Recovery

Use fewer SAs for each IKE tunnel.

tIPsecEsaVmMemLowWatermark

Table 15. tIPsecEsaVmMemLowWatermark properties

Property name

Value

Application name

CHASSIS

Event ID

2219

Event name

tIPsecEsaVmMemLowWatermark

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.230

Default severity

minor

Message format string

The memory usage ratio for ESA-VM $tmnxEsaNotifyId$/$tmnxEsaVmNotifyId$ has dropped back to the normal level.

Cause

A tIPsecEsaVmMemLowWatermark notification is generated when the ESA VM memory usage ratio has dropped back to the normal level.

Effect

The system accepts new IKE states.

Recovery

There is no recovery required for this notification.

tIPsecIsaMemHighWatermark

Table 16. tIPsecIsaMemHighWatermark properties

Property name

Value

Application name

CHASSIS

Event ID

2151

Event name

tIPsecIsaMemHighWatermark

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.138

Default severity

minor

Message format string

The memory usage ratio for ISA $tmnxCardSlotNum$/$tmnxMDASlotNum$ has almost reached the maximum value.

Cause

A tIPsecIsaMemHighWatermark notification is generated when the ISA card memory usage ratio has almost reached the maximum value.

Effect

The system may stop accepting new IKE states shortly.

Recovery

Use fewer SAs for each IKE tunnel.

tIPsecIsaMemLowWatermark

Table 17. tIPsecIsaMemLowWatermark properties

Property name

Value

Application name

CHASSIS

Event ID

2150

Event name

tIPsecIsaMemLowWatermark

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.137

Default severity

minor

Message format string

The memory usage ratio for ISA $tmnxCardSlotNum$/$tmnxMDASlotNum$ has dropped back to the normal level.

Cause

A tIPsecIsaMemLowWatermark notification is generated when the ISA card memory usage ratio has dropped back to the normal level.

Effect

The system accepts new IKE states.

Recovery

There is no recovery required for this notification.

tIPsecIsaMemMax

Table 18. tIPsecIsaMemMax properties

Property name

Value

Application name

CHASSIS

Event ID

2152

Event name

tIPsecIsaMemMax

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.139

Default severity

minor

Message format string

The memory usage for ISA $tmnxCardSlotNum$/$tmnxMDASlotNum$ has reached the maximum value.

Cause

A tIPsecIsaMemMax notification is generated when the ISA card memory usage ratio has reached the maximum value.

Effect

The system stops accepting new IKE states.

Recovery

Use fewer SAs for each IKE tunnel.

tmnxAlarmInputVoltageFailure

Table 19. tmnxAlarmInputVoltageFailure properties

Property name

Value

Application name

CHASSIS

Event ID

3014

Event name

tmnxAlarmInputVoltageFailure

SNMP notification prefix and OID

TIMETRA-SAS-ALARM-INPUT-MIB.tmnxSASChassisNotification.10

Default severity

major

Message format string

Class $tmnxHwClass$ : alarm input voltage failure

Cause

A tmnxAlarmInputVoltageFailure notification is sent when the internal power supply for alarm inputs fails. The value of tmnxSasAlarmInputPowerStatus indicates whether the power to external alarm inputs is on or off.

Effect

If the alarm inputs use the internal power supply, then a failure in the power supply will cause state change event alarms to not be raised.

Recovery

Check the internal power source for alarm inputs and rectify the problem.

tmnxBluetoothModuleConnectionChg

Table 20. tmnxBluetoothModuleConnectionChg properties

Property name

Value

Application name

CHASSIS

Event ID

2187

Event name

tmnxBluetoothModuleConnectionChg

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.178

Default severity

minor

Message format string

Bluetooth Module $tmnxChassisNotifyCpmCardSlotNum$ got $tmnxBluetoothModuleConnected$ to $tmnxBluetoothModuleConnectedMac$.

Cause

The tmnxBluetoothModuleConnectionChg notification is generated when a remote Bluetooth device connects with or disconnects from the indicated Bluetooth module.

Effect

A Bluetooth device has connected with or disconnected from a Bluetooth module.

Recovery

No recovery required.

tmnxCardResMacFdbHighUsgClr

Table 21. tmnxCardResMacFdbHighUsgClr properties

Property name

Value

Application name

CHASSIS

Event ID

5164

Event name

tmnxCardResMacFdbHighUsgClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.149

Default severity

minor

Message format string

The FDB table usage for card $tmnxMacScaleCardSlotNum$ is below 90% of the card limit

Cause

The tmnxCardResMacFdbHighUsgClr notification is generated when the FDB table size drops below 90% of the card limit.

Effect

The FDB table size for the card drops below 90% of the card limit.

Recovery

None needed.

tmnxCardResMacFdbHighUsgSet

Table 22. tmnxCardResMacFdbHighUsgSet properties

Property name

Value

Application name

CHASSIS

Event ID

5163

Event name

tmnxCardResMacFdbHighUsgSet

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.148

Default severity

minor

Message format string

The FDB table usage for card $tmnxMacScaleCardSlotNum$ is above 95% of the card limit

Cause

The tmnxCardResMacFdbHighUsgSet notification is generated when the FDB table size exceeds 95% of the card limit.

Effect

The FDB table size for the card exceeds 95% of the card limit.

Recovery

None needed.

tmnxChassisHiBwMcastAlarm

Table 23. tmnxChassisHiBwMcastAlarm properties

Property name

Value

Application name

CHASSIS

Event ID

2052

Event name

tmnxChassisHiBwMcastAlarm

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.43

Default severity

minor

Message format string

Class $tmnxHwClass$ : Plane shared by multiple multicast high bandwidth taps

Cause

The tmnxChassisHiBwMcastAlarm notification is generated when a plane is shared by more than one high bandwidth multicast tap.

Effect

N/A

Recovery

N/A

tmnxChassisNotificationClear

Table 24. tmnxChassisNotificationClear properties

Property name

Value

Application name

CHASSIS

Event ID

2016

Event name

tmnxChassisNotificationClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.25

Default severity

major

Message format string

Clear $tmnxHwClass$ $tmnxHwIndex$ $tmnxChassisNotifyOID$

Cause

A trap indicating the clear of a chassis notification identified by tmnxChassisNotifyOID.

Effect

N/A

Recovery

N/A

tmnxChassisUpgradeComplete

Table 25. tmnxChassisUpgradeComplete properties

Property name

Value

Application name

CHASSIS

Event ID

2034

Event name

tmnxChassisUpgradeComplete

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.42

Default severity

major

Message format string

Class $tmnxHwClass$ : software upgrade complete

Cause

The tmnxChassisUpgradeComplete notification is generated to indicate that all the IOMs are running matching software versions in reference to the active CPM software version changed as part of the upgrade process.

Effect

N/A

Recovery

N/A

tmnxChassisUpgradeInProgress

Table 26. tmnxChassisUpgradeInProgress properties

Property name

Value

Application name

CHASSIS

Event ID

2033

Event name

tmnxChassisUpgradeInProgress

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.41

Default severity

major

Message format string

Class $tmnxHwClass$ : software upgrade in progress

Cause

The tmnxChassisUpgradeInProgress notification is generated only after a CPM switchover occurs and the new active CPM is running new software, while the IOMs or XCMs are still running old software. This is the start of the upgrade process. The tmnxChassisUpgradeInProgress notification will continue to be generated every 30 minutes while at least one IOM is still running older software.

Effect

A software mismatch between the CPM and IOM or XCM is generally fine for a short duration (during an upgrade) but may not allow for correct long-term operation.

Recovery

Complete the upgrade of all IOMs or XCMs.

tmnxCpmALocalIcPortAvail

Table 27. tmnxCpmALocalIcPortAvail properties

Property name

Value

Application name

CHASSIS

Event ID

4009

Event name

tmnxCpmALocalIcPortAvail

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.6

Default severity

major

Message format string

CPM $tmnxChassisNotifyCpmCardSlotNum$ can reach the chassis using its local CPM interconnect ports

Cause

The tmnxCpmLocalIcPortAvail notification is generated when the CPM re-establishes communication with the other chassis using its local CPM interconnect ports.

Effect

A new control communications path is now available between the CPM and the other chassis.

Recovery

N/A

tmnxCpmANoLocalIcPort

Table 28. tmnxCpmANoLocalIcPort properties

Property name

Value

Application name

CHASSIS

Event ID

4007

Event name

tmnxCpmANoLocalIcPort

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.5

Default severity

major

Message format string

CPM $tmnxChassisNotifyCpmCardSlotNum$ can not reach the chassis using its local CPM interconnect ports

Cause

The tmnxCpmNoLocalIcPort alarm is generated when the CPM cannot reach the other chassis using its local CPM interconnect ports.

Effect

Another control communications path may still be available between the CPM and the other chassis via the mate CPM in the same chassis. If that alternative path is not available then complete disruption of control communications to the other chassis will occur and the tmnxInterChassisCommsDown alarm is raised. A tmnxCpmNoLocalIcPort alarm on the active CPM indicates that a further failure of the local CPM interconnect ports on the standby CPM will cause complete disruption of control communications to the other chassis and the tmnxInterChassisCommsDown alarm is raised. A tmnxCpmNoLocalIcPort alarm on the standby CPM indicates that a CPM switchover may cause temporary disruption of control communications to the other chassis while the rebooting CPM comes back into service.

Recovery

Ensure that all CPM interconnect ports in the system are properly cabled together with working cables.

tmnxCpmBLocalIcPortAvail

Table 29. tmnxCpmBLocalIcPortAvail properties

Property name

Value

Application name

CHASSIS

Event ID

4010

Event name

tmnxCpmBLocalIcPortAvail

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.6

Default severity

major

Message format string

CPM $tmnxChassisNotifyCpmCardSlotNum$ can reach the chassis using its local CPM interconnect ports

Cause

The tmnxCpmLocalIcPortAvail notification is generated when the CPM re-establishes communication with the other chassis using its local CPM interconnect ports.

Effect

A new control communications path is now available between the CPM and the other chassis.

Recovery

N/A

tmnxCpmBNoLocalIcPort

Table 30. tmnxCpmBNoLocalIcPort properties

Property name

Value

Application name

CHASSIS

Event ID

4008

Event name

tmnxCpmBNoLocalIcPort

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.5

Default severity

major

Message format string

CPM $tmnxChassisNotifyCpmCardSlotNum$ can not reach the chassis using its local CPM interconnect ports

Cause

The tmnxCpmNoLocalIcPort alarm is generated when the CPM cannot reach the other chassis using its local CPM interconnect ports.

Effect

Another control communications path may still be available between the CPM and the other chassis via the mate CPM in the same chassis. If that alternative path is not available then complete disruption of control communications to the other chassis will occur and the tmnxInterChassisCommsDown alarm is raised. A tmnxCpmNoLocalIcPort alarm on the active CPM indicates that a further failure of the local CPM interconnect ports on the standby CPM will cause complete disruption of control communications to the other chassis and the tmnxInterChassisCommsDown alarm is raised. A tmnxCpmNoLocalIcPort alarm on the standby CPM indicates that a CPM switchover may cause temporary disruption of control communications to the other chassis while the rebooting CPM comes back into service.

Recovery

Ensure that all CPM interconnect ports in the system are properly cabled together with working cables.

tmnxCpmCardSyncFileNotPresent

Table 31. tmnxCpmCardSyncFileNotPresent properties

Property name

Value

Application name

CHASSIS

Event ID

2057

Event name

tmnxCpmCardSyncFileNotPresent

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.45

Default severity

minor

Message format string

Class $tmnxHwClass$ : Optional file $tmnxChassisNotifyCardSyncFile$ is not present during sync operation

Cause

The tmnxCpmCardSyncFileNotPresent notification is generated when the redundancy file synchronization failed to locate an optional file.

Effect

N/A

Recovery

N/A

tmnxCpmIcPortDDMClear

Table 32. tmnxCpmIcPortDDMClear properties

Property name

Value

Application name

CHASSIS

Event ID

4016

Event name

tmnxCpmIcPortDDMClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.9

Default severity

minor

Message format string

CPM interconnect port SFF DDM $tmnxDDMLaneIdOrModule$ ($tmnxDDMFailedObject$) cleared

Cause

The tmnxCpmIcPortDDMFailure notification is generated when an SFF in a CPM interconnect port that supports Digital Diagnostic Monitoring (DDM) clears a failed state.

Effect

N/A

Recovery

N/A

tmnxCpmIcPortDDMFailure

Table 33. tmnxCpmIcPortDDMFailure properties

Property name

Value

Application name

CHASSIS

Event ID

4015

Event name

tmnxCpmIcPortDDMFailure

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.8

Default severity

minor

Message format string

CPM interconnect port SFF DDM $tmnxDDMLaneIdOrModule$ ($tmnxDDMFailedObject$) raised

Cause

The tmnxCpmIcPortDDMFailure notification is generated when an SFF in a CPM interconnect port that supports Digital Diagnostic Monitoring (DDM) enters a failed state.

Effect

N/A

Recovery

N/A

tmnxCpmIcPortDown

Table 34. tmnxCpmIcPortDown properties

Property name

Value

Application name

CHASSIS

Event ID

4003

Event name

tmnxCpmIcPortDown

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.1

Default severity

minor

Message format string

CPM interconnect port is not operational. Error code = $tmnxCpmIcPortOperState$

Cause

The tmnxCpmIcPortDown alarm is generated when the CPM interconnect port is not operational. The reason may be a cable connected incorrectly, a disconnected cable, a faulty cable, or a misbehaving CPM interconnect port or card.

Effect

At least one of the control plane paths used for inter-chassis CPM communication is not operational. Other paths may be available.

Recovery

A manual verification and testing of each CPM interconnect port is required to ensure fully functional operation. Physical replacement of cabling may be required.

tmnxCpmIcPortSFFInserted

Table 35. tmnxCpmIcPortSFFInserted properties

Property name

Value

Application name

CHASSIS

Event ID

4005

Event name

tmnxCpmIcPortSFFInserted

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.3

Default severity

minor

Message format string

CPM interconnect port SFF inserted

Cause

The tmnxCpmIcPortSFFInserted notification is generated when the small form factor (SFF) pluggable optical module (eg. QSFP) is inserted into a CPM interconnect port.

Effect

This event is for notification only.

Recovery

N/A

tmnxCpmIcPortSFFRemoved

Table 36. tmnxCpmIcPortSFFRemoved properties

Property name

Value

Application name

CHASSIS

Event ID

4006

Event name

tmnxCpmIcPortSFFRemoved

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.4

Default severity

minor

Message format string

CPM interconnect port SFF removed

Cause

The tmnxCpmIcPortSFFRemoved notification is generated when the SFF (eg. QSFP) is removed from the CPM interconnect port. Removing an SFF causes both this trap, and also a tmnxCpmIcPortDown event.

Effect

Removing the SFF will cause the CPM interconnect port to go down. This port will no longer be able to be used as part of the control plane between chassis but other paths may be available.

Recovery

Insert a working SFF into the port.

tmnxCpmIcPortUp

Table 37. tmnxCpmIcPortUp properties

Property name

Value

Application name

CHASSIS

Event ID

4004

Event name

tmnxCpmIcPortUp

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxCpmIcPortNotifications.2

Default severity

minor

Message format string

CPM interconnect port is operational

Cause

The tmnxCpmIcPortUp notification is generated when the CPM interconnect port is operational again.

Effect

A control plane communication path between CPM cards in the different chassis have been established.

Recovery

N/A

tmnxCpmMemSizeMismatch

Table 38. tmnxCpmMemSizeMismatch properties

Property name

Value

Application name

CHASSIS

Event ID

2153

Event name

tmnxCpmMemSizeMismatch

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.140

Default severity

major

Message format string

The standby CPM $tmnxChassisNotifyCpmCardSlotNum$ has a different memory size than the active $tmnxChassisNotifyHwIndex$

Cause

A tmnxCpmMemSizeMismatch notification is generated when the RAM memory size of the standby CPM (i.e., tmnxChassisNotifyCpmCardSlotNum) is different than the active CPM (i.e., tmnxChassisNotifyHwIndex).

Effect

There is an increased risk of the memory overflow on the standby CPM during the CPM switchover.

Recovery

Use CPMs with the same memory size.

tmnxCpmMemSizeMismatchClear

Table 39. tmnxCpmMemSizeMismatchClear properties

Property name

Value

Application name

CHASSIS

Event ID

2154

Event name

tmnxCpmMemSizeMismatchClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.141

Default severity

cleared

Message format string

The standby CPM $tmnxChassisNotifyCpmCardSlotNum$ has the same memory size as the active $tmnxChassisNotifyHwIndex$

Cause

A tmnxCpmMemSizeMismatchClear notification is generated when the RAM memory sizes of the standby (i.e., tmnxChassisNotifyCpmCardSlotNum) and active (i.e., tmnxChassisNotifyHwIndex) CPMs become matched.

Effect

The tmnxCpmMemSizeMismatch notification is cleared.

Recovery

There is no recovery required for this notification.

tmnxDcpCardFpEventOvrflw

Table 40. tmnxDcpCardFpEventOvrflw properties

Property name

Value

Application name

CHASSIS

Event ID

2084

Event name

tmnxDcpCardFpEventOvrflw

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.72

Default severity

minor

Message format string

TODO

Cause

The tmnxDcpCardFpEventOvrflw notification is generated when a flood of distributed CPU FP protection events occur on a particular card and some of the events are lost due to event throttling mechanism.

Effect

Some FP notifications configured on the card may not be received.

Recovery

Notifications will resume once the event throttling ends.

tmnxDcpCardFpEventOvrflwClr

Table 41. tmnxDcpCardFpEventOvrflwClr properties

Property name

Value

Application name

CHASSIS

Event ID

2089

Event name

tmnxDcpCardFpEventOvrflwClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.77

Default severity

minor

Message format string

TODO

Cause

The tmnxDcpCardFpEventOvrflwClr notification is generated when the event throttling has ended for distributed CPU protection FP events on a particular card.

Effect

Notifications are received again since the event throttling has ended.

Recovery

There is no recovery for this notification.

tmnxDcpCardSapEventOvrflw

Table 42. tmnxDcpCardSapEventOvrflw properties

Property name

Value

Application name

CHASSIS

Event ID

2085

Event name

tmnxDcpCardSapEventOvrflw

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.73

Default severity

minor

Message format string

TODO

Cause

The tmnxDcpCardSapEventOvrflw notification is generated when a flood of distributed CPU protection SAP events occur on a particular card and some of the events are lost due to event throttling mechanism.

Effect

Some SAP notifications configured on the card may not be received.

Recovery

Notifications will resume once the event throttling ends.

tmnxDcpCardSapEventOvrflwClr

Table 43. tmnxDcpCardSapEventOvrflwClr properties

Property name

Value

Application name

CHASSIS

Event ID

2090

Event name

tmnxDcpCardSapEventOvrflwClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.78

Default severity

minor

Message format string

TODO

Cause

The tmnxDcpCardSapEventOvrflwClr notification is generated when the event throttling has ended for distributed CPU protection SAP events on a particular card.

Effect

Notifications are received again since the event throttling has ended.

Recovery

There is no recovery for this notification.

tmnxDcpCardVrtrIfEventOvrflw

Table 44. tmnxDcpCardVrtrIfEventOvrflw properties

Property name

Value

Application name

CHASSIS

Event ID

2086

Event name

tmnxDcpCardVrtrIfEventOvrflw

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.74

Default severity

minor

Message format string

TODO

Cause

The tmnxDcpCardVrtrIfEventOvrflw notification is generated when a flood of distributed CPU protection network-interface events occur on a particular card and some of the events are lost due to event throttling mechanism.

Effect

Some network-interface notifications configured on the card may not be received.

Recovery

Notifications will resume once the event throttling ends.

tmnxDcpCardVrtrIfEventOvrflwClr

Table 45. tmnxDcpCardVrtrIfEventOvrflwClr properties

Property name

Value

Application name

CHASSIS

Event ID

2091

Event name

tmnxDcpCardVrtrIfEventOvrflwClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.79

Default severity

minor

Message format string

TODO

Cause

The tmnxDcpCardVrtrIfEventOvrflwClr notification is generated when the event throttling has ended for distributed CPU protection network-interface events on a particular card.

Effect

Notifications are received again since the event throttling has ended.

Recovery

There is no recovery for this notification.

tmnxDcpFpDynPoolUsageHiAlmClear

Table 46. tmnxDcpFpDynPoolUsageHiAlmClear properties

Property name

Value

Application name

CHASSIS

Event ID

2088

Event name

tmnxDcpFpDynPoolUsageHiAlmClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.76

Default severity

minor

Message format string

TODO

Cause

The tmnxDcpFpDynPoolUsageHiAlmClear notification is generated when the dynamic enforcement policer pool usage on the forwarding plane is no longer exhausted.

Effect

Dynamic enforcement policers are available in the free pool to be allocated when needed.

Recovery

There is no recovery required for this notification.

tmnxDcpFpDynPoolUsageHiAlmRaise

Table 47. tmnxDcpFpDynPoolUsageHiAlmRaise properties

Property name

Value

Application name

CHASSIS

Event ID

2087

Event name

tmnxDcpFpDynPoolUsageHiAlmRaise

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.75

Default severity

minor

Message format string

TODO

Cause

The tmnxDcpFpDynPoolUsageHiAlmRaise notification is generated when the dynamic enforcement policer pool usage on the forwarding plane is nearly exhausted.

Effect

Dynamic enforcement policers may not get allocated on the forwarding plane.

Recovery

This notification will be cleared when either the dynamic enforcement policer pool is increased or the usage drops.

tmnxEnvTempTooHigh

Table 48. tmnxEnvTempTooHigh properties

Property name

Value

Application name

CHASSIS

Event ID

2005

Event name

tmnxEnvTempTooHigh

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.2

Default severity

major

Message format string

$tmnxHwClass$ $tmnxChassisNotifyHwIndex$: temperature too high

Cause

Generated when the temperature sensor reading on an equipment object is greater than its configured threshold.

Effect

This could be causing intermittent errors and could also cause permanent damage to components.

Recovery

Remove or power down the affected cards, or improve the cooling to the node. More powerful fan trays may also be required.

tmnxEqBpEpromFail

Table 49. tmnxEqBpEpromFail properties

Property name

Value

Application name

CHASSIS

Event ID

2161

Event name

tmnxEqBpEpromFail

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.150

Default severity

critical

Message format string

CPM BP EPROM could not be accessed

Cause

The tmnxEqBpEpromFail notification is generated when the active CPM is no longer able to access the backplane EPROM due to a hardware defect.

Effect

The active CPM is at risk of failing to initialize after node reboot due to not being able to access the BP EPROM to read the chassis type.

Recovery

Contact Nokia customer support.

tmnxEqBpEpromFailClear

Table 50. tmnxEqBpEpromFailClear properties

Property name

Value

Application name

CHASSIS

Event ID

2162

Event name

tmnxEqBpEpromFailClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.151

Default severity

cleared

Message format string

CPM BP EPROM can now be accessed

Cause

The tmnxEqBpEpromFailClear notification is generated when the EPROM error condition is cleared.

Effect

N/A

Recovery

N/A

tmnxEqBpEpromWarning

Table 51. tmnxEqBpEpromWarning properties

Property name

Value

Application name

CHASSIS

Event ID

2163

Event name

tmnxEqBpEpromWarning

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.152

Default severity

minor

Message format string

One CPM BP EPROM could not be accessed

Cause

The tmnxEqBpEpromWarning notification is generated when the active CPM is no longer able to access one backplane EPROM due to a hardware defect, but a redundant EPROM is present and accessible.

Effect

There is no effect on system operation.

Recovery

No recovery action required.

tmnxEqBpEpromWarningClear

Table 52. tmnxEqBpEpromWarningClear properties

Property name

Value

Application name

CHASSIS

Event ID

2164

Event name

tmnxEqBpEpromWarningClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.153

Default severity

cleared

Message format string

All CPM BP EPROMs can be accessed

Cause

The tmnxEqBpEpromWarningClear notification is generated when the backplane EPROM warning condition is cleared.

Effect

N/A

Recovery

N/A

tmnxEqCardChipIfCellEvent

Table 53. tmnxEqCardChipIfCellEvent properties

Property name

Value

Application name

CHASSIS

Event ID

2103

Event name

tmnxEqCardChipIfCellEvent

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.90

Default severity

minor

Message format string

Possible messages:

  • $tmnxHwIndex$ experienced internal datapath cell errors

  • Slot $tmnxHwIndex$ experienced internal datapath cell errors on complex $tmnxCardComplexNumber$

Cause

The tmnxEqCardChipIfCellEvent notification is generated when an inter-chip interface (XPL2 bundle) experiences internal datapath cell errors.

Effect

Contact Nokia customer support.

Recovery

Contact Nokia customer support.

tmnxEqCardChipIfDownEvent

Table 54. tmnxEqCardChipIfDownEvent properties

Property name

Value

Application name

CHASSIS

Event ID

2102

Event name

tmnxEqCardChipIfDownEvent

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.89

Default severity

minor

Message format string

Possible messages:

  • $tmnxHwIndex$ experienced an internal datapath problem

  • Slot $tmnxHwIndex$ experienced an internal datapath problem on complex $tmnxCardComplexNumber$

Cause

The tmnxEqCardChipIfDownEvent notification is generated when an inter-chip interface (XPL2 bundle) experiences an internal datapath problem.

Effect

7750 SR/7450 ESS: The IOM or IMM will either remain operational or the card will reset along with its associated MDAs. 7950 XRS: The associated XMA (MDA CLI context) will either remain operational or it will reset. The XCM (CLI card context) will not reset.

Recovery

Contact Nokia customer support.

tmnxEqCardFailure

Table 55. tmnxEqCardFailure properties

Property name

Value

Application name

CHASSIS

Event ID

2001

Event name

tmnxEqCardFailure

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.7

Default severity

major

Message format string

Class $tmnxHwClass$ : failed, reason: $tmnxChassisNotifyCardFailureReason$

Cause

Generated when one of the cards in a chassis has failed. The card type may be IOM (or XCM), MDA (or XMA), SFM, CCM, CPM, Compact Flash, etc. The reason is indicated in the details of the log event or alarm, and also available in the tmnxChassisNotifyCardFailureReason attribute included in the SNMP notification.

Effect

The effect is dependent on the card that has failed. IOM (or XCM) or MDA (or XMA) failure will cause a loss of service for all services running on that card. A fabric failure can impact traffic to/from all cards. 7750 SR/7450 ESS - If the IOM/IMM fails then the two associated MDAs for the slot will also go down. 7950 XRS - If one out of two XMAs fails in a XCM slot then the XCM will remain up. If only one remaining operational XMA within a XCM slot fails, then the XCM will go into a booting operational state.

Recovery

Before taking any recovery steps, collect a tech-support file, then try resetting (clear) the card. If that doesn't work then try removing and then reinserting the card. If that doesn't work then replace the card.

tmnxEqCardFirmwareUpgraded

Table 56. tmnxEqCardFirmwareUpgraded properties

Property name

Value

Application name

CHASSIS

Event ID

2032

Event name

tmnxEqCardFirmwareUpgraded

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.40

Default severity

major

Message format string

Class $tmnxHwClass$ : firmware upgraded

Cause

Generated when a card is hot-inserted into the chassis and its firmware is automatically upgraded. The card type may be IOM or CPM module.

Effect

N/A

Recovery

N/A

tmnxEqCardInserted

Table 57. tmnxEqCardInserted properties

Property name

Value

Application name

CHASSIS

Event ID

2002

Event name

tmnxEqCardInserted

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.8

Default severity

minor

Message format string

Class $tmnxHwClass$ : inserted

Cause

Generated when a card is inserted into the chassis. The card type may be IOM, Fabric, MDA, MCM, CCM CPM module, compact flash module, etc.

Effect

N/A

Recovery

N/A

tmnxEqCardPChipCamEvent

Table 58. tmnxEqCardPChipCamEvent properties

Property name

Value

Application name

CHASSIS

Event ID

2076

Event name

tmnxEqCardPChipCamEvent

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.64

Default severity

critical

Message format string

A fault has been detected in the hardware on IOM $tmnxSlotNum$-forwarding engine $tmnxCardComplexNumber$

Cause

The tmnxEqCardPChipCamEvent notification is generated when either an IOM or a CPM experiences a persistent occurrence of a PChip CAM error. On a CPM card, the tmnxCardComplexNumber will be fixed to the value zero (0).

Effect

Contact Nokia customer support.

Recovery

Contact Nokia customer support.

tmnxEqCardPChipError

Table 59. tmnxEqCardPChipError properties

Property name

Value

Application name

CHASSIS

Event ID

2059

Event name

tmnxEqCardPChipError

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.47

Default severity

minor

Message format string

Slot $tmnxCardSlotNum$ detected $tmnxCardFwdDirection$ FCS errors on complex $tmnxCardComplexNumber$. Source card(s) of detected errors: $tmnxCardSrcSlotBitmap$

Cause

The tmnxEqCardPChipError notification is generated when persistent FCS errors are detected by the P chip in either the ingress or egress datapath/complex. The value tmnxCardSrcSlotBitmap is only used for the egress datapath/complex direction.

Effect

N/A

Recovery

N/A

tmnxEqCardPChipMemoryEvent

Table 60. tmnxEqCardPChipMemoryEvent properties

Property name

Value

Application name

CHASSIS

Event ID

2063

Event name

tmnxEqCardPChipMemoryEvent

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.51

Default severity

minor

Message format string

Possible messages:

  • $tmnxHwIndex$ experienced a pchip memory error occurrence

  • Slot $tmnxHwIndex$ experienced a pchip parity error occurrence on complex $tmnxCardComplexNumber$

Cause

The tmnxEqCardPChipMemoryEvent notification is generated when a P-chip experiences an occurrence of a memory error.

Effect

N/A

Recovery

N/A

tmnxEqCardQChipBufMemoryEvent

Table 61. tmnxEqCardQChipBufMemoryEvent properties

Property name

Value

Application name

CHASSIS

Event ID

2098

Event name

tmnxEqCardQChipBufMemoryEvent

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.86

Default severity

minor

Message format string

Possible messages:

  • $tmnxHwIndex$ experienced a Q-chip buffer memory error occurrence

  • Slot $tmnxHwIndex$ experienced a Q-chip buffer memory error occurrence on complex $tmnxCardComplexNumber$

Cause

The tmnxEqCardQChipBufMemoryEvent notification is generated when a Q-chip experiences an occurrence of a buffer memory error.

Effect

Contact Nokia customer support.

Recovery

Contact Nokia customer support.

tmnxEqCardQChipIntMemoryEvent

Table 62. tmnxEqCardQChipIntMemoryEvent properties

Property name

Value

Application name

CHASSIS

Event ID

2101

Event name

tmnxEqCardQChipIntMemoryEvent

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.88

Default severity

minor

Message format string

Possible messages:

  • $tmnxHwIndex$ experienced a qchip internal memory error occurrence

  • Slot $tmnxHwIndex$ experienced a qchip internal memory error occurrence on complex $tmnxCardComplexNumber$

Cause

The tmnxEqCardQChipIntMemoryEvent notification is generated when a Q-chip experiences an occurrence of an internal memory error.

Effect

Contact Nokia customer support.

Recovery

Contact Nokia customer support.

tmnxEqCardQChipStatsMemoryEvent

Table 63. tmnxEqCardQChipStatsMemoryEvent properties

Property name

Value

Application name

CHASSIS

Event ID

2099

Event name

tmnxEqCardQChipStatsMemoryEvent

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.87

Default severity

minor

Message format string

Possible messages:

  • $tmnxHwIndex$ experienced a Q-chip statistics memory error occurrence

  • Slot $tmnxHwIndex$ experienced a Q-chip statistics memory error occurrence on complex $tmnxCardComplexNumber$

Cause

The tmnxEqCardQChipStatsMemoryEvent notification is generated when a Q-chip experiences an occurrence of a statistics memory error.

Effect

Contact Nokia customer support.

Recovery

Contact Nokia customer support.

tmnxEqCardRemoved

Table 64. tmnxEqCardRemoved properties

Property name

Value

Application name

CHASSIS

Event ID

2003

Event name

tmnxEqCardRemoved

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.9

Default severity

major

Message format string

Class $tmnxHwClass$ : removed

Cause

Generated when a card is removed from the chassis. The card type may be IOM (or XCM), MDA (or XMA), SFM, CCM, CPM, Compact Flash, etc.

Effect

The effect is dependent on the card that has been removed. IOM (or XCM) or MDA (or XMA) removal will cause a loss of service for all services running on that card. A fabric removal can impact traffic to/from all cards.

Recovery

Before taking any recovery steps collect a tech-support file, then try reinserting the card. If that doesn't work then replace the card.

tmnxEqCardSoftResetAlarm

Table 65. tmnxEqCardSoftResetAlarm properties

Property name

Value

Application name

CHASSIS

Event ID

2060

Event name

tmnxEqCardSoftResetAlarm

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.48

Default severity

minor

Message format string

Slot $tmnxHwIndex$ entered soft-reset state $tmnxCardSoftResetState$

Cause

The tmnxEqCardSoftResetAlarm notification is generated when an IOM card enters and exits the 'soft-reset' state.

Effect

N/A

Recovery

N/A

tmnxEqCardTChipParityEvent

Table 66. tmnxEqCardTChipParityEvent properties

Property name

Value

Application name

CHASSIS

Event ID

2110

Event name

tmnxEqCardTChipParityEvent

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.97

Default severity

minor

Message format string

Slot $tmnxHwIndex$ experienced a T-chip memory error occurrence on complex $tmnxCardComplexNumber$

Cause

The tmnxEqCardTChipParityEvent notification is generated when a T-chip experiences an occurrence of an internal memory error.

Effect

Contact Nokia customer support.

Recovery

Contact Nokia customer support.

tmnxEqDataPathFailureProtImpact

Table 67. tmnxEqDataPathFailureProtImpact properties

Property name

Value

Application name

CHASSIS

Event ID

2126

Event name

tmnxEqDataPathFailureProtImpact

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.113

Default severity

minor

Message format string

$tmnxHwClass$ $tmnxHwIndex$ experienced a datapath failure which impacted a protocol.

Cause

The tmnxEqDataPathFailureProtImpact notification is generated when a slot experienced a data path failure which impacted a protocol.

Effect

Services-related data associated with the impacted protocol may be lost.

Recovery

N/A

tmnxEqFlashDataLoss

Table 68. tmnxEqFlashDataLoss properties

Property name

Value

Application name

CHASSIS

Event ID

2023

Event name

tmnxEqFlashDataLoss

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.32

Default severity

major

Message format string

Class $tmnxHwClass$ : probable data loss

Cause

tmnxEqFlashDataLoss is generated when an error occurs while data was being written to the compact flash. This notification indicates a probable data loss.

Effect

N/A

Recovery

N/A

tmnxEqFlashDiskFull

Table 69. tmnxEqFlashDiskFull properties

Property name

Value

Application name

CHASSIS

Event ID

2024

Event name

tmnxEqFlashDiskFull

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.33

Default severity

major

Message format string

Class $tmnxHwClass$ : $tmnxChassisNotifyDiskFullReason$

Cause

tmnxEqFlashDiskFull is generated when there is no space left on the compact flash. No more data can be written to it.

Effect

N/A

Recovery

N/A

tmnxEqFpgaSoftError

Table 70. tmnxEqFpgaSoftError properties

Property name

Value

Application name

CHASSIS

Event ID

2200

Event name

tmnxEqFpgaSoftError

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.211

Default severity

minor

Message format string

Slot $tmnxHwIndex$ detected an SEU event

Cause

The tmnxEqFpgaSoftError notification is for experimental use only and should remain suppressed unless advised otherwise by Nokia customer support.

Effect

Contact Nokia customer support.

Recovery

Contact Nokia customer support.

tmnxEqHwEnhancedCapability

Table 71. tmnxEqHwEnhancedCapability properties

Property name

Value

Application name

CHASSIS

Event ID

2078

Event name

tmnxEqHwEnhancedCapability

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.66

Default severity

major

Message format string

CPM Upgrade In Progress. Card in slot $tmnxCardSlotNum$ has enhanced capabilities.

Cause

The tmnxEqHwEnhancedCapability notification is generated when the hardware, specified by the supplied objects, consists of enhanced capabilities as compared to the active hardware.

Effect

The system behaves normally under this situation, however, switching to the newer hardware will put the system in an incompatible state with the currently active hardware. That is, once this device takes activity, the lesser capable hardware will fail to communicate with it. In this mode, the system is deemed in a 'one-way upgrade' scenario.

Recovery

Two modes of recovery exist for this notification: 1) Remove the enhanced hardware, and supply a more compatible device (status quo) with the active hardware. 2) Switch to the enhanced device, and replace the older hardware with a similarly enhanced device (upgrade).

tmnxEqHwEventDetected

Table 72. tmnxEqHwEventDetected properties

Property name

Value

Application name

CHASSIS

Event ID

2207

Event name

tmnxEqHwEventDetected

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.218

Default severity

minor

Message format string

$tmnxHwClass$ $tmnxChassisNotifyHwIndex$: $tmnxEqNotifyHwEventType$ event detected. (detail: $tmnxEqNotifyHwEventDetail$, action:$tmnxEqNotifyHwEventAction$)

Cause

Generated when events or errors being monitored are detected by hardware component.

Effect

The system will perform the configured action on the hardware component.

Recovery

Check hardware component.

tmnxEqLowSwitchFabricCap

Table 73. tmnxEqLowSwitchFabricCap properties

Property name

Value

Application name

CHASSIS

Event ID

2104

Event name

tmnxEqLowSwitchFabricCap

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.91

Default severity

major

Message format string

The switch fabric capacity is less than the forwarding capacity of $tmnxHwClass$ $tmnxHwIndex$ due to errors in fabric links.

Cause

The tmnxEqLowSwitchFabricCap alarm is generated when the total switch fabric capacity becomes less than the IOM capacity due to link failures. At least one of the taps on the IOM is below 100% capacity.

Effect

There is diminished switch fabric capacity to forward service-impacting information.

Recovery

If the system does not self-recover, the IOM must be rebooted.

tmnxEqLowSwitchFabricCapClear

Table 74. tmnxEqLowSwitchFabricCapClear properties

Property name

Value

Application name

CHASSIS

Event ID

2105

Event name

tmnxEqLowSwitchFabricCapClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.92

Default severity

major

Message format string

The switch fabric capacity alarm for $tmnxHwClass$ $tmnxHwIndex$ was cleared.

Cause

The tmnxEqLowSwitchFabricCapClear notification is generated when the link failures that resulted in the tmnxEqLowSwitchFabricCap alarm to be raised have been resolved.

Effect

There is sufficient switch fabric capacity to forward service-impacting information.

Recovery

N/A

tmnxEqMdaCfgNotCompatible

Table 75. tmnxEqMdaCfgNotCompatible properties

Property name

Value

Application name

CHASSIS

Event ID

2056

Event name

tmnxEqMdaCfgNotCompatible

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.44

Default severity

major

Message format string

Class $tmnxHwClass$ : configuration not compatible with equipped MDA

Cause

Generated when a supported MDA is inserted into a slot of an IOM, the MDA is compatible with the currently provisioned MDA, but the current configuration on the MDA's ports is not compatible with the inserted MDA.

Effect

Though services can still be created, if the tmnxMdaNotifyType is the same as the tmnxMDAEquippedType then the MDA will fail to operate as configured and will be in a failed state.

Recovery

Change the configuration to reflect the capabilities of the MDA port, or switch out/re-provision the MDA for one that is compatible.

tmnxEqMdaIngrXplError

Table 76. tmnxEqMdaIngrXplError properties

Property name

Value

Application name

CHASSIS

Event ID

2129

Event name

tmnxEqMdaIngrXplError

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.116

Default severity

minor

Message format string

MDA $tmnxCardSlotNum$/ $tmnxEqMdaSlotNum$ experienced an ingress XPL error occurrence.

Cause

The tmnxEqMdaIngrXplError notification is generated when an MDA exhibits persistent ingress XPL errors.

Effect

Contact Nokia customer support.

Recovery

Contact Nokia customer support.

tmnxEqMdaSyncENotCompatible

Table 77. tmnxEqMdaSyncENotCompatible properties

Property name

Value

Application name

CHASSIS

Event ID

2061

Event name

tmnxEqMdaSyncENotCompatible

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.49

Default severity

major

Message format string

Provisioned synchronous ethernet not compatible with equipped MDA

Cause

The tmnxEqMdaSyncENotCompatible notification is generated when an MDA card is inserted into a slot of an IOM. The MDA is compatible with the currently provisioned MDA, but the currently configured synchronous ethernet, tmnxMDASynchronousEthernet, is not compatible with the inserted MDA.

Effect

Though services can still be created, if the tmnxMdaNotifyType is the same as the tmnxMDAEquippedType then the MDA will fail to operate as configured and will be in a failed state.

Recovery

Change the configuration to reflect the capabilities of the MDA port, or switch out/re-provision the MDA for one that is compatible.

tmnxEqMdaXplError

Table 78. tmnxEqMdaXplError properties

Property name

Value

Application name

CHASSIS

Event ID

2058

Event name

tmnxEqMdaXplError

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.46

Default severity

minor

Message format string

MDA $tmnxCardSlotNum$/ $tmnxMDASlotNum$ experienced an egress XPL error occurrence.

Cause

The tmnxEqMdaXplError notification is generated when an MDA exhibits persistent egress XPL Errors.

Effect

N/A

Recovery

N/A

tmnxEqMgmtEthRedStandbyClear

Table 79. tmnxEqMgmtEthRedStandbyClear properties

Property name

Value

Application name

CHASSIS

Event ID

2137

Event name

tmnxEqMgmtEthRedStandbyClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.122

Default severity

minor

Message format string

The active CPM's management Ethernet port $tmnxChassisNotifyMgmtEthRedPort$ is serving as the system's management Ethernet port.

Cause

The tmnxEqMgmtEthRedStandbyClear notification is generated when the active CPM's management Ethernet port goes operationally up and the management Ethernet port reverts from the standby CPM to the active CPM.

Effect

The management of the node is operating from the active CPM's management Ethernet port and is redundant.

Recovery

No recovery required.

tmnxEqMgmtEthRedStandbyRaise

Table 80. tmnxEqMgmtEthRedStandbyRaise properties

Property name

Value

Application name

CHASSIS

Event ID

2136

Event name

tmnxEqMgmtEthRedStandbyRaise

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.121

Default severity

minor

Message format string

The standby CPM's management Ethernet port $tmnxChassisNotifyMgmtEthRedPort$ is serving as the system's management Ethernet port.

Cause

The tmnxEqMgmtEthRedStandbyRaise notification is generated when the active CPM's management Ethernet port goes operationally down and the standby CPM's management Ethernet port is operationally up and now serving as the system's management Ethernet port.

Effect

The management Ethernet port is no longer redundant. The node can be managed via the standby CPM's management Ethernet port only.

Recovery

Bring the active CPM's management Ethernet port operationally up.

tmnxEqOperStateChange

Table 81. tmnxEqOperStateChange properties

Property name

Value

Application name

CHASSIS

Event ID

2055

Event name

tmnxEqOperStateChange

SNMP notification prefix and OID

TIMETRA-SYSTEM-MIB.tmnxSysNotifications.85

Default severity

major

Message format string

$tmnxNotifyObjectName$ changed operational state: $tmnxNotifyRowOperState$

Cause

The tmnxEqOperStateChange notification is generated when a change occurred in the operational state on the piece of hardware.

Effect

If the state has changed to out of service, then all ports and services associated with the module change to out of service and traffic is impacted.

Recovery

Investigation is required to determine the cause of the change.

tmnxEqPhysChassisFanFailure

Table 82. tmnxEqPhysChassisFanFailure properties

Property name

Value

Application name

CHASSIS

Event ID

2148

Event name

tmnxEqPhysChassisFanFailure

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.135

Default severity

critical

Message format string

Chassis $tmnxPhysChassisNum$ fan $tmnxPhysChassisFanIndex$ failure

Cause

The tmnxEqPhysChassisFanFailure notification is generated when one of the fans in a fan tray fails on a particular physical chassis.

Effect

The fan is no longer operational.

Recovery

Insert a new fan.

tmnxEqPhysChassisFanFailureClear

Table 83. tmnxEqPhysChassisFanFailureClear properties

Property name

Value

Application name

CHASSIS

Event ID

2149

Event name

tmnxEqPhysChassisFanFailureClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.136

Default severity

cleared

Message format string

Chassis $tmnxPhysChassisNum$ fan $tmnxPhysChassisFanIndex$ failure cleared

Cause

The tmnxEqPhysChassisFanFailureClear notification is generated when the fan failure is cleared on the particular physical chassis.

Effect

The fan is operational again.

Recovery

There is no recovery for this notification.

tmnxEqPhysChassPowerSupAcFail

Table 84. tmnxEqPhysChassPowerSupAcFail properties

Property name

Value

Application name

CHASSIS

Event ID

2140

Event name

tmnxEqPhysChassPowerSupAcFail

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.127

Default severity

critical

Message format string

Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ AC failure

Cause

The tmnxEqPhysChassPowerSupAcFail notification is generated when an AC failure occurs on the power supply.

Effect

The power supply is no longer operational.

Recovery

Insert a new power supply.

tmnxEqPhysChassPowerSupAcFailClr

Table 85. tmnxEqPhysChassPowerSupAcFailClr properties

Property name

Value

Application name

CHASSIS

Event ID

2141

Event name

tmnxEqPhysChassPowerSupAcFailClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.128

Default severity

cleared

Message format string

Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ AC failure cleared

Cause

The tmnxEqPhysChassPowerSupAcFailClr notification is generated when the AC failure is cleared on the power supply.

Effect

The power supply is operational again.

Recovery

There is no recovery for this notification.

tmnxEqPhysChassPowerSupDcFail

Table 86. tmnxEqPhysChassPowerSupDcFail properties

Property name

Value

Application name

CHASSIS

Event ID

2142

Event name

tmnxEqPhysChassPowerSupDcFail

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.129

Default severity

critical

Message format string

Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ DC failure

Cause

The tmnxEqPhysChassPowerSupDcFail notification is generated when a DC failure occurs on the power supply.

Effect

The power supply is no longer operational.

Recovery

Insert a new power supply.

tmnxEqPhysChassPowerSupDcFailClr

Table 87. tmnxEqPhysChassPowerSupDcFailClr properties

Property name

Value

Application name

CHASSIS

Event ID

2143

Event name

tmnxEqPhysChassPowerSupDcFailClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.130

Default severity

cleared

Message format string

Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ DC failure cleared

Cause

The tmnxEqPhysChassPowerSupDcFailClr notification is generated when the DC failure is cleared on the power supply.

Effect

The power supply is operational again.

Recovery

There is no recovery for this notification.

tmnxEqPhysChassPowerSupInFail

Table 88. tmnxEqPhysChassPowerSupInFail properties

Property name

Value

Application name

CHASSIS

Event ID

2144

Event name

tmnxEqPhysChassPowerSupInFail

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.131

Default severity

critical

Message format string

Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ input failure

Cause

The tmnxEqPhysChassPowerSupInFail notification is generated when an input failure occurs on the power supply.

Effect

The power supply is no longer operational.

Recovery

Check input feed and/or insert a new power supply.

tmnxEqPhysChassPowerSupInFailClr

Table 89. tmnxEqPhysChassPowerSupInFailClr properties

Property name

Value

Application name

CHASSIS

Event ID

2145

Event name

tmnxEqPhysChassPowerSupInFailClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.132

Default severity

cleared

Message format string

Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ input failure cleared

Cause

The tmnxEqPhysChassPowerSupInFailClr notification is generated when the input failure is cleared on the power supply.

Effect

The power supply is operational again.

Recovery

There is no recovery for this notification.

tmnxEqPhysChassPowerSupOutFail

Table 90. tmnxEqPhysChassPowerSupOutFail properties

Property name

Value

Application name

CHASSIS

Event ID

2146

Event name

tmnxEqPhysChassPowerSupOutFail

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.133

Default severity

critical

Message format string

Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ output failure

Cause

The tmnxEqPhysChassPowerSupOutFail notification is generated when an output failure occurs on the power supply.

Effect

The power supply is no longer operational.

Recovery

Insert a new power supply.

tmnxEqPhysChassPowerSupOutFailCl

Table 91. tmnxEqPhysChassPowerSupOutFailCl properties

Property name

Value

Application name

CHASSIS

Event ID

2147

Event name

tmnxEqPhysChassPowerSupOutFailCl

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.134

Default severity

cleared

Message format string

Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ output failure cleared

Cause

The tmnxEqPhysChassPowerSupOutFailCl notification is generated when an output failure is cleared on the power supply.

Effect

The power supply is operational again.

Recovery

There is no recovery for this notification.

tmnxEqPhysChassPowerSupOvrTmp

Table 92. tmnxEqPhysChassPowerSupOvrTmp properties

Property name

Value

Application name

CHASSIS

Event ID

2138

Event name

tmnxEqPhysChassPowerSupOvrTmp

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.125

Default severity

critical

Message format string

Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ over temperature

Cause

The tmnxEqPhysChassPowerSupOvrTmp notification is generated when a power supply's temperature surpasses the threshold of the particular physical chassis.

Effect

The power supply is no longer operational.

Recovery

Check input feed and/or insert a new power supply.

tmnxEqPhysChassPowerSupOvrTmpClr

Table 93. tmnxEqPhysChassPowerSupOvrTmpClr properties

Property name

Value

Application name

CHASSIS

Event ID

2139

Event name

tmnxEqPhysChassPowerSupOvrTmpClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.126

Default severity

cleared

Message format string

Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ over temperature cleared

Cause

The tmnxEqPhysChassPowerSupOvrTmpClr notification is generated when a power supply's temperature is reduced below the threshold of the particular physical chassis.

Effect

The power supply is operational again.

Recovery

There is no recovery for this notification.

tmnxEqPowerCapacityExceeded

Table 94. tmnxEqPowerCapacityExceeded properties

Property name

Value

Application name

CHASSIS

Event ID

2092

Event name

tmnxEqPowerCapacityExceeded

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.80

Default severity

minor

Message format string

The system has reached maximum power capacity $tmnxChassisNotifyPowerCapacity$ watts

Cause

The tmnxEqPowerCapacityExceeded alarm is generated when a device needs power to boot, but there is not enough power capacity to support the device.

Effect

A non-powered device will not boot until the power capacity is increased to support the device.

Recovery

Add a new power supply to the system or change the faulty power supply for a working one.

tmnxEqPowerCapacityExceededClear

Table 95. tmnxEqPowerCapacityExceededClear properties

Property name

Value

Application name

CHASSIS

Event ID

2093

Event name

tmnxEqPowerCapacityExceededClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.81

Default severity

minor

Message format string

The system power capacity is sufficient to support installed devices

Cause

The tmnxEqPowerCapacityExceededClear notification is generated when the available power capacity exceeds the required power to boot all inserted devices.

Effect

Devices that failed to boot due to power constrains, power up.

Recovery

N/A

tmnxEqPowerLostCapacity

Table 96. tmnxEqPowerLostCapacity properties

Property name

Value

Application name

CHASSIS

Event ID

2094

Event name

tmnxEqPowerLostCapacity

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.82

Default severity

major

Message format string

The system can no longer support configured devices. Power capacity dropped to $tmnxChassisNotifyPowerCapacity$ watts

Cause

The tmnxEqPowerLostCapacity alarm is generated when a power supply fails or is removed which puts the system in an overloaded situation.

Effect

Devices are powered off in order of lowest power priority (tmnxMDAHwPowerPriority) until the available power capacity can support the powered devices.

Recovery

Add a new power supply to the system or change the faulty power supply for a working one.

tmnxEqPowerLostCapacityClear

Table 97. tmnxEqPowerLostCapacityClear properties

Property name

Value

Application name

CHASSIS

Event ID

2095

Event name

tmnxEqPowerLostCapacityClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.83

Default severity

major

Message format string

The system has reached a sustainable power capacity.

Cause

The tmnxEqPowerLostCapacityClear notification is generated when the available power capacity exceeds the required power to boot all inserted devices.

Effect

Devices that powered off due to power constrains, power up.

Recovery

N/A

tmnxEqPowerOverloadState

Table 98. tmnxEqPowerOverloadState properties

Property name

Value

Application name

CHASSIS

Event ID

2096

Event name

tmnxEqPowerOverloadState

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.84

Default severity

critical

Message format string

The system has reached critical power capacity. Increase available power now.

Cause

The tmnxEqPowerOverloadState alarm is generated when the overloaded power capacity cannot support the power requirements and there are no further devices that can be powered off.

Effect

The system runs a risk of experiencing brownouts while the available power capacity does not meet the required power consumption.

Recovery

Add power capacity or manually shut down devices until the power capacity meets the power needs.

tmnxEqPowerOverloadStateClear

Table 99. tmnxEqPowerOverloadStateClear properties

Property name

Value

Application name

CHASSIS

Event ID

2097

Event name

tmnxEqPowerOverloadStateClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.85

Default severity

critical

Message format string

The system has reached a sustainable power capacity for critical equipment.

Cause

The tmnxEqPowerOverloadStateClear notification is generated when the available power capacity meets or exceeds the power needs of the powered on devices.

Effect

N/A

Recovery

N/A

tmnxEqPowerSafetyAlertClear

Table 100. tmnxEqPowerSafetyAlertClear properties

Property name

Value

Application name

CHASSIS

Event ID

2107

Event name

tmnxEqPowerSafetyAlertClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.94

Default severity

minor

Message format string

Possible messages:

  • The system power capacity safety alert for zone $tmnxChassisPwrMgmtZone$ has been disabled.

  • The system power capacity for zone $tmnxChassisPwrMgmtZone$ meets or exceeds the configured safety alert threshold of $tmnxChassisPwrMgmtSafetyAlert$ watts.

Cause

The tmnxEqPowerSafetyAlertClear notification is generated when the system power capacity raises above the configured safety alert threshold.

Effect

This event is for notification only.

Recovery

N/A

tmnxEqPowerSafetyAlertThreshold

Table 101. tmnxEqPowerSafetyAlertThreshold properties

Property name

Value

Application name

CHASSIS

Event ID

2106

Event name

tmnxEqPowerSafetyAlertThreshold

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.93

Default severity

minor

Message format string

The system power capacity for zone $tmnxChassisPwrMgmtZone$ dropped below the configured safety alert threshold of $tmnxChassisPwrMgmtSafetyAlert$ watts.

Cause

The tmnxEqPowerSafetyAlertThreshold notification is generated when the system power capacity drops below the configured safety alert threshold.

Effect

This event is for notification only.

Recovery

N/A

tmnxEqPowerSafetyLevelClear

Table 102. tmnxEqPowerSafetyLevelClear properties

Property name

Value

Application name

CHASSIS

Event ID

2109

Event name

tmnxEqPowerSafetyLevelClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.96

Default severity

minor

Message format string

The peak nodal power for zone $tmnxChassisPwrMgmtZone$ consumption dropped below the configured safety level threshold of $tmnxChassisPwrMgmtSafetyLevel$ percent

Cause

The tmnxEqPowerSafetyLevelClear notification is generated when the peak nodal power consumption drops below the configured safety level threshold.

Effect

This event is for notification only.

Recovery

N/A

tmnxEqPowerSafetyLevelThreshold

Table 103. tmnxEqPowerSafetyLevelThreshold properties

Property name

Value

Application name

CHASSIS

Event ID

2108

Event name

tmnxEqPowerSafetyLevelThreshold

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.95

Default severity

minor

Message format string

The peak nodal power for zone $tmnxChassisPwrMgmtZone$ consumption exceeded the configured safety level threshold of $tmnxChassisPwrMgmtSafetyLevel$ percent

Cause

The tmnxEqPowerSafetyLevelThreshold notification is generated when the peak nodal power consumption exceeds the configured safety level threshold.

Effect

This event is for notification only.

Recovery

N/A

tmnxEqPowerSupplyInserted

Table 104. tmnxEqPowerSupplyInserted properties

Property name

Value

Application name

CHASSIS

Event ID

2010

Event name

tmnxEqPowerSupplyInserted

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.4

Default severity

major

Message format string

$tmnxChassisNotifyHwIndex$ inserted

Cause

Generated when one of the chassis' power supplies is inserted.

Effect

N/A

Recovery

N/A

tmnxEqPowerSupplyRemoved

Table 105. tmnxEqPowerSupplyRemoved properties

Property name

Value

Application name

CHASSIS

Event ID

2011

Event name

tmnxEqPowerSupplyRemoved

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.5

Default severity

major

Message format string

$tmnxChassisNotifyHwIndex$, power lost

Cause

The tmnxEqPowerSupplyRemoved notification is generated when one of the power supplies is removed from the chassis or low input voltage is detected. The operating voltage range for the 7750 SR-7 and 7750 SR-12 is -40 to -72 VDC. The notification is generated if the system detects that the voltage of the power supply has dropped to -42.5 VDC.

Effect

Reduced power can cause intermittent errors and could also cause permanent damage to components.

Recovery

Reinsert the power supply or raise the input voltage above -42.5 VDC.

tmnxEqProvPowerCapacityAlm

Table 106. tmnxEqProvPowerCapacityAlm properties

Property name

Value

Application name

CHASSIS

Event ID

2115

Event name

tmnxEqProvPowerCapacityAlm

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.102

Default severity

minor

Message format string

The provisioned power capacity can no longer support configured devices.

Cause

The tmnxEqProvPowerCapacityAlm notification is generated if a power zone's provisioned power capacity can no longer support configured devices.

Effect

There is an increased risk of device power outages that may be service affecting.

Recovery

Increase the provisioned power capacity.

tmnxEqProvPowerCapacityAlmClr

Table 107. tmnxEqProvPowerCapacityAlmClr properties

Property name

Value

Application name

CHASSIS

Event ID

2116

Event name

tmnxEqProvPowerCapacityAlmClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.103

Default severity

minor

Message format string

The provisioned power capacity now supports configured devices.

Cause

The tmnxEqProvPowerCapacityAlmClr notification is generated when the power zone's provisioned power capacity can support configured devices.

Effect

All configured devices in the power zone have enough provisioned power capacity.

Recovery

N/A

tmnxEqSyncIfTimingBITS2Alarm

Table 108. tmnxEqSyncIfTimingBITS2Alarm properties

Property name

Value

Application name

CHASSIS

Event ID

2073

Event name

tmnxEqSyncIfTimingBITS2Alarm

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.61

Default severity

minor

Message format string

Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on BITS 2 reference

Cause

Generated when an alarm condition on the BITS 2 timing reference is detected. This notification will have the same indices as those of the tmnxCpmCardTable.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingBITS2AlarmClr

Table 109. tmnxEqSyncIfTimingBITS2AlarmClr properties

Property name

Value

Application name

CHASSIS

Event ID

2074

Event name

tmnxEqSyncIfTimingBITS2AlarmClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.62

Default severity

minor

Message format string

Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on BITS 2 reference cleared

Cause

Generated when an alarm condition on the BITS 2 timing reference is cleared. This notification will have the same indices as those of the tmnxCpmCardTable.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingBITS2Quality

Table 110. tmnxEqSyncIfTimingBITS2Quality properties

Property name

Value

Application name

CHASSIS

Event ID

2071

Event name

tmnxEqSyncIfTimingBITS2Quality

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.59

Default severity

minor

Message format string

Synchronous Timing interface, reference BITS2 received quality level $tmnxSyncIfTimingBITS2RxQltyLevel$

Cause

Generated when there is a change of the received quality level on the second bits interface.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingBITSAlarm

Table 111. tmnxEqSyncIfTimingBITSAlarm properties

Property name

Value

Application name

CHASSIS

Event ID

2030

Event name

tmnxEqSyncIfTimingBITSAlarm

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.38

Default severity

minor

Message format string

Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on BITS$bits-two-supported$ reference

Cause

Generated when an alarm condition on the BITS timing reference is detected. This notification will have the same indices as those of the tmnxCpmCardTable.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingBITSAlarmClear

Table 112. tmnxEqSyncIfTimingBITSAlarmClear properties

Property name

Value

Application name

CHASSIS

Event ID

2031

Event name

tmnxEqSyncIfTimingBITSAlarmClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.39

Default severity

minor

Message format string

Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on BITS$bits-two-supported$ reference cleared

Cause

Generated when an alarm condition on the BITS timing reference is cleared. This notification will have the same indices as those of the tmnxCpmCardTable.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingBITSOutRefChg

Table 113. tmnxEqSyncIfTimingBITSOutRefChg properties

Property name

Value

Application name

CHASSIS

Event ID

2075

Event name

tmnxEqSyncIfTimingBITSOutRefChg

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.63

Default severity

minor

Message format string

Synchronous Timing interface, BITS output timing reference changed to $tmnxSyncIfTimingBITSOutRefSel$

Cause

Generated when the BITS Out timing reference selection changes.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingBITSQuality

Table 114. tmnxEqSyncIfTimingBITSQuality properties

Property name

Value

Application name

CHASSIS

Event ID

2070

Event name

tmnxEqSyncIfTimingBITSQuality

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.58

Default severity

minor

Message format string

Synchronous Timing interface, reference BITS $bits-two-supported$ received quality level $tmnxSyncIfTimingBITSRxQltyLevel$

Cause

Generated when there is a change of the received quality level on the bits interface.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingGnss2Alarm

Table 115. tmnxEqSyncIfTimingGnss2Alarm properties

Property name

Value

Application name

CHASSIS

Event ID

2227

Event name

tmnxEqSyncIfTimingGnss2Alarm

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.238

Default severity

minor

Message format string

Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on GNSS2 reference

Cause

Generated when an alarm condition on the gnss2 timing reference is detected. The type of alarm (los, oof, etc) is indicated in the details of the log event or alarm, and is also available in the tmnxSyncIfTimingNotifyAlarm attribute included in the SNMP notification. The SNMP notification will have the same indices as those of the tmnxCpmCardTable.

Effect

Timing reference gnss2 cannot be used as a source of timing into the central clock.

Recovery

Address issues with the signal associated with timing reference gnss2.

tmnxEqSyncIfTimingGnss2AlarmClr

Table 116. tmnxEqSyncIfTimingGnss2AlarmClr properties

Property name

Value

Application name

CHASSIS

Event ID

2229

Event name

tmnxEqSyncIfTimingGnss2AlarmClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.240

Default severity

minor

Message format string

Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on GNSS2 reference cleared

Cause

Generated when an alarm condition on the gnss2 timing reference is cleared. This notification will have the same indices as those of the tmnxCpmCardTable.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingGnss2Quality

Table 117. tmnxEqSyncIfTimingGnss2Quality properties

Property name

Value

Application name

CHASSIS

Event ID

2225

Event name

tmnxEqSyncIfTimingGnss2Quality

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.236

Default severity

minor

Message format string

Synchronous Timing interface, reference GNSS2 received quality level $tmnxSyncIfTimingGnss2RxQltyLevel$

Cause

Generated when there is a change of the received quality level on timing reference gnss2.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingGnssAlarm

Table 118. tmnxEqSyncIfTimingGnssAlarm properties

Property name

Value

Application name

CHASSIS

Event ID

2226

Event name

tmnxEqSyncIfTimingGnssAlarm

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.237

Default severity

minor

Message format string

Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on GNSS reference

Cause

Generated when an alarm condition on the gnss timing reference is detected. The type of alarm (los, oof, etc) is indicated in the details of the log event or alarm, and is also available in the tmnxSyncIfTimingNotifyAlarm attribute included in the SNMP notification. The SNMP notification will have the same indices as those of the tmnxCpmCardTable.

Effect

Timing reference gnss cannot be used as a source of timing into the central clock.

Recovery

Address issues with the signal associated with timing reference gnss.

tmnxEqSyncIfTimingGnssAlarmClr

Table 119. tmnxEqSyncIfTimingGnssAlarmClr properties

Property name

Value

Application name

CHASSIS

Event ID

2228

Event name

tmnxEqSyncIfTimingGnssAlarmClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.239

Default severity

minor

Message format string

Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on GNSS reference cleared

Cause

Generated when an alarm condition on the gnss timing reference is cleared. This notification will have the same indices as those of the tmnxCpmCardTable.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingGnssQuality

Table 120. tmnxEqSyncIfTimingGnssQuality properties

Property name

Value

Application name

CHASSIS

Event ID

2224

Event name

tmnxEqSyncIfTimingGnssQuality

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.235

Default severity

minor

Message format string

Synchronous Timing interface, reference GNSS received quality level $tmnxSyncIfTimingGnssRxQltyLevel$

Cause

Generated when there is a change of the received quality level on timing reference gnss.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingHoldover

Table 121. tmnxEqSyncIfTimingHoldover properties

Property name

Value

Application name

CHASSIS

Event ID

2017

Event name

tmnxEqSyncIfTimingHoldover

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.26

Default severity

critical

Message format string

Synchronous Timing interface in holdover state

Cause

Generated when the synchronous equipment timing subsystem transitions into a holdover state. This notification will have the same indices as those of the tmnxCpmCardTable.

Effect

Any node-timed ports will have very slow frequency drift limited by the central clock oscillator stability. The oscillator meets the holdover requirements of a Stratum 3 and G.813 Option 1 clock.

Recovery

Address issues with the central clock input references.

tmnxEqSyncIfTimingHoldoverClear

Table 122. tmnxEqSyncIfTimingHoldoverClear properties

Property name

Value

Application name

CHASSIS

Event ID

2018

Event name

tmnxEqSyncIfTimingHoldoverClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.27

Default severity

critical

Message format string

Synchronous Timing interface holdover state cleared

Cause

Generated when the synchronous equipment timing subsystem transitions out of the holdover state. This notification will have the same indices as those of the tmnxCpmCardTable.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingPTPAlarm

Table 123. tmnxEqSyncIfTimingPTPAlarm properties

Property name

Value

Application name

CHASSIS

Event ID

2080

Event name

tmnxEqSyncIfTimingPTPAlarm

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.68

Default severity

minor

Message format string

Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on PTP reference

Cause

Generated when an alarm condition on the Precision Timing Protocol (PTP) timing reference is detected. This notification will have the same indices as those of the tmnxCpmCardTable.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingPTPAlarmClr

Table 124. tmnxEqSyncIfTimingPTPAlarmClr properties

Property name

Value

Application name

CHASSIS

Event ID

2081

Event name

tmnxEqSyncIfTimingPTPAlarmClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.69

Default severity

minor

Message format string

Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on PTP reference cleared

Cause

Generated when an alarm condition on the Precision Timing Protocol (PTP) timing reference is cleared. This notification will have the same indices as those of the tmnxCpmCardTable.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingPTPQuality

Table 125. tmnxEqSyncIfTimingPTPQuality properties

Property name

Value

Application name

CHASSIS

Event ID

2079

Event name

tmnxEqSyncIfTimingPTPQuality

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.67

Default severity

minor

Message format string

Synchronous Timing interface, reference PTP received quality level $tmnxSyncIfTimingPTPRxQltyLevel$

Cause

Generated when there is a change of the received quality level on the Precision Timing Protocol (PTP).

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingRef1Alarm

Table 126. tmnxEqSyncIfTimingRef1Alarm properties

Property name

Value

Application name

CHASSIS

Event ID

2019

Event name

tmnxEqSyncIfTimingRef1Alarm

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.28

Default severity

minor

Message format string

Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on reference 1

Cause

Generated when an alarm condition on the first timing reference is detected. The type of alarm (los, oof, etc) is indicated in the details of the log event or alarm, and is also available in the tmnxSyncIfTimingNotifyAlarm attribute included in the SNMP notification. The SNMP notification will have the same indices as those of the tmnxCpmCardTable.

Effect

Indicated timing reference (1, 2, or BITS) cannot be used as a source of timing into the central clock.

Recovery

Address issues with the signal associated with indicated timing reference (1, 2, or BITS).

tmnxEqSyncIfTimingRef1AlarmClear

Table 127. tmnxEqSyncIfTimingRef1AlarmClear properties

Property name

Value

Application name

CHASSIS

Event ID

2020

Event name

tmnxEqSyncIfTimingRef1AlarmClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.29

Default severity

minor

Message format string

Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on reference 1 cleared

Cause

Generated when an alarm condition on the first timing reference is cleared. This notification will have the same indices as those of the tmnxCpmCardTable.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingRef1Quality

Table 128. tmnxEqSyncIfTimingRef1Quality properties

Property name

Value

Application name

CHASSIS

Event ID

2068

Event name

tmnxEqSyncIfTimingRef1Quality

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.56

Default severity

minor

Message format string

Synchronous Timing interface, reference 1 received quality level $tmnxSyncIfTimingRef1RxQltyLevel$

Cause

Generated when there is a change of the received quality level on timing reference 1.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingRef2Alarm

Table 129. tmnxEqSyncIfTimingRef2Alarm properties

Property name

Value

Application name

CHASSIS

Event ID

2021

Event name

tmnxEqSyncIfTimingRef2Alarm

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.30

Default severity

minor

Message format string

Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on reference 2

Cause

Generated when an alarm condition on the second timing reference is detected. This notification will have the same indices as those of the tmnxCpmCardTable.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingRef2AlarmClear

Table 130. tmnxEqSyncIfTimingRef2AlarmClear properties

Property name

Value

Application name

CHASSIS

Event ID

2022

Event name

tmnxEqSyncIfTimingRef2AlarmClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.31

Default severity

minor

Message format string

Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on reference 2 cleared

Cause

Generated when an alarm condition on the second timing reference is cleared. This notification will have the same indices as those of the tmnxCpmCardTable.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingRef2Quality

Table 131. tmnxEqSyncIfTimingRef2Quality properties

Property name

Value

Application name

CHASSIS

Event ID

2069

Event name

tmnxEqSyncIfTimingRef2Quality

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.57

Default severity

minor

Message format string

Synchronous Timing interface, reference 2 received quality level $tmnxSyncIfTimingRef2RxQltyLevel$

Cause

Generated when there is a change of the received quality level on timing reference 2.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingRefSwitch

Table 132. tmnxEqSyncIfTimingRefSwitch properties

Property name

Value

Application name

CHASSIS

Event ID

2072

Event name

tmnxEqSyncIfTimingRefSwitch

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.60

Default severity

minor

Message format string

Synchronous Timing interface, timing reference changed to $tmnxSyncIfTimingRef1InUse$

Cause

Generated when there is a change of which timing reference is providing timing for the system.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingSyncE2Alarm

Table 133. tmnxEqSyncIfTimingSyncE2Alarm properties

Property name

Value

Application name

CHASSIS

Event ID

2205

Event name

tmnxEqSyncIfTimingSyncE2Alarm

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.216

Default severity

minor

Message format string

Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on SYNCE2 reference

Cause

Generated when an alarm condition on the SYNCE 2 timing reference is detected. This notification will have the same indices as those of the tmnxCpmCardTable.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingSyncE2AlarmClr

Table 134. tmnxEqSyncIfTimingSyncE2AlarmClr properties

Property name

Value

Application name

CHASSIS

Event ID

2206

Event name

tmnxEqSyncIfTimingSyncE2AlarmClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.217

Default severity

minor

Message format string

Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on SYNCE2 reference cleared

Cause

Generated when an alarm condition on the SYNCE 2 timing reference is cleared. This notification will have the same indices as those of the tmnxCpmCardTable.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingSyncE2Quality

Table 135. tmnxEqSyncIfTimingSyncE2Quality properties

Property name

Value

Application name

CHASSIS

Event ID

2202

Event name

tmnxEqSyncIfTimingSyncE2Quality

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.213

Default severity

minor

Message format string

Synchronous Timing interface, reference SYNCE2 received quality level $tmnxSyncIfTimingSyncE2RxQltyLevl$

Cause

Generated when there is a change of the received quality level on timing reference synce2.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingSyncEAlarm

Table 136. tmnxEqSyncIfTimingSyncEAlarm properties

Property name

Value

Application name

CHASSIS

Event ID

2203

Event name

tmnxEqSyncIfTimingSyncEAlarm

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.214

Default severity

minor

Message format string

Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on SYNCE reference

Cause

Generated when an alarm condition on the SYNCE timing reference is detected. This notification will have the same indices as those of the tmnxCpmCardTable.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingSyncEAlarmClr

Table 137. tmnxEqSyncIfTimingSyncEAlarmClr properties

Property name

Value

Application name

CHASSIS

Event ID

2204

Event name

tmnxEqSyncIfTimingSyncEAlarmClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.215

Default severity

minor

Message format string

Synchronous Timing interface, alarm $tmnxSyncIfTimingNotifyAlarm$ on SYNCE reference cleared

Cause

Generated when an alarm condition on the SYNCE timing reference is cleared. This notification will have the same indices as those of the tmnxCpmCardTable.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingSyncEQuality

Table 138. tmnxEqSyncIfTimingSyncEQuality properties

Property name

Value

Application name

CHASSIS

Event ID

2201

Event name

tmnxEqSyncIfTimingSyncEQuality

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.212

Default severity

minor

Message format string

Synchronous Timing interface, reference SYNCE received quality level $tmnxSyncIfTimingSyncERxQltyLevel$

Cause

Generated when there is a change of the received quality level on timing reference synce.

Effect

N/A

Recovery

N/A

tmnxEqSyncIfTimingSystemQuality

Table 139. tmnxEqSyncIfTimingSystemQuality properties

Property name

Value

Application name

CHASSIS

Event ID

2077

Event name

tmnxEqSyncIfTimingSystemQuality

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.65

Default severity

minor

Message format string

Synchronous Timing interface, System Quality Level changed to $tmnxSyncIfTimingSystemQltyLevel$

Cause

This notification may be triggered for the following reasons: 1) There has been a switch in the timing reference in use by the network element, either because the previously active timing reference was disqualified, or to ensure that the network element is using the timing reference with the best timing quality. 2) There has been a change in the active timing reference's quality and the change does not result in a timing reference switch. 3) The network element has transitioned into or out of the holdover state.

Effect

The system quality level is used to determine the SSM code transmitted on synchronous interfaces. This may affect the SSM code transmitted on some or all interfaces, which may affect the distribution of timing throughout the network.

Recovery

If the customer is expecting the system to be locked to a reference of a particular quality and the system quality has decreased, the customer will need to determine the root cause (for example, loss of communication with a satellite) and resolve the issue.

tmnxEqWrongCard

Table 140. tmnxEqWrongCard properties

Property name

Value

Application name

CHASSIS

Event ID

2004

Event name

tmnxEqWrongCard

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.10

Default severity

minor

Message format string

Class $tmnxHwClass$ : wrong type inserted

Cause

Generated when the wrong type of card is inserted into a slot of the chassis. Even though a card may be physically supported by the slot, it may have been administratively configured to allow only certain card types in a particular slot location. The card type may be IOM (or XCM), Fabric, MDA (or XMA), MCM, CPM module, etc.

Effect

The effect is dependent on the card that has been incorrectly inserted. Incorrect IOM (or XCM) or MDA (or XMA) insertion will cause a loss of service for all services running on that card.

Recovery

Insert the correct card into the correct slot, and ensure the slot is configured for the correct type of card.

tmnxEsaCleared

Table 141. tmnxEsaCleared properties

Property name

Value

Application name

CHASSIS

Event ID

2213

Event name

tmnxEsaCleared

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.224

Default severity

major

Message format string

ESA $tmnxEsaNotifyId$ cleared

Cause

The tmnxEsaCleared notification is generated when an ESA is cleared or rebooted.

Effect

N/A

Recovery

N/A

tmnxEsaConnected

Table 142. tmnxEsaConnected properties

Property name

Value

Application name

CHASSIS

Event ID

2210

Event name

tmnxEsaConnected

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.221

Default severity

minor

Message format string

ESA $tmnxEsaNotifyId$ connected

Cause

The tmnxEsaConnected notification is generated when a new ESA is connected.

Effect

N/A

Recovery

N/A

tmnxEsaDisconnected

Table 143. tmnxEsaDisconnected properties

Property name

Value

Application name

CHASSIS

Event ID

2211

Event name

tmnxEsaDisconnected

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.222

Default severity

major

Message format string

ESA $tmnxEsaNotifyId$ disconnected

Cause

The tmnxEsaDisconnected notification is generated when an ESA is disconnected.

Effect

N/A

Recovery

N/A

tmnxEsaDiscovered

Table 144. tmnxEsaDiscovered properties

Property name

Value

Application name

CHASSIS

Event ID

2209

Event name

tmnxEsaDiscovered

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.220

Default severity

minor

Message format string

ESA $tmnxEsaNotifyId$ discovered

Cause

The tmnxEsaDiscovered notification is generated when a new ESA is discovered by the system.

Effect

N/A

Recovery

N/A

tmnxEsaFailure

Table 145. tmnxEsaFailure properties

Property name

Value

Application name

CHASSIS

Event ID

2212

Event name

tmnxEsaFailure

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.223

Default severity

major

Message format string

ESA $tmnxEsaNotifyId$ failed with reason $tmnxEsaStatsOperFlags$

Cause

The tmnxEsaFailure notification is generated when a failure occurs on an ESA.

Effect

N/A

Recovery

N/A

tmnxEsaFirmwareUpgradeStarted

Table 146. tmnxEsaFirmwareUpgradeStarted properties

Property name

Value

Application name

CHASSIS

Event ID

2230

Event name

tmnxEsaFirmwareUpgradeStarted

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.241

Default severity

minor

Message format string

ESA $tmnxEsaNotifyId$ Firmware upgrade started

Cause

The tmnxEsaFirmwareUpgradeStarted notification is generated when an ESA requests a firmware upgrade and is in progress.

Effect

N/A

Recovery

N/A

tmnxEsaHwFanBankFailRedun

Table 147. tmnxEsaHwFanBankFailRedun properties

Property name

Value

Application name

CHASSIS

Event ID

2414

Event name

tmnxEsaHwFanBankFailRedun

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.279

Default severity

critical

Message format string

ESA $tmnxHwClass$ fan bank status failed-redundant

Cause

The tmnxEsaHwFanBankFailRedun notification is generated when one or more ESA fans fail, compromising the fan bank redundancy.

Effect

ESA cooling may be inadequate if fan failure occurs.

Recovery

Contact Nokia customer support.

tmnxEsaHwFanBankFailRedunClr

Table 148. tmnxEsaHwFanBankFailRedunClr properties

Property name

Value

Application name

CHASSIS

Event ID

2415

Event name

tmnxEsaHwFanBankFailRedunClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.280

Default severity

cleared

Message format string

ESA $tmnxHwClass$ fan bank failed-redundant status cleared, now $tmnxEsaStatsFanRedundancy$

Cause

The tmnxEsaHwFanBankFailRedunClr notification is generated when all ESA fans recover, restoring the fan bank redundancy.

Effect

N/A

Recovery

N/A

tmnxEsaHwFanBankNonRedun

Table 149. tmnxEsaHwFanBankNonRedun properties

Property name

Value

Application name

CHASSIS

Event ID

2412

Event name

tmnxEsaHwFanBankNonRedun

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.277

Default severity

major

Message format string

ESA $tmnxHwClass$ fan bank status non-redundant

Cause

The tmnxEsaHwFanBankNonRedun notification is generated when a condition compromises the ESA fan bank redundancy.

Effect

ESA cooling may be inadequate if fan failure occurs.

Recovery

Contact Nokia customer support.

tmnxEsaHwFanBankNonRedunClr

Table 150. tmnxEsaHwFanBankNonRedunClr properties

Property name

Value

Application name

CHASSIS

Event ID

2413

Event name

tmnxEsaHwFanBankNonRedunClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.278

Default severity

cleared

Message format string

ESA $tmnxHwClass$ fan bank non-redundant status cleared, now $tmnxEsaStatsFanRedundancy$

Cause

The tmnxEsaHwFanBankNonRedunClr notification is generated when the ESA fan bank redundancy is restored.

Effect

N/A

Recovery

N/A

tmnxEsaHwFanStatusDegraded

Table 151. tmnxEsaHwFanStatusDegraded properties

Property name

Value

Application name

CHASSIS

Event ID

2416

Event name

tmnxEsaHwFanStatusDegraded

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.281

Default severity

critical

Message format string

ESA $tmnxHwClass$ fan status degraded

Cause

The tmnxEsaHwFanStatusDegraded notification is generated when one or more ESA fans are degraded.

Effect

ESA cooling may be inadequate.

Recovery

Contact Nokia customer support.

tmnxEsaHwFanStatusDegradedClr

Table 152. tmnxEsaHwFanStatusDegradedClr properties

Property name

Value

Application name

CHASSIS

Event ID

2417

Event name

tmnxEsaHwFanStatusDegradedClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.282

Default severity

cleared

Message format string

ESA $tmnxHwClass$ fan degraded status cleared, now $tmnxEsaStatsFanStatus$

Cause

The tmnxEsaHwFanStatusDegradedClr notification is generated when ESA fans are no longer degraded.

Effect

N/A

Recovery

N/A

tmnxEsaHwFanStatusFailed

Table 153. tmnxEsaHwFanStatusFailed properties

Property name

Value

Application name

CHASSIS

Event ID

2418

Event name

tmnxEsaHwFanStatusFailed

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.283

Default severity

critical

Message format string

ESA $tmnxHwClass$ fan status failed

Cause

The tmnxEsaHwFanStatusFailed notification is generated when one or more ESA fans fail.

Effect

ESA cooling may be inadequate.

Recovery

Contact Nokia customer support.

tmnxEsaHwFanStatusFailedClr

Table 154. tmnxEsaHwFanStatusFailedClr properties

Property name

Value

Application name

CHASSIS

Event ID

2419

Event name

tmnxEsaHwFanStatusFailedClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.284

Default severity

cleared

Message format string

ESA $tmnxHwClass$ fan failed status cleared, now $tmnxEsaStatsFanStatus$

Cause

The tmnxEsaHwFanStatusFailedClr notification is generated when the ESA fans are restored.

Effect

N/A

Recovery

N/A

tmnxEsaHwPwrSup1Degraded

Table 155. tmnxEsaHwPwrSup1Degraded properties

Property name

Value

Application name

CHASSIS

Event ID

2404

Event name

tmnxEsaHwPwrSup1Degraded

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.269

Default severity

critical

Message format string

ESA $tmnxHwClass$ power supply 1 status degraded

Cause

The tmnxEsaHwPwrSup1Degraded notification is generated when the ESA power supply 1 is degraded.

Effect

Power supply operation and reliability may be affected.

Recovery

Contact Nokia customer support.

tmnxEsaHwPwrSup1DegradedClr

Table 156. tmnxEsaHwPwrSup1DegradedClr properties

Property name

Value

Application name

CHASSIS

Event ID

2405

Event name

tmnxEsaHwPwrSup1DegradedClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.270

Default severity

cleared

Message format string

ESA $tmnxHwClass$ power supply 1 degraded status cleared, now $tmnxEsaStatsPowerSupply1Status$

Cause

The tmnxEsaHwPwrSup1DegradedClr notification is generated when the ESA power supply 1 is no longer degraded.

Effect

N/A

Recovery

N/A

tmnxEsaHwPwrSup1Failed

Table 157. tmnxEsaHwPwrSup1Failed properties

Property name

Value

Application name

CHASSIS

Event ID

2406

Event name

tmnxEsaHwPwrSup1Failed

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.271

Default severity

critical

Message format string

ESA $tmnxHwClass$ power supply 1 status failed

Cause

The tmnxEsaHwPwrSup1Failed notification is generated when the ESA power supply 1 fails.

Effect

Power supply and redundancy are affected. ESA operation may be affected.

Recovery

Contact Nokia customer support.

tmnxEsaHwPwrSup1FailedClr

Table 158. tmnxEsaHwPwrSup1FailedClr properties

Property name

Value

Application name

CHASSIS

Event ID

2407

Event name

tmnxEsaHwPwrSup1FailedClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.272

Default severity

cleared

Message format string

ESA $tmnxHwClass$ power supply 1 failed status cleared, now $tmnxEsaStatsPowerSupply1Status$

Cause

The tmnxEsaHwPwrSup1FailedClr notification is generated when the ESA power supply 1 is restored.

Effect

N/A

Recovery

N/A

tmnxEsaHwPwrSup2Degraded

Table 159. tmnxEsaHwPwrSup2Degraded properties

Property name

Value

Application name

CHASSIS

Event ID

2408

Event name

tmnxEsaHwPwrSup2Degraded

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.273

Default severity

critical

Message format string

ESA $tmnxHwClass$ power supply 2 status degraded

Cause

The tmnxEsaHwPwrSup2Degraded notification is generated when the ESA power supply 2 is degraded.

Effect

Power supply operation and reliability may be affected.

Recovery

Contact Nokia customer support.

tmnxEsaHwPwrSup2DegradedClr

Table 160. tmnxEsaHwPwrSup2DegradedClr properties

Property name

Value

Application name

CHASSIS

Event ID

2409

Event name

tmnxEsaHwPwrSup2DegradedClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.274

Default severity

cleared

Message format string

ESA $tmnxHwClass$ power supply 2 degraded status cleared, now $tmnxEsaStatsPowerSupply2Status$

Cause

The tmnxEsaHwPwrSup2DegradedClr notification is generated when the ESA power supply 2 is no longer degraded.

Effect

N/A

Recovery

N/A

tmnxEsaHwPwrSup2Failed

Table 161. tmnxEsaHwPwrSup2Failed properties

Property name

Value

Application name

CHASSIS

Event ID

2410

Event name

tmnxEsaHwPwrSup2Failed

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.275

Default severity

critical

Message format string

ESA $tmnxHwClass$ power supply 2 status failed

Cause

The tmnxEsaHwPwrSup2Failed notification is generated when the ESA power supply 2 fails.

Effect

Power supply and redundancy are affected. ESA operation may be affected.

Recovery

Contact Nokia customer support.

tmnxEsaHwPwrSup2FailedClr

Table 162. tmnxEsaHwPwrSup2FailedClr properties

Property name

Value

Application name

CHASSIS

Event ID

2411

Event name

tmnxEsaHwPwrSup2FailedClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.276

Default severity

cleared

Message format string

ESA $tmnxHwClass$ power supply 2 failed status cleared, now $tmnxEsaStatsPowerSupply2Status$

Cause

The tmnxEsaHwPwrSup2FailedClr notification is generated when the ESA power supply 2 is restored.

Effect

N/A

Recovery

N/A

tmnxEsaHwPwrSupBankFailRedun

Table 163. tmnxEsaHwPwrSupBankFailRedun properties

Property name

Value

Application name

CHASSIS

Event ID

2424

Event name

tmnxEsaHwPwrSupBankFailRedun

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.289

Default severity

critical

Message format string

ESA $tmnxHwClass$ power supply bank status failed-redundant

Cause

The tmnxEsaHwPwrSupBankFailRedun notification is generated when the ESA power supply redundancy fails.

Effect

ESA operation may be affected if additional power supply failures occur.

Recovery

Contact Nokia customer support.

tmnxEsaHwPwrSupBankFailRedunClr

Table 164. tmnxEsaHwPwrSupBankFailRedunClr properties

Property name

Value

Application name

CHASSIS

Event ID

2425

Event name

tmnxEsaHwPwrSupBankFailRedunClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.290

Default severity

cleared

Message format string

ESA $tmnxHwClass$ power supply bank failed-redundant status cleared, now $tmnxEsaStatsPwrSupRedundancy$

Cause

The tmnxEsaHwPwrSupBankFailRedunClr notification is generated when the ESA power supplies regain redundancy.

Effect

N/A

Recovery

N/A

tmnxEsaHwPwrSupBankNonRedun

Table 165. tmnxEsaHwPwrSupBankNonRedun properties

Property name

Value

Application name

CHASSIS

Event ID

2422

Event name

tmnxEsaHwPwrSupBankNonRedun

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.287

Default severity

major

Message format string

ESA $tmnxHwClass$ power supply bank status non-redundant

Cause

The tmnxEsaHwPwrSupBankNonRedun notification is generated when the ESA power supply redundancy is degraded.

Effect

ESA may lose power supply redundancy if power supply failures occur.

Recovery

Contact Nokia customer support.

tmnxEsaHwPwrSupBankNonRedunClr

Table 166. tmnxEsaHwPwrSupBankNonRedunClr properties

Property name

Value

Application name

CHASSIS

Event ID

2423

Event name

tmnxEsaHwPwrSupBankNonRedunClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.288

Default severity

cleared

Message format string

ESA $tmnxHwClass$ power supply bank non-redundant status cleared, now $tmnxEsaStatsPwrSupRedundancy$

Cause

The tmnxEsaHwPwrSupBankNonRedunClr notification is generated when the ESA power supplies return to a fully redundant state.

Effect

N/A

Recovery

N/A

tmnxEsaHwPwrSupMismatch

Table 167. tmnxEsaHwPwrSupMismatch properties

Property name

Value

Application name

CHASSIS

Event ID

2420

Event name

tmnxEsaHwPwrSupMismatch

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.285

Default severity

major

Message format string

ESA $tmnxHwClass$ power supply mismatch

Cause

The tmnxEsaHwPwrSupMismatch notification is generated when the ESA power supplies do not match.

Effect

ESA power supplies must be matched.

Recovery

Equip the ESA with matching power supplies.

tmnxEsaHwPwrSupMismatchClr

Table 168. tmnxEsaHwPwrSupMismatchClr properties

Property name

Value

Application name

CHASSIS

Event ID

2421

Event name

tmnxEsaHwPwrSupMismatchClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.286

Default severity

cleared

Message format string

ESA $tmnxHwClass$ power supply mismatch - cleared, now $tmnxEsaStatsPwrSupMismatchStatus$

Cause

The tmnxEsaHwPwrSupMismatchClr notification is generated when the ESA power supplies are no longer mismatched.

Effect

N/A

Recovery

N/A

tmnxEsaHwStatusCritical

Table 169. tmnxEsaHwStatusCritical properties

Property name

Value

Application name

CHASSIS

Event ID

2402

Event name

tmnxEsaHwStatusCritical

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.267

Default severity

critical

Message format string

ESA $tmnxHwClass$ aggregate hardware status critical

Cause

The tmnxEsaHwStatusCritical notification is generated when the ESA hardware status is critical.

Effect

Service may be affected.

Recovery

Contact Nokia customer support.

tmnxEsaHwStatusCriticalClr

Table 170. tmnxEsaHwStatusCriticalClr properties

Property name

Value

Application name

CHASSIS

Event ID

2403

Event name

tmnxEsaHwStatusCriticalClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.268

Default severity

cleared

Message format string

ESA $tmnxHwClass$ aggregate hardware status critical - cleared, now $tmnxEsaStatsHardwareStatus$

Cause

The tmnxEsaHwStatusCriticalClr notification is generated when the ESA hardware status is no longer critical.

Effect

N/A

Recovery

N/A

tmnxEsaHwStatusDegraded

Table 171. tmnxEsaHwStatusDegraded properties

Property name

Value

Application name

CHASSIS

Event ID

2400

Event name

tmnxEsaHwStatusDegraded

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.265

Default severity

major

Message format string

ESA $tmnxHwClass$ aggregate hardware status degraded

Cause

The tmnxEsaHwStatusDegraded notification is generated when one or more ESA hardware components are degraded.

Effect

Service may be affected.

Recovery

Contact Nokia customer support.

tmnxEsaHwStatusDegradedClr

Table 172. tmnxEsaHwStatusDegradedClr properties

Property name

Value

Application name

CHASSIS

Event ID

2401

Event name

tmnxEsaHwStatusDegradedClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.266

Default severity

cleared

Message format string

ESA $tmnxHwClass$ aggregate hardware degraded status cleared, now $tmnxEsaStatsHardwareStatus$

Cause

The tmnxEsaHwStatusDegradedClr notification is generated when ESA hardware components are no longer degraded.

Effect

N/A

Recovery

N/A

tmnxEsaHwTemperatureDegraded

Table 173. tmnxEsaHwTemperatureDegraded properties

Property name

Value

Application name

CHASSIS

Event ID

2426

Event name

tmnxEsaHwTemperatureDegraded

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.291

Default severity

critical

Message format string

ESA $tmnxHwClass$ temperature status degraded

Cause

The tmnxEsaHwTemperatureDegraded notification is generated when the ESA temperature is outside the expected operating range.

Effect

If the ESA temperature remains outside the expected operating range, the ESA may shut down.

Recovery

The ESA may need manual maintenance to rectify the issue. Contact Nokia customer support.

tmnxEsaHwTemperatureDegradedClr

Table 174. tmnxEsaHwTemperatureDegradedClr properties

Property name

Value

Application name

CHASSIS

Event ID

2427

Event name

tmnxEsaHwTemperatureDegradedClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.292

Default severity

cleared

Message format string

ESA $tmnxHwClass$ temperature degraded status cleared, now $tmnxEsaStatsTemperatureStatus$

Cause

The tmnxEsaHwTemperatureDegradedClr notification is generated when the ESA returns to a temperature within the expected operating range.

Effect

N/A

Recovery

N/A

tmnxEsaHwTemperatureFailed

Table 175. tmnxEsaHwTemperatureFailed properties

Property name

Value

Application name

CHASSIS

Event ID

2428

Event name

tmnxEsaHwTemperatureFailed

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.293

Default severity

critical

Message format string

ESA $tmnxHwClass$ temperature status failed

Cause

The tmnxEsaHwTemperatureFailed notification is generated when the ESA temperature is critical.

Effect

If the ESA temperature remains outside the expected operating range, the ESA may shut down.

Recovery

The ESA may need manual maintenance to rectify the issue. Contact Nokia customer support.

tmnxEsaHwTemperatureFailedClr

Table 176. tmnxEsaHwTemperatureFailedClr properties

Property name

Value

Application name

CHASSIS

Event ID

2429

Event name

tmnxEsaHwTemperatureFailedClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.294

Default severity

cleared

Message format string

ESA $tmnxHwClass$ temperature failed status cleared, now $tmnxEsaStatsTemperatureStatus$

Cause

The tmnxEsaHwTemperatureFailedClr notification is generated when the ESA returns to a temperature within the expected operating range.

Effect

N/A

Recovery

N/A

tmnxEsaVmBooted

Table 177. tmnxEsaVmBooted properties

Property name

Value

Application name

CHASSIS

Event ID

2215

Event name

tmnxEsaVmBooted

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.226

Default severity

major

Message format string

ESA-VM $tmnxEsaNotifyId$/ $tmnxEsaVmNotifyId$ booted

Cause

The tmnxEsaVmBooted notification is generated when an ESA VM is booted.

Effect

N/A

Recovery

N/A

tmnxEsaVmCleared

Table 178. tmnxEsaVmCleared properties

Property name

Value

Application name

CHASSIS

Event ID

2217

Event name

tmnxEsaVmCleared

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.228

Default severity

minor

Message format string

ESA-VM $tmnxEsaNotifyId$/ $tmnxEsaVmNotifyId$ reset

Cause

The tmnxEsaVmCleared notification is generated when an ESA VM is cleared or restarted.

Effect

N/A

Recovery

N/A

tmnxEsaVmCreated

Table 179. tmnxEsaVmCreated properties

Property name

Value

Application name

CHASSIS

Event ID

2214

Event name

tmnxEsaVmCreated

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.225

Default severity

major

Message format string

ESA-VM $tmnxEsaNotifyId$/ $tmnxEsaVmNotifyId$ created

Cause

The tmnxEsaVmCreated notification is generated when an ESA VM is created.

Effect

N/A

Recovery

N/A

tmnxEsaVmFailure

Table 180. tmnxEsaVmFailure properties

Property name

Value

Application name

CHASSIS

Event ID

2218

Event name

tmnxEsaVmFailure

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.229

Default severity

major

Message format string

ESA-VM $tmnxEsaNotifyId$/ $tmnxEsaVmNotifyId$ failed with reason $tmnxEsaVmStatsOperFlags$

Cause

The tmnxEsaVmFailure notification is generated when an ESA VM crashes.

Effect

N/A

Recovery

N/A

tmnxEsaVmRemoved

Table 181. tmnxEsaVmRemoved properties

Property name

Value

Application name

CHASSIS

Event ID

2216

Event name

tmnxEsaVmRemoved

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.227

Default severity

major

Message format string

ESA-VM $tmnxEsaNotifyId$/ $tmnxEsaVmNotifyId$ destroyed

Cause

The tmnxEsaVmRemoved notification is generated when an ESA VM is removed.

Effect

N/A

Recovery

N/A

tmnxExtStandbyCpmReboot

Table 182. tmnxExtStandbyCpmReboot properties

Property name

Value

Application name

CHASSIS

Event ID

2127

Event name

tmnxExtStandbyCpmReboot

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.114

Default severity

warning

Message format string

Rebooting extension standby CPM due to master standby CPM reboot and transition into or out of an ISSU state.

Cause

The tmnxExtStandbyCpmReboot notification is generated after a master standby CPM reboots and it is determined that the master standby CPM has transitioned into or out of an ISSU state. This detected transition will cause a reboot of the extension standby CPM (this reboot is necessary and expected for ISSU operation). This notification helps an operator understand why an extension standby CPM may have rebooted.

Effect

The extension standby CPM will reboot.

Recovery

There is no recovery for this notification.

tmnxExtStandbyCpmRebootFail

Table 183. tmnxExtStandbyCpmRebootFail properties

Property name

Value

Application name

CHASSIS

Event ID

2128

Event name

tmnxExtStandbyCpmRebootFail

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.115

Default severity

minor

Message format string

Unable to automatically reboot extension standby CPM during ISSU.

Cause

The tmnxExtStandbyCpmRebootFail notification is generated after a master standby CPM reboots and it is determined that the master standby CPM has transitioned into or out of an ISSU state. The system will attempt to reboot the extension standby CPM as part of the normal ISSU process. If the system determines that it cannot reboot the extension standby CPM (i.e. it is not reachable) then this log event is raised.

Effect

The extension standby CPM may not transition to the ISSU state in which case the ISSU cannot proceed normally.

Recovery

Resetting the extension standby CPM can be attempted to try and get the CPM into an ISSU state. If that is not successful, then the ISSU should be aborted.

tmnxFPResourcePolicyModified

Table 184. tmnxFPResourcePolicyModified properties

Property name

Value

Application name

CHASSIS

Event ID

2222

Event name

tmnxFPResourcePolicyModified

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.233

Default severity

minor

Message format string

Class $tmnxHwClass$ : Card : FP resource policy changed, the configuration must be saved and the system rebooted immediately

Cause

The FP resource policy applied to the FP has been modified, or a different FP resource policy is applied to the FP.

Effect

Modifying the configuration could result in a failure to instantiate queues.

Recovery

The configuration must be saved and the system rebooted immediately.

tmnxFPResourcePolicyModifiedClr

Table 185. tmnxFPResourcePolicyModifiedClr properties

Property name

Value

Application name

CHASSIS

Event ID

2223

Event name

tmnxFPResourcePolicyModifiedClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.234

Default severity

minor

Message format string

Class $tmnxHwClass$ : Card : alarm $tmnxFPResourcePolicyModified$ cleared

Cause

Generates a notification when tmnxFPResourcePolicyModified is cleared.

Effect

None.

Recovery

None.

tmnxFPResOversubscribed

Table 186. tmnxFPResOversubscribed properties

Property name

Value

Application name

CHASSIS

Event ID

2246

Event name

tmnxFPResOversubscribed

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.263

Default severity

major

Message format string

Card $tmnxCardSlotNum$ FP $tmnxFPNum$ resources oversubscribed: $tFPResOversub$

Cause

The tmnxFPResOversubscribed notification is generated when one or more of the FP resources have been oversubscribed.

Effect

Usage beyond limits can result in the system dropping packets which may cause degradation in service quality.

Recovery

Reduce traffic load and/or conjestion on the system. More specific action might be required depending on the specific oversubscription.

tmnxFPResOversubscribedCleared

Table 187. tmnxFPResOversubscribedCleared properties

Property name

Value

Application name

CHASSIS

Event ID

2247

Event name

tmnxFPResOversubscribedCleared

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.264

Default severity

cleared

Message format string

Card $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFabricSlotNum$ resources no longer oversubscribed

Cause

The tmnxFPResOversubscribedCleared notification is generated when none of the FP resources are oversubscribed.

Effect

The system returns to normal mode of operation and can service all the received traffic in the configured manner.

Recovery

There is no recovery for this notification.

tmnxGnssAcquiredFix

Table 188. tmnxGnssAcquiredFix properties

Property name

Value

Application name

CHASSIS

Event ID

2189

Event name

tmnxGnssAcquiredFix

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.180

Default severity

minor

Message format string

GNSS Receiver - position fix obtained

Cause

The tmnxGnssAcquiredFix notification is generated when the GNSS receiver has acquired a valid fix on its position.

Effect

The position of the system is known.

Recovery

None needed

tmnxGnssAcquiringFix

Table 189. tmnxGnssAcquiringFix properties

Property name

Value

Application name

CHASSIS

Event ID

2188

Event name

tmnxGnssAcquiringFix

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.179

Default severity

minor

Message format string

GNSS Receiver - attempting to acquire a position fix

Cause

The tmnxGnssAcquiringFix notification is generated when the GNSS receiver starts to acquire a fix. This occurs when the GNSS receiver is enabled, and also when the GNSS receiver loses its fix.

Effect

The position of the system is unknown until the receiver acquires a fix.

Recovery

Ensure that the GNSS antenna is properly connected to the system.

tmnxHwAggShpSchedEventOvrflw

Table 190. tmnxHwAggShpSchedEventOvrflw properties

Property name

Value

Application name

CHASSIS

Event ID

2243

Event name

tmnxHwAggShpSchedEventOvrflw

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.260

Default severity

minor

Message format string

Hw Agg Shaped Sched log event overflow occurred on card $tmnxChassisNotifyCardSlotNum$ at $tmnxHwAggShpTimeEventOccured$

Cause

The tmnxHwAggShpSchedEventOvrflwClr notification is generated when HW Agg Shaper Scheduler oper color occurs more than 200 times because of Number of agg-shapers parented to a scheduler. The IOM raises the final trap to indicate overflow and stops logging traps.

Effect

Hw Agg shaper scheduler color notifications on the card may not be received.

Recovery

Notifications will resume once the Overflow clear is set.

tmnxHwAggShpSchedEventOvrflwClr

Table 191. tmnxHwAggShpSchedEventOvrflwClr properties

Property name

Value

Application name

CHASSIS

Event ID

2242

Event name

tmnxHwAggShpSchedEventOvrflwClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.259

Default severity

minor

Message format string

$tmnxHwAggShpMissingNotifCount$ HW Agg Shaper Sched events were dropped in the last event throttling interval on card $tmnxChassisNotifyCardSlotNum$ at $tmnxHwAggShpTimeEventOccured$

Cause

The tmnxHwAggShpSchedEventOvrflwClr notification is generated when the CPM polls the IOM for Hw Agg Shaper Sched traps and the overflow is cleared by logging an overflow-clear on a particular card.

Effect

Notifications are received again since the event throttling has ended.

Recovery

There is no recovery for this notification.

tmnxInterChassisCommsDown

Table 192. tmnxInterChassisCommsDown properties

Property name

Value

Application name

CHASSIS

Event ID

4001

Event name

tmnxInterChassisCommsDown

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxInterChassisNotifications.1

Default severity

critical

Message format string

Control communications disrupted between the active CPM and the chassis

Cause

The tmnxInterChassisCommsDown alarm is generated when the active CPM cannot reach the far-end chassis.

Effect

The resources on the far-end chassis are not available. This event for the far-end chassis means that the CPM, SFM, and XCM cards in the far-end chassis will reboot and remain operationally down until communications are re-established.

Recovery

Ensure that all CPM interconnect ports in the system are properly cabled together with working cables.

tmnxInterChassisCommsUp

Table 193. tmnxInterChassisCommsUp properties

Property name

Value

Application name

CHASSIS

Event ID

4002

Event name

tmnxInterChassisCommsUp

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxInterChassisNotifications.2

Default severity

critical

Message format string

Control communications established between the active CPM and the chassis

Cause

The tmnxInterChassisCommsUp notification is generated when the control communications are re-established between the active CPM and the far-end chassis.

Effect

The resources on the far-end chassis are now available. This event for the far-end chassis means that the CPM, SFM and XCM cards in the far-end chassis will start the process of coming back into service.

Recovery

N/A

tmnxIomEventOverflow

Table 194. tmnxIomEventOverflow properties

Property name

Value

Application name

CHASSIS

Event ID

2124

Event name

tmnxIomEventOverflow

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.111

Default severity

minor

Message format string

Iom $tmnxIomResourceType$ Resource event overflow occurred on card $tmnxChassisNotifyCardSlotNum$ at $tmnxIomResLimitTimeEventOccured$.

Cause

The tmnxIomEventOverflow notification is generated when tmnxIomResStateClr, tmnxIomResExhausted and tmnxIomResHighLimitReached occur more than 200 times because of resource usage fluctuation. The IOM raises the final trap to indicate overflow and stops logging traps.

Effect

Some FP notifications configured on the card may not be received.

Recovery

Notifications will resume once the Overflow clear is set.

tmnxIomEventOverflowClr

Table 195. tmnxIomEventOverflowClr properties

Property name

Value

Application name

CHASSIS

Event ID

2125

Event name

tmnxIomEventOverflowClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.112

Default severity

minor

Message format string

$tmnxIomResLimMissingNotifCount$ Iom $tmnxIomResourceType$ Resources events were dropped in the last event throttling interval on card $tmnxChassisNotifyCardSlotNum$ at $tmnxIomResLimitTimeEventOccured$.

Cause

The tmnxIomEventOverflowClr notification is generated when the CPM polls the IOM for traps and the overflow is cleared by logging an overflow-clear on a particular card.

Effect

Notifications are received again since the event throttling has ended.

Recovery

There is no recovery for this notification.

tmnxIomResExhausted

Table 196. tmnxIomResExhausted properties

Property name

Value

Application name

CHASSIS

Event ID

2122

Event name

tmnxIomResExhausted

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.109

Default severity

critical

Message format string

The $tmnxIomResourceType$ resources on IOM $tmnxChassisNotifyCardSlotNum$ and Forwarding Plane $tmnxChassisNotifyFpNum$ has been exhausted at $tmnxIomResLimitTimeEventOccured$.

Cause

The tmnxIomResExhausted notification is generated when the type of resources on IOM as specified by tmnxIomResourceType has reached the 100% of its utilization threshold.

Effect

The specified resource has reached the stats pool limit.

Recovery

Intervention may be required to recover resources.

tmnxIomResHighLimitReached

Table 197. tmnxIomResHighLimitReached properties

Property name

Value

Application name

CHASSIS

Event ID

2121

Event name

tmnxIomResHighLimitReached

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.108

Default severity

major

Message format string

The $tmnxIomResourceType$ resources on IOM $tmnxChassisNotifyCardSlotNum$ and Forwarding Plane $tmnxChassisNotifyFpNum$ has reached the $tmnxIomResourceLimitPct$% utilization threshold at $tmnxIomResLimitTimeEventOccured$.

Cause

The tmnxIomResHighLimitReached notification is generated when the resource (of type tmnxIomResourceType) utilization on IOM has reached the value of tmnxIomResourceLimitPct.

Effect

The specified resource limit is cleared when the number of in-use stats resources falls below the clear threshold of the stats pool limit.

Recovery

There is no recovery required for this notification.

tmnxIomResStateClr

Table 198. tmnxIomResStateClr properties

Property name

Value

Application name

CHASSIS

Event ID

2123

Event name

tmnxIomResStateClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.110

Default severity

minor

Message format string

The $tmnxIomResourceType$ resources on IOM $tmnxChassisNotifyCardSlotNum$ and Forwarding Plane $tmnxChassisNotifyFpNum$ has dropped below the $tmnxIomResourceLimitPct$% utilization threshold at $tmnxIomResLimitTimeEventOccured$.

Cause

The tmnxIomResStateClr notification is generated when the type of resources on IOM as specified by tmnxIomResourceType has dropped back down below the value of tmnxIomResourceLimitPct.

Effect

The specified resource limit is cleared when the number of in-use stats resources falls below tmnxIomResourceLimitPct of the stats pool limit.

Recovery

There is no recovery required for this notification.

tmnxIomRsrcEventOverflow

Table 199. tmnxIomRsrcEventOverflow properties

Property name

Value

Application name

CHASSIS

Event ID

3257

Event name

tmnxIomRsrcEventOverflow

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.257

Default severity

warning

Message format string

A resource event overflow occurred on card $tmnxChassisNotifyCardSlotNum$ at $tmnxIomRsrcTimeEventOccured$.

Cause

The tmnxIomRsrcEventOverflow notification is generated when tmnxIomRsrcUsageHighLimitReached, tmnxIomRsrcUsageExhausted, tmnxIomRsrcUsageRecovered, tmnxIomRsrcOwnerOversubscribed, or tmnxIomRsrcOwnerOversubscrbdClr occur more than 200 times because of resource usage fluctuation. The IOM raises the final trap to indicate overflow and stops logging traps.

Effect

Some IOM notifications may not be received.

Recovery

Notifications will resume once the Overflow clear is set.

tmnxIomRsrcEventOverflowClr

Table 200. tmnxIomRsrcEventOverflowClr properties

Property name

Value

Application name

CHASSIS

Event ID

3258

Event name

tmnxIomRsrcEventOverflowClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.258

Default severity

minor

Message format string

$tmnxIomRsrcMissingNotifCount$ resource events were dropped in the last event throttling interval on card $tmnxChassisNotifyCardSlotNum$ at $tmnxIomRsrcTimeEventOccured$.

Cause

The tmnxIomRsrcEventOverflowClr notification is generated when the CPM polls the IOM for traps and the overflow is cleared by logging an overflow-clear on a particular card.

Effect

Notifications are received again since the event throttling has ended.

Recovery

There is no recovery for this notification.

tmnxIomRsrcOwnerOversubscrbdClr

Table 201. tmnxIomRsrcOwnerOversubscrbdClr properties

Property name

Value

Application name

CHASSIS

Event ID

3260

Event name

tmnxIomRsrcOwnerOversubscrbdClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.262

Default severity

minor

Message format string

The $tmnxIomRsrcResourceType$ resources needed by $tmnxIomRsrcOwnerType$ on card $tmnxChassisNotifyCardSlotNum$ have been satisfied at $tmnxIomRsrcTimeEventOccured$. All $tmnxIomRsrcOwnerType$ traffic can flow.

Cause

The tmnxIomRsrcOwnerOversubscrbdClr notification is generated when all the required IOM resources of type tmnxIomRsrcResourceType for owner tmnxIomRsrcOwnerType have been allocated.

Effect

Traffic for owner tmnxIomRsrcOwnerType is no longer affected.

Recovery

There is no recovery for this notification.

tmnxIomRsrcOwnerOversubscribed

Table 202. tmnxIomRsrcOwnerOversubscribed properties

Property name

Value

Application name

CHASSIS

Event ID

3259

Event name

tmnxIomRsrcOwnerOversubscribed

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.261

Default severity

major

Message format string

The $tmnxIomRsrcResourceType$ resources needed by $tmnxIomRsrcOwnerType$ on card $tmnxChassisNotifyCardSlotNum$ are oversubscribed at $tmnxIomRsrcTimeEventOccured$. Some $tmnxIomRsrcOwnerType$ traffic may not flow.

Cause

The tmnxIomRsrcOwnerOversubscribed notification is generated when the IOM resource of type tmnxIomRsrcResourceType has been exhausted for owner tmnxIomRsrcOwnerType.

Effect

Traffic for owner tmnxIomRsrcOwnerType may be affected.

Recovery

Intervention may be required to recover resources.

tmnxIomRsrcUsageExhausted

Table 203. tmnxIomRsrcUsageExhausted properties

Property name

Value

Application name

CHASSIS

Event ID

3253

Event name

tmnxIomRsrcUsageExhausted

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.253

Default severity

critical

Message format string

Possible messages:

  • The $tmnxIomRsrcResourceType$ resources on card $tmnxChassisNotifyCardSlotNum$ have been exhausted at $tmnxIomRsrcTimeEventOccured$.

  • The $tmnxIomRsrcResourceType$ resources on card $tmnxChassisNotifyCardSlotNum$ have been exhausted at $tmnxIomRsrcTimeEventOccured$. Current utilization is $tmnxIomRsrcUsagePercent$%%.

Cause

The tmnxIomRsrcUsageExhausted notification is generated when all the IOM resources of type tmnxIomRsrcResourceType have been exhausted.

Effect

The specified IOM resource has reached its limit. Some traffic may be affected.

Recovery

Intervention may be required to recover resources.

tmnxIomRsrcUsageHighLimitReached

Table 204. tmnxIomRsrcUsageHighLimitReached properties

Property name

Value

Application name

CHASSIS

Event ID

3252

Event name

tmnxIomRsrcUsageHighLimitReached

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.252

Default severity

warning

Message format string

Possible messages:

  • The $tmnxIomRsrcResourceType$ resources on card $tmnxChassisNotifyCardSlotNum$ have reached or exceeded the high utilization threshold at $tmnxIomRsrcTimeEventOccured$.

  • The $tmnxIomRsrcResourceType$ resources on card $tmnxChassisNotifyCardSlotNum$ have reached or exceeded the high utilization threshold at $tmnxIomRsrcTimeEventOccured$. Current utilization is $tmnxIomRsrcUsagePercent$%%.

Cause

The tmnxIomRsrcUsageHighLimitReached notification is generated when the utilization of the IOM resource of type tmnxIomRsrcResourceType reaches or exceeds the high utilization threshold.

Effect

The specified IOM resource is getting close to exhaustion.

Recovery

There is no recovery required for this notification.

tmnxIomRsrcUsageRecovered

Table 205. tmnxIomRsrcUsageRecovered properties

Property name

Value

Application name

CHASSIS

Event ID

3254

Event name

tmnxIomRsrcUsageRecovered

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.254

Default severity

minor

Message format string

Possible messages:

  • The $tmnxIomRsrcResourceType$ resources on card $tmnxChassisNotifyCardSlotNum$ have dropped below the warning utilization threshold at $tmnxIomRsrcTimeEventOccured$.

  • The $tmnxIomRsrcResourceType$ resources on card $tmnxChassisNotifyCardSlotNum$ have dropped below the warning utilization threshold at $tmnxIomRsrcTimeEventOccured$. Current utilization is $tmnxIomRsrcUsagePercent$%%.

Cause

The tmnxIomRsrcUsageRecovered notification is generated when the utilization of the IOM resource of type tmnxIomRsrcResourceType drops below the warning threshold.

Effect

The utilization of the specified IOM resource has dropped below the warning threshold.

Recovery

There is no recovery required for this notification.

tmnxIPMacCpmFilterOverload

Table 206. tmnxIPMacCpmFilterOverload properties

Property name

Value

Application name

CHASSIS

Event ID

2183

Event name

tmnxIPMacCpmFilterOverload

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.172

Default severity

critical

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has an IPv4 or MAC CPM Filter in overload.

Cause

The tmnxIPMacCpmFilterOverload notification is generated when an IPv4 or MAC CPM Filter policy is in overload on an FP.

Effect

The impacted IPv4 or MAC CPM Filter policy on the affected FP will not work as expected, because not all entries are programmed.

Recovery

Identify the impacted IPv4 or MAC CPM Filter policy, policy entries, and FPs using the appropriate tools commands. Remove or modify policy entries or change the policy assigned to the impacted FPs until the overload condition is cleared.

tmnxIPMacCpmFilterOverloadClear

Table 207. tmnxIPMacCpmFilterOverloadClear properties

Property name

Value

Application name

CHASSIS

Event ID

2184

Event name

tmnxIPMacCpmFilterOverloadClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.173

Default severity

cleared

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has an IPv4 or MAC CPM Filter in overload.

Cause

The tmnxIPMacCpmFilterOverloadClear notification is generated when IPv4 or MAC CPM Filter policies are no longer in overload on an FP.

Effect

The IPv4 or MAC CPM Filter policies on the affected FP will work as expected, because all entries are programmed.

Recovery

No recovery required.

tmnxIPMacFilterEgrNearFull

Table 208. tmnxIPMacFilterEgrNearFull properties

Property name

Value

Application name

CHASSIS

Event ID

2277

Event name

tmnxIPMacFilterEgrNearFull

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.199

Default severity

minor

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has egress IPv4 or MAC ACL Filters at near full utilization.

Cause

The tmnxIPMacFilterEgrNearFull notification is generated when an egress IPv4 or MAC ACL Filter policies are near full utilization on an FP.

Effect

There is no operational impact due to this event.

Recovery

None required.

tmnxIPMacFilterEgrNearFullClear

Table 209. tmnxIPMacFilterEgrNearFullClear properties

Property name

Value

Application name

CHASSIS

Event ID

2278

Event name

tmnxIPMacFilterEgrNearFullClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.200

Default severity

cleared

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has egress IPv4 or MAC ACL Filters near full utilization.

Cause

The tmnxIPMacFilterEgrNearFullClear notification is generated when egress IPv4 or MAC ACL Filter policies are no longer near full utilization on an FP.

Effect

There is no operational impact due to this event.

Recovery

None required.

tmnxIPMacFilterEgrOverload

Table 210. tmnxIPMacFilterEgrOverload properties

Property name

Value

Application name

CHASSIS

Event ID

2177

Event name

tmnxIPMacFilterEgrOverload

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.166

Default severity

critical

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has an egress IPv4 or MAC ACL Filter in overload.

Cause

The tmnxIPMacFilterEgrOverload notification is generated when an egress IPv4 or MAC ACL Filter policy is in overload on an FP.

Effect

The impacted egress IPv4 or MAC ACL Filter policy on the affected FP will not work as expected, because not all entries are programmed.

Recovery

Identify the impacted egress IPv4 or MAC ACL Filter policy, policy entries, and FPs using the appropriate tools commands. Remove or modify policy entries or change the policy assigned to the impacted FPs until the overload condition is cleared.

tmnxIPMacFilterEgrOverloadClear

Table 211. tmnxIPMacFilterEgrOverloadClear properties

Property name

Value

Application name

CHASSIS

Event ID

2178

Event name

tmnxIPMacFilterEgrOverloadClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.167

Default severity

cleared

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has an egress IPv4 or MAC ACL Filter in overload.

Cause

The tmnxIPMacFilterEgrOverloadClear notification is generated when egress IPv4 or MAC ACL Filter policies are no longer in overload on an FP.

Effect

The egress IPv4 or MAC ACL Filter policies on the affected FP will work as expected, because all entries are programmed.

Recovery

No recovery required.

tmnxIPMacFilterIngNearFull

Table 212. tmnxIPMacFilterIngNearFull properties

Property name

Value

Application name

CHASSIS

Event ID

2275

Event name

tmnxIPMacFilterIngNearFull

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.197

Default severity

minor

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has ingress IPv4 or MAC ACL Filters at near full utilization.

Cause

The tmnxIPMacFilterIngNearFull notification is generated when an ingress IPv4 or MAC ACL Filter policies are near full utilization on an FP.

Effect

There is no operational impact due to this event.

Recovery

None required.

tmnxIPMacFilterIngNearFullClear

Table 213. tmnxIPMacFilterIngNearFullClear properties

Property name

Value

Application name

CHASSIS

Event ID

2276

Event name

tmnxIPMacFilterIngNearFullClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.198

Default severity

cleared

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has ingress IPv4 or MAC ACL Filters at near full utilization.

Cause

The tmnxIPMacFilterIngNearFullClear notification is generated when ingress IPv4 or MAC ACL Filter policies are no longer near full utilization on an FP.

Effect

There is no operational impact due to this event.

Recovery

None required.

tmnxIPMacFilterIngOverload

Table 214. tmnxIPMacFilterIngOverload properties

Property name

Value

Application name

CHASSIS

Event ID

2175

Event name

tmnxIPMacFilterIngOverload

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.164

Default severity

critical

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has an ingress IPv4 or MAC ACL Filter in overload.

Cause

The tmnxIPMacFilterIngOverload notification is generated when an ingress IPv4 or MAC ACL Filter policy is in overload on an FP.

Effect

The impacted ingress IPv4 or MAC ACL Filter policy on the affected FP will not work as expected, because not all entries are programmed.

Recovery

Identify the impacted ingress IPv4 or MAC ACL Filter policy, policy entries, and FPs using the appropriate tools commands. Remove or modify policy entries or change the policy assigned to the impacted FPs until the overload condition is cleared.

tmnxIPMacFilterIngOverloadClear

Table 215. tmnxIPMacFilterIngOverloadClear properties

Property name

Value

Application name

CHASSIS

Event ID

2176

Event name

tmnxIPMacFilterIngOverloadClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.165

Default severity

cleared

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has an ingress IPv4 or MAC ACL Filter in overload.

Cause

The tmnxIPMacFilterIngOverloadClear notification is generated when ingress IPv4 or MAC ACL Filter policies are no longer in overload on an FP.

Effect

The ingress IPv4 or MAC ACL Filter policies on the affected FP will work as expected, because all entries are programmed.

Recovery

No recovery required.

tmnxIPMacQosIngOverload

Table 216. tmnxIPMacQosIngOverload properties

Property name

Value

Application name

CHASSIS

Event ID

2167

Event name

tmnxIPMacQosIngOverload

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.156

Default severity

major

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has an ingress QoS policy with IPv4 or MAC criteria entries in overload.

Cause

The tmnxIPMacQosIngOverload notification is generated when an ingress QoS policy is in overload on an FP due to its configured IPv4 or MAC criteria entries.

Effect

The impacted IPv4 or MAC criteria entries in the ingress QoS policy on the affected FP will not work as expected, because not all entries are programmed.

Recovery

Identify the impacted ingress QoS policy, policy entries, and FPs using the appropriate tools commands. Remove or modify the policy criteria entries or change the policy assigned to the impacted FPs until the overload condition is cleared.

tmnxIPMacQosIngOverloadClear

Table 217. tmnxIPMacQosIngOverloadClear properties

Property name

Value

Application name

CHASSIS

Event ID

2168

Event name

tmnxIPMacQosIngOverloadClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.157

Default severity

cleared

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has an ingress QoS policy with IPv4 or MAC criteria entries in overload.

Cause

The tmnxIPMacQosIngOverloadClear notification is generated when ingress QoS policies are no longer in overload on an FP.

Effect

The IPv4 or MAC criteria entries in the ingress QoS policies on the affected FP will work as expected, because all entries are programmed.

Recovery

No recovery required.

tmnxIPQosEgrOverload

Table 218. tmnxIPQosEgrOverload properties

Property name

Value

Application name

CHASSIS

Event ID

2169

Event name

tmnxIPQosEgrOverload

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.158

Default severity

major

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has an egress QoS policy with IPv4 criteria entries in overload.

Cause

The tmnxIPQosEgrOverload notification is generated when an egress QoS policy is in overload on an FP due to its configured IPv4 criteria entries.

Effect

The impacted IPv4 criteria entries in the egress QoS policy on the affected FP will not work as expected, because not all entries are programmed.

Recovery

Identify the impacted egress QoS policy, policy entries, and FPs using the appropriate tools commands. Remove or modify the policy criteria entries or change the policy assigned to the impacted FPs until the overload condition is cleared.

tmnxIPQosEgrOverloadClear

Table 219. tmnxIPQosEgrOverloadClear properties

Property name

Value

Application name

CHASSIS

Event ID

2170

Event name

tmnxIPQosEgrOverloadClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.159

Default severity

cleared

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has an egress QoS policy with IPv4 criteria entries in overload.

Cause

The tmnxIPQosEgrOverloadClear notification is generated when egress QoS policies are no longer in overload on an FP.

Effect

The IPv4 criteria entries in the egress QoS policy on the affected FP will work as expected, because all entries are programmed.

Recovery

No recovery required.

tmnxIPsecIsaGrpActiveIsaChgd

Table 220. tmnxIPsecIsaGrpActiveIsaChgd properties

Property name

Value

Application name

CHASSIS

Event ID

2062

Event name

tmnxIPsecIsaGrpActiveIsaChgd

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.50

Default severity

minor

Message format string

Active ISA changed to $tmnxIPsecIsaGrpActiveIsa$ for IPsec ISA group $tmnxIPsecIsaGrpId$ where primary ISA is $tmnxIPsecIsaGrpPrimaryIsa$ and Backup ISA is $tmnxIPsecIsaGrpBackupIsa$

Cause

The tmnxIPsecIsaGrpActiveIsaChgd notification is generated when a change in the active ISA (Integrated Service Adaptor) occurs in an IPsec ISA module group.

Effect

N/A

Recovery

N/A

tmnxIPsecIsaGrpTnlHighWMark

Table 221. tmnxIPsecIsaGrpTnlHighWMark properties

Property name

Value

Application name

CHASSIS

Event ID

2066

Event name

tmnxIPsecIsaGrpTnlHighWMark

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.54

Default severity

minor

Message format string

Number of tunnels for an IPsec ISA module for the group $tmnxIPsecIsaGrpId$ has reached to the high watermark which is 95% of the maximum limit $tmnxIPsecIsaGrpMaxTunnels$.

Cause

The number of tunnels for an IPsec ISA (Integrated Service Adaptor) module has reached to the high watermark which is 95% of the maximum limit.

Effect

N/A

Recovery

N/A

tmnxIPsecIsaGrpTnlLowWMark

Table 222. tmnxIPsecIsaGrpTnlLowWMark properties

Property name

Value

Application name

CHASSIS

Event ID

2065

Event name

tmnxIPsecIsaGrpTnlLowWMark

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.53

Default severity

minor

Message format string

Number of tunnels for an IPsec ISA module for the group $tmnxIPsecIsaGrpId$ has dropped to the low watermark which is 90% of the maximum limit $tmnxIPsecIsaGrpMaxTunnels$.

Cause

The number of tunnels for an IPsec ISA (Integrated Service Adaptor) module has dropped to the low watermark which is 90% of the maximum limit.

Effect

N/A

Recovery

N/A

tmnxIPsecIsaGrpTnlMax

Table 223. tmnxIPsecIsaGrpTnlMax properties

Property name

Value

Application name

CHASSIS

Event ID

2067

Event name

tmnxIPsecIsaGrpTnlMax

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.55

Default severity

minor

Message format string

Number of tunnels for an IPsec ISA module for the group $tmnxIPsecIsaGrpId$ has reached the maximum limit $tmnxIPsecIsaGrpMaxTunnels$.

Cause

The number of tunnels for an IPsec ISA (Integrated Service Adaptor) module has reached the maximum limit.

Effect

N/A

Recovery

N/A

tmnxIPsecIsaGrpUnableToSwitch

Table 224. tmnxIPsecIsaGrpUnableToSwitch properties

Property name

Value

Application name

CHASSIS

Event ID

2064

Event name

tmnxIPsecIsaGrpUnableToSwitch

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.52

Default severity

minor

Message format string

IPsec ISA $tmnxIPsecIsaGrpActiveIsa$ for group $tmnxIPsecIsaGrpId$ is unable to switch due to lack of resources on the destination MDA

Cause

IPsec ISA group is unable to switch due to lack of resources on the destination MDA.

Effect

In such an event the IPsec ISA group is left without an active MDA and the tmnxIPsecIsaGrpOperState is set to 'outOfService'.

Recovery

Recovery is possible by releasing resources and performing a shutdown/no shutdown operation to bring up the ISA group.

tmnxIPv6CpmFilterOverload

Table 225. tmnxIPv6CpmFilterOverload properties

Property name

Value

Application name

CHASSIS

Event ID

2185

Event name

tmnxIPv6CpmFilterOverload

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.174

Default severity

critical

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has an IPv6 CPM Filter in overload.

Cause

The tmnxIPv6CpmFilterOverload notification is generated when an IPv6 CPM Filter policy is in overload on an FP.

Effect

The impacted IPv6 CPM Filter policy on the affected FP will not work as expected, because not all entries are programmed.

Recovery

Identify the impacted IPv6 CPM Filter policy, policy entries, and FPs using the appropriate tools commands. Remove or modify policy entries or change the policy assigned to the impacted FPs until the overload condition is cleared.

tmnxIPv6CpmFilterOverloadClear

Table 226. tmnxIPv6CpmFilterOverloadClear properties

Property name

Value

Application name

CHASSIS

Event ID

2186

Event name

tmnxIPv6CpmFilterOverloadClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.175

Default severity

cleared

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has an IPv6 CPM Filter in overload.

Cause

The tmnxIPv6CpmFilterOverloadClear notification is generated when IPv6 CPM Filter policies are no longer in overload on an FP.

Effect

The IPv6 CPM Filter policies on the affected FP will work as expected, because all entries are programmed.

Recovery

No recovery required.

tmnxIPv6FilterEgrNearFull

Table 227. tmnxIPv6FilterEgrNearFull properties

Property name

Value

Application name

CHASSIS

Event ID

2281

Event name

tmnxIPv6FilterEgrNearFull

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.203

Default severity

minor

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has egress IPv6 ACL Filters at near full utilization.

Cause

The tmnxIPv6FilterEgrNearFull notification is generated when an egress IPv6 ACL Filter policies are near full utilization on an FP.

Effect

There is no operational impact due to this event.

Recovery

None required.

tmnxIPv6FilterEgrNearFullClear

Table 228. tmnxIPv6FilterEgrNearFullClear properties

Property name

Value

Application name

CHASSIS

Event ID

2282

Event name

tmnxIPv6FilterEgrNearFullClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.204

Default severity

cleared

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has egress IPv6 ACL Filters at near full utilization.

Cause

The tmnxIPv6FilterEgrNearFullClear notification is generated when egress IPv6 ACL Filter policies are no longer near full utilization on an FP.

Effect

There is no operational impact due to this event.

Recovery

None required.

tmnxIPv6FilterEgrOverload

Table 229. tmnxIPv6FilterEgrOverload properties

Property name

Value

Application name

CHASSIS

Event ID

2181

Event name

tmnxIPv6FilterEgrOverload

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.170

Default severity

critical

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has an egress IPv6 ACL Filter in overload.

Cause

The tmnxIPv6FilterEgrOverload notification is generated when an egress IPv6 ACL Filter policy is in overload on an FP.

Effect

The impacted egress IPv6 ACL Filter policy on the affected FP will not work as expected, because not all entries are programmed.

Recovery

Identify the impacted egress IPv6 ACL Filter policy, policy entries, and FPs using the appropriate tools commands. Remove or modify policy entries or changed the policy assigned to the impacted FPs until the overload condition is cleared.

tmnxIPv6FilterEgrOverloadClear

Table 230. tmnxIPv6FilterEgrOverloadClear properties

Property name

Value

Application name

CHASSIS

Event ID

2182

Event name

tmnxIPv6FilterEgrOverloadClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.171

Default severity

cleared

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has an egress IPv6 ACL Filter in overload.

Cause

The tmnxIPv6FilterEgrOverloadClear notification is generated when egress IPv6 ACL Filter policies are no longer in overload on an FP.

Effect

The egress IPv6 ACL Filter policies on the affected FP will work as expected, because all entries are programmed.

Recovery

No recovery required.

tmnxIPv6FilterIngNearFull

Table 231. tmnxIPv6FilterIngNearFull properties

Property name

Value

Application name

CHASSIS

Event ID

2279

Event name

tmnxIPv6FilterIngNearFull

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.201

Default severity

minor

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has ingress IPv6 ACL Filters at near full utilization.

Cause

The tmnxIPv6FilterIngNearFull notification is generated when an ingress IPv6 ACL Filter policies are near full utilization on an FP.

Effect

There is no operational impact due to this event.

Recovery

None required.

tmnxIPv6FilterIngNearFullClear

Table 232. tmnxIPv6FilterIngNearFullClear properties

Property name

Value

Application name

CHASSIS

Event ID

2280

Event name

tmnxIPv6FilterIngNearFullClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.202

Default severity

cleared

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has ingress IPv6 ACL Filters at near full utilization.

Cause

The tmnxIPv6FilterIngNearFullClear notification is generated when ingress IPv6 ACL Filter policies are no longer near full utilization on an FP.

Effect

There is no operational impact due to this event.

Recovery

None required.

tmnxIPv6FilterIngOverload

Table 233. tmnxIPv6FilterIngOverload properties

Property name

Value

Application name

CHASSIS

Event ID

2179

Event name

tmnxIPv6FilterIngOverload

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.168

Default severity

critical

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has an ingress IPv6 ACL Filter in overload.

Cause

The tmnxIPv6FilterIngOverload notification is generated when an ingress IPv6 ACL Filter policy is in overload on a FP.

Effect

The impacted ingress IPv6 ACL Filter policy on the affected FP will not work as expected, because not all entries are programmed.

Recovery

Identify the impacted ingress IPv6 ACL Filter policy, policy entries, and FPs using the appropriate tools commands. Remove or modify policy entries or change the policy assigned to the impacted FPs until the overload condition is cleared.

tmnxIPv6FilterIngOverloadClear

Table 234. tmnxIPv6FilterIngOverloadClear properties

Property name

Value

Application name

CHASSIS

Event ID

2180

Event name

tmnxIPv6FilterIngOverloadClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.169

Default severity

cleared

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has an ingress IPv6 ACL Filter in overload.

Cause

The tmnxIPv6FilterIngOverloadClear notification is generated when ingress IPv6 ACL Filter policies are no longer in overload on an FP.

Effect

The ingress IPv6 ACL Filter policies on the affected FP will work as expected, because all entries are programmed.

Recovery

No recovery required.

tmnxIPv6QosEgrOverload

Table 235. tmnxIPv6QosEgrOverload properties

Property name

Value

Application name

CHASSIS

Event ID

2173

Event name

tmnxIPv6QosEgrOverload

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.162

Default severity

major

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has an egress QoS policy with IPv6 criteria entries in overload.

Cause

The tmnxIPv6QosEgrOverload notification is generated when an egress QoS policy is in overload on an FP due to its configured IPv6 criteria entries.

Effect

The impacted IPv6 criteria entries in the egress QoS Policy on the affected FP will not work as expected, because not all entries are programmed.

Recovery

Identify the impacted egress QoS policy, policy entries, and FPs using the appropriate tools commands. Remove or modify the policy criteria entries or change the policy assigned to the impacted FPs until the overload condition is cleared.

tmnxIPv6QosEgrOverloadClear

Table 236. tmnxIPv6QosEgrOverloadClear properties

Property name

Value

Application name

CHASSIS

Event ID

2174

Event name

tmnxIPv6QosEgrOverloadClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.163

Default severity

cleared

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has an egress QoS policy with IPv6 criteria entries in overload.

Cause

The tmnxIPv6QosEgrOverloadClear notification is generated when egress QoS policies are no longer in overload on an FP.

Effect

The IPv6 criteria entries in the egress QoS policy on the affected FP will work as expected, because all entries are programmed.

Recovery

No recovery required.

tmnxIPv6QosIngOverload

Table 237. tmnxIPv6QosIngOverload properties

Property name

Value

Application name

CHASSIS

Event ID

2171

Event name

tmnxIPv6QosIngOverload

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.160

Default severity

major

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ has an ingress QoS policy with IPv6 criteria entries in overload.

Cause

The tmnxIPv6QosIngOverload notification is generated when an ingress QoS policy is in overload on an FP due to its configured IPv6 criteria entries.

Effect

The impacted IPv6 criteria entries in the ingress QoS policy on the affected FP will not work as expected, because not all entries are programmed.

Recovery

Identify the impacted ingress QoS policy, policy entries, and FPs using the appropriate tools commands. Remove or modify the policy criteria entries or change the policy assigned to the impacted FPs until the overload condition is cleared.

tmnxIPv6QosIngOverloadClear

Table 238. tmnxIPv6QosIngOverloadClear properties

Property name

Value

Application name

CHASSIS

Event ID

2172

Event name

tmnxIPv6QosIngOverloadClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.161

Default severity

cleared

Message format string

Slot $tmnxChassisNotifyCardSlotNum$ FP $tmnxChassisNotifyFpNum$ no longer has an ingress QoS policy with IPv6 criteria entries in overload.

Cause

The tmnxIPv6QosIngOverloadClear notification is generated when ingress QoS policies are no longer in overload on an FP.

Effect

The IPv6 criteria entries in the ingress QoS policy on the affected FP will work as expected, because all entries are programmed.

Recovery

No recovery required.

tmnxMDAIsaTunnelGroupChange

Table 239. tmnxMDAIsaTunnelGroupChange properties

Property name

Value

Application name

CHASSIS

Event ID

2083

Event name

tmnxMDAIsaTunnelGroupChange

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.71

Default severity

minor

Message format string

MDA $tmnxCardSlotNum$/ $tmnxMDASlotNum$ is $tmnxMDAIsaTunnelGroupInUse$ active in the ISA tunnel-group $tmnxMDAIsaTunnelGroup$

Cause

The tmnxMDAIsaTunnelGroupChange notification is generated when IPsec ISA (Integrated Service Adaptor) tunnel-group in-use for the MDA changes value.

Effect

There is no operational impact due to this event.

Recovery

N/A

tmnxPeBootloaderVersionMismatch

Table 240. tmnxPeBootloaderVersionMismatch properties

Property name

Value

Application name

CHASSIS

Event ID

2027

Event name

tmnxPeBootloaderVersionMismatch

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.35

Default severity

major

Message format string

Class $tmnxHwClass$ : Bootloader version mismatch - expected software version $tmnxHwSoftwareCodeVersion$, equipped version $tmnxChassisNotifyMismatchedVer$

Cause

Generated when there is a mismatch between the CPM and boot loader versions. tmnxChassisNotifyHwIndex identifies the CPM card. tmnxChassisNotifyMismatchedVer contains the mismatched version of bootloader and tmnxHwSoftwareCodeVersion contains the expected version of the bootloader.

Effect

N/A

Recovery

N/A

tmnxPeBootromVersionMismatch

Table 241. tmnxPeBootromVersionMismatch properties

Property name

Value

Application name

CHASSIS

Event ID

2028

Event name

tmnxPeBootromVersionMismatch

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.36

Default severity

major

Message format string

Class $tmnxHwClass$ : Bootrom version mismatch - expected version $tmnxHwSoftwareCodeVersion$, equipped version $tmnxChassisNotifyMismatchedVer$

Cause

Generated when there is a mismatch between the boot rom versions. tmnxChassisNotifyHwIndex identifies the IOM card. tmnxChassisNotifyMismatchedVer contains the mismatched version of bootrom and tmnxHwSoftwareCodeVersion contains the expected version of the bootrom.

Effect

N/A

Recovery

N/A

tmnxPeFirmwareVersionWarning

Table 242. tmnxPeFirmwareVersionWarning properties

Property name

Value

Application name

CHASSIS

Event ID

2082

Event name

tmnxPeFirmwareVersionWarning

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.70

Default severity

warning

Message format string

Class $tmnxHwClass$ : Firmware version $tmnxHwFirmwareCodeVersion$ is compatible but not the latest. Hard reset the MDA/IMM to upgrade to the most recent firmware if desired.

Cause

Generated when a card is running compatible yet older firmware than the firmware associated with the current software release. tmnxChassisNotifyHwIndex identifies the card. The tmnxHwFirmwareCodeVersion object will contain the programmed the firmware version.

Effect

N/A

Recovery

N/A

tmnxPeFPGAVersionMismatch

Table 243. tmnxPeFPGAVersionMismatch properties

Property name

Value

Application name

CHASSIS

Event ID

2029

Event name

tmnxPeFPGAVersionMismatch

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.37

Default severity

major

Message format string

Class $tmnxHwClass$ : FPGA version mismatch - expected version $tmnxHwSoftwareCodeVersion$, equipped version $tmnxChassisNotifyMismatchedVer$

Cause

Generated when there is a mismatch between the FPGA versions. tmnxChassisNotifyHwIndex identifies the IOM card. tmnxChassisNotifyMismatchedVer contains the mismatched version of FPGA and tmnxHwSoftwareCodeVersion contains the expected version of the FPGA.

Effect

N/A

Recovery

N/A

tmnxPeKernelVersionMismatch

Table 244. tmnxPeKernelVersionMismatch properties

Property name

Value

Application name

CHASSIS

Event ID

2221

Event name

tmnxPeKernelVersionMismatch

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.232

Default severity

major

Message format string

Class $tmnxHwClass$ : Kernel version mismatch - expected software version $tmnxHwSoftwareCodeVersion$, equipped version $tmnxChassisNotifyMismatchedVer$

Cause

This notification is generated when there is a mismatch between the software version of the host kernel software and the CPM software. This may occur if the user updates the system software without following the recommended software upgrade procedures. The object tmnxChassisNotifyHwIndex identifies the CPM card. The object tmnxChassisNotifyMismatchedVer contains the version of the host kernel software and tmnxHwSoftwareCodeVersion contains the version of the CPM software. This notification is only applicable to systems that use both host kernel software and CPM software, such as the 7705 SAR-Hm and the 7250 IXR-s.

Effect

Although the system may appear to work properly, the behavior of the system in this state is undefined. Using mismatched versions of host kernel software and CPM software is not supported.

Recovery

Follow the recommended software upgrade procedures to update the host kernel software and CPM software to the desired software release.

tmnxPeSoftwareLoadFailed

Table 245. tmnxPeSoftwareLoadFailed properties

Property name

Value

Application name

CHASSIS

Event ID

2026

Event name

tmnxPeSoftwareLoadFailed

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.34

Default severity

major

Message format string

Class $tmnxHwClass$ : Failed to load software from $tmnxChassisNotifySoftwareLocation$

Cause

Generated when the CPM fails to load the software from a specified location. tmnxChassisNotifyHwIndex identifies the card for which the software load failed and tmnxChassisNotifySoftwareLocation contains the location from where the software load was attempted.

Effect

N/A

Recovery

N/A

tmnxPeSoftwareVersionMismatch

Table 246. tmnxPeSoftwareVersionMismatch properties

Property name

Value

Application name

CHASSIS

Event ID

2025

Event name

tmnxPeSoftwareVersionMismatch

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.16

Default severity

major

Message format string

Class $tmnxHwClass$ : Software version mismatch - expected software version $tmnxHwSoftwareCodeVersion$, equipped version $tmnxChassisNotifyMismatchedVer$

Cause

Generated when there is a mismatch between software versions of the active CPM and standby CPM or the CPM and IOM. tmnxChassisNotifyHwIndex identifies the mismatched CPM/IOM card and tmnxChassisNotifyMismatchedVer will contain the version of the mismatched card. The tmnxHwSoftwareCodeVersion object will contain the expected version.

Effect

N/A

Recovery

N/A

tmnxPhysChassisFilterDoorClosed

Table 247. tmnxPhysChassisFilterDoorClosed properties

Property name

Value

Application name

CHASSIS

Event ID

2195

Event name

tmnxPhysChassisFilterDoorClosed

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.194

Default severity

cleared

Message format string

Filter door is closed

Cause

The tmnxPhysChassisFilterDoorClosed notification is generated when the filter door is present and closed.

Effect

The power shelves are protected by the closed door.

Recovery

No recovery required.

tmnxPhysChassisFilterDoorOpen

Table 248. tmnxPhysChassisFilterDoorOpen properties

Property name

Value

Application name

CHASSIS

Event ID

2194

Event name

tmnxPhysChassisFilterDoorOpen

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.193

Default severity

minor

Message format string

Filter door is missing or open

Cause

The tmnxPhysChassisFilterDoorOpen notification is generated when the filter door is either open or not present.

Effect

Power shelf protection may be compromised.

Recovery

If the filter door is not installed, install it. Close the filter door.

tmnxPhysChassisPCMInputFeed

Table 249. tmnxPhysChassisPCMInputFeed properties

Property name

Value

Application name

CHASSIS

Event ID

2165

Event name

tmnxPhysChassisPCMInputFeed

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.154

Default severity

minor

Message format string

Chassis $tmnxPhysChassisNum$ pcm $tmnxPhysChassisPCMId$ $tmnxPhysChassisPCMInFeedDown$not supplying power.

Cause

The tmnxPhysChassisPCMInputFeed notification is generated if any one of the input feeds for a given PCM has gone offline.

Effect

There is an increased risk of system power brown-outs or black-outs.

Recovery

Restore all of the input feeds that are not supplying power.

tmnxPhysChassisPCMInputFeedClr

Table 250. tmnxPhysChassisPCMInputFeedClr properties

Property name

Value

Application name

CHASSIS

Event ID

2166

Event name

tmnxPhysChassisPCMInputFeedClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.155

Default severity

cleared

Message format string

The input feeds for chassis $tmnxPhysChassisNum$ pcm $tmnxPhysChassisPCMId$ are supplying power.

Cause

The tmnxPhysChassisPCMInputFeedClr notification is generated when the last of the missing input feeds for a given PCM has been brought back online.

Effect

All PCM input feeds are supplying power.

Recovery

No recovery required.

tmnxPhysChassisPMInputFeed

Table 251. tmnxPhysChassisPMInputFeed properties

Property name

Value

Application name

CHASSIS

Event ID

2192

Event name

tmnxPhysChassisPMInputFeed

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.191

Default severity

minor

Message format string

Power module $tmnxHwIndex$ $tmnxPhysChassisPMInputFeedDown$not supplying power.

Cause

The tmnxPhysChassisPMInputFeed notification is generated if any one of the input feeds for a given power module is not supplying power.

Effect

There is an increased risk of system power brownouts or blackouts.

Recovery

Restore all of the input feeds that are not supplying power.

tmnxPhysChassisPMInputFeedClr

Table 252. tmnxPhysChassisPMInputFeedClr properties

Property name

Value

Application name

CHASSIS

Event ID

2193

Event name

tmnxPhysChassisPMInputFeedClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.192

Default severity

cleared

Message format string

The input feeds for power module $tmnxHwIndex$ are supplying power.

Cause

The tmnxPhysChassPwrSupInputFeedClr notification is generated when the last of the missing input feeds has been brought back online.

Effect

All power module input feeds are supplying power.

Recovery

No recovery required.

tmnxPhysChassisPMOutFail

Table 253. tmnxPhysChassisPMOutFail properties

Property name

Value

Application name

CHASSIS

Event ID

2190

Event name

tmnxPhysChassisPMOutFail

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.189

Default severity

critical

Message format string

Power module $tmnxHwIndex$ output failure

Cause

The tmnxPhysChassisPMOutFail notification is generated when an output failure occurs on the power module.

Effect

The power module is no longer operational.

Recovery

Insert a new power module.

tmnxPhysChassisPMOutFailClr

Table 254. tmnxPhysChassisPMOutFailClr properties

Property name

Value

Application name

CHASSIS

Event ID

2191

Event name

tmnxPhysChassisPMOutFailClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.190

Default severity

cleared

Message format string

Power module $tmnxHwIndex$ output failure cleared

Cause

The tmnxPhysChassisPMOutFailClr notification is generated when an output failure is cleared on the power module.

Effect

The power module is operational again.

Recovery

There is no recovery for this notification.

tmnxPhysChassisPMOverTemp

Table 255. tmnxPhysChassisPMOverTemp properties

Property name

Value

Application name

CHASSIS

Event ID

2196

Event name

tmnxPhysChassisPMOverTemp

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.195

Default severity

critical

Message format string

$tmnxHwIndex$ over temperature

Cause

The tmnxPhysChassisPMOverTemp notification is generated when a power module's temperature surpasses the temperature threshold.

Effect

The power module is no longer operational.

Recovery

Check input feed and/or insert a new power module.

tmnxPhysChassisPMOverTempClr

Table 256. tmnxPhysChassisPMOverTempClr properties

Property name

Value

Application name

CHASSIS

Event ID

2197

Event name

tmnxPhysChassisPMOverTempClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.196

Default severity

cleared

Message format string

$tmnxHwIndex$ over temperature cleared

Cause

The tmnxPhysChassisPMOverTempClr notification is generated when a power module's temperature is reduced below the temperature threshold.

Effect

The power module is operational again.

Recovery

There is no recovery for this notification.

tmnxPhysChassPwrSupInputFeed

Table 257. tmnxPhysChassPwrSupInputFeed properties

Property name

Value

Application name

CHASSIS

Event ID

2159

Event name

tmnxPhysChassPwrSupInputFeed

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.146

Default severity

minor

Message format string

Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ $tmnxPhysChassPowerSupInFeedDown$not supplying power.

Cause

The tmnxPhysChassPwrSupInputFeed notification is generated if any one of the input feeds for a given power supply is not supplying power.

Effect

There is an increased risk of system power brown-outs or black-outs.

Recovery

Restore all of the input feeds that are not supplying power.

tmnxPhysChassPwrSupInputFeedClr

Table 258. tmnxPhysChassPwrSupInputFeedClr properties

Property name

Value

Application name

CHASSIS

Event ID

2160

Event name

tmnxPhysChassPwrSupInputFeedClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.147

Default severity

cleared

Message format string

The input feeds for chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ are supplying power.

Cause

The tmnxPhysChassPwrSupInputFeedClr notification is generated when the last of the missing input feeds has been brought back online.

Effect

All power supply input feeds are supplying power.

Recovery

No recovery required.

tmnxPhysChassPwrSupPemACRect

Table 259. tmnxPhysChassPwrSupPemACRect properties

Property name

Value

Application name

CHASSIS

Event ID

2157

Event name

tmnxPhysChassPwrSupPemACRect

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.144

Default severity

minor

Message format string

Chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ $tmnxPhysChassPowerSupPemACRect$failed or missing.

Cause

The tmnxPhysChassPwrSupPemACRect notification is generated if any one of the AC rectifiers for a given power supply is in a failed state or is missing.

Effect

There is an increased risk of the power supply failing, causing insufficient power to the system.

Recovery

Bring the AC rectifiers back online.

tmnxPhysChassPwrSupPemACRectClr

Table 260. tmnxPhysChassPwrSupPemACRectClr properties

Property name

Value

Application name

CHASSIS

Event ID

2158

Event name

tmnxPhysChassPwrSupPemACRectClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.145

Default severity

cleared

Message format string

The chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ AC rectifiers are fully operational.

Cause

The tmnxPhysChassPwrSupPemACRectClr notification is generated when the last of the failed or missing AC rectifiers has been brought back online.

Effect

The power supply AC rectifiers are fully operational.

Recovery

No recovery required.

tmnxPhysChassPwrSupWrgFanDir

Table 261. tmnxPhysChassPwrSupWrgFanDir properties

Property name

Value

Application name

CHASSIS

Event ID

2155

Event name

tmnxPhysChassPwrSupWrgFanDir

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.142

Default severity

major

Message format string

The $tmnxPhysChassPowerSupFanDir$ fan direction for chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ is not supported.

Cause

The tmnxPhysChassPwrSupWrgFanDir notification is generated when the airflow direction of the power supply's fan is incorrect.

Effect

The power supply is not cooling properly and may overheat.

Recovery

Replace the power supply with one that has the proper fan direction.

tmnxPhysChassPwrSupWrgFanDirClr

Table 262. tmnxPhysChassPwrSupWrgFanDirClr properties

Property name

Value

Application name

CHASSIS

Event ID

2156

Event name

tmnxPhysChassPwrSupWrgFanDirClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.143

Default severity

cleared

Message format string

The fan direction for chassis $tmnxPhysChassisNum$ power supply $tmnxPhysChassPowerSupId$ has been corrected.

Cause

The tmnxPhysChassPwrSupWrgFanDirClr notification is generated when the airflow direction of the power supply's fan is corrected.

Effect

The fan is cooling the power supply in the proper direction.

Recovery

No recovery required.

tmnxPlcyAcctPlcrPoolExcResource

Table 263. tmnxPlcyAcctPlcrPoolExcResource properties

Property name

Value

Application name

CHASSIS

Event ID

2231

Event name

tmnxPlcyAcctPlcrPoolExcResource

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.242

Default severity

minor

Message format string

Policer Resource usage on card $tmnxCardSlotNum$ and forwarding plane $tmnxFPNum$ exceeds 95 percent of the policer limit. Total policer resource used is ' $tmnxFPPlcyAcctPolicerInUse$' and the limit is '$tmnxFPPlcyAcctPolicerLimit$'

Cause

The tmnxPlcyAcctPlcrPoolExcResource notification is generated when the number of in-use policer resource usage as specified by tmnxFPPlcyAcctPolicerInUse exceeds 95 percent of the policer limit as specified by tmnxFPPlcyAcctPolicerLimit.

Effect

The affected device may not provide accurate and complete statistics.

Recovery

There is no recovery required for this notification.

tmnxPlcyAcctPlcrPoolLowResource

Table 264. tmnxPlcyAcctPlcrPoolLowResource properties

Property name

Value

Application name

CHASSIS

Event ID

2232

Event name

tmnxPlcyAcctPlcrPoolLowResource

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.243

Default severity

minor

Message format string

Policer Resource usage on card $tmnxCardSlotNum$ and forwarding plane $tmnxFPNum$ is below 85 percent of the policer limit. Total policer resource used is ' $tmnxFPPlcyAcctPolicerInUse$' and the limit is '$tmnxFPPlcyAcctPolicerLimit$'

Cause

The tmnxPlcyAcctPlcrPoolLowResource notification is generated when the number of in-use policer resource as specified by tmnxFPPlcyAcctPolicerInUse is below 85 percent of the policer limit as specified by tmnxFPPlcyAcctPolicerLimit.

Effect

The configured policer limit is cleared when the number of in-use policer resources falls below 85 percent of the policer limit.

Recovery

There is no recovery required for this notification.

tmnxPlcyAcctStatsEventOvrflw

Table 265. tmnxPlcyAcctStatsEventOvrflw properties

Property name

Value

Application name

CHASSIS

Event ID

2120

Event name

tmnxPlcyAcctStatsEventOvrflw

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.107

Default severity

minor

Message format string

Policy Accounting FP log event overflow occurred on card $tmnxChassisNotifyCardSlotNum$ at $tmnxPlcyAcctTimeEventOccured$.

Cause

The tmnxPlcyAcctStatsEventOvrflw notification is generated when tmnxPlcyAcctStatsPoolExcResource and tmnxPlcyAcctStatsPoolLowResource occur more than 200 times because of resource usage fluctuation. The IOM raises the final trap to indicate overflow and stops logging traps.

Effect

Some FP notifications configured on the card may not be received.

Recovery

Notifications will resume once the Overflow clear is set.

tmnxPlcyAcctStatsEventOvrflwClr

Table 266. tmnxPlcyAcctStatsEventOvrflwClr properties

Property name

Value

Application name

CHASSIS

Event ID

2119

Event name

tmnxPlcyAcctStatsEventOvrflwClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.106

Default severity

minor

Message format string

$tmnxPlcyAcctMissingNotifCount$ Policy Accounting FP log events were dropped in the last event throttling interval on card $tmnxChassisNotifyCardSlotNum$ at $tmnxPlcyAcctTimeEventOccured$.

Cause

The tmnxPlcyAcctStatsEventOvrflwClr notification is generated when the CPM polls the IOM for traps and the overflow is cleared by logging an overflow-clear on a particular card.

Effect

Notifications are received again since the event throttling has ended.

Recovery

There is no recovery for this notification.

tmnxPlcyAcctStatsPoolExcResource

Table 267. tmnxPlcyAcctStatsPoolExcResource properties

Property name

Value

Application name

CHASSIS

Event ID

2117

Event name

tmnxPlcyAcctStatsPoolExcResource

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.104

Default severity

minor

Message format string

Stats Resource usage on card $tmnxCardSlotNum$ and forwarding plane $tmnxFPNum$ exceeds 95 percent of the stats pool limit. Total stats resource used is ' $tmnxFPPlcyAcctStatsInUse$' and the limit is '$tmnxFPPlcyAcctStatsPool$'

Cause

The tmnxPlcyAcctStatsPoolExcResource notification is generated when the number of in-use stats resource usage as specified by tmnxFPPlcyAcctStatsInUse exceeds 95 percent of the stats pool limit as specified by tmnxFPPlcyAcctStatsPool.

Effect

The affected device may not provide accurate and complete statistics.

Recovery

There is no recovery required for this notification.

tmnxPlcyAcctStatsPoolLowResource

Table 268. tmnxPlcyAcctStatsPoolLowResource properties

Property name

Value

Application name

CHASSIS

Event ID

2118

Event name

tmnxPlcyAcctStatsPoolLowResource

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.105

Default severity

minor

Message format string

Stats Resource usage on card $tmnxCardSlotNum$ and forwarding plane $tmnxFPNum$ is below 85 percent of the stats pool limit. Total stats resource used is ' $tmnxFPPlcyAcctStatsInUse$' and the limit is '$tmnxFPPlcyAcctStatsPool$'

Cause

The tmnxPlcyAcctStatsPoolLowResource notification is generated when the number of in-use stats resource as specified by tmnxFPPlcyAcctStatsInUse is below 85 percent of the stats pool limit as specified by tmnxFPPlcyAcctStatsPool.

Effect

The configured stats pool limit is cleared when the number of in-use stats resources falls below 85 percent of the stats pool limit.

Recovery

There is no recovery required for this notification.

tmnxPowerShelfCommsDown

Table 269. tmnxPowerShelfCommsDown properties

Property name

Value

Application name

CHASSIS

Event ID

6002

Event name

tmnxPowerShelfCommsDown

SNMP notification prefix and OID

TIMETRA-POWER-SHELF-MIB.tmnxPowerShelfNotifications.2

Default severity

minor

Message format string

$tmnxHwIndex$ lost communication with $tmnxCpmPowerShelfCommsFail$

Cause

The tmnxPowerShelfCommsDown is generated when there is a loss of communications with the power shelf controller.

Effect

If there is a power failure, it will not be detected since the power modules cannot be polled. The system will continue to report the state of the power modules as they were when last seen.

Recovery

Correct the power shelf controller communications problem.

tmnxPowerShelfCommsUp

Table 270. tmnxPowerShelfCommsUp properties

Property name

Value

Application name

CHASSIS

Event ID

6003

Event name

tmnxPowerShelfCommsUp

SNMP notification prefix and OID

TIMETRA-POWER-SHELF-MIB.tmnxPowerShelfNotifications.3

Default severity

cleared

Message format string

Re-established communications to $tmnxHwIndex$

Cause

The tmnxPowerShelfCommsUp notification is generated when a loss of communications with the power shelf controller has been resolved.

Effect

Power failures can be detected.

Recovery

No recovery required.

tmnxPowerShelfInputPwrModeSwitch

Table 271. tmnxPowerShelfInputPwrModeSwitch properties

Property name

Value

Application name

CHASSIS

Event ID

6001

Event name

tmnxPowerShelfInputPwrModeSwitch

SNMP notification prefix and OID

TIMETRA-POWER-SHELF-MIB.tmnxPowerShelfNotifications.1

Default severity

minor

Message format string

$tmnxHwIndex$ input power mode switched to $tmnxPowerShelfInputPowerMode$A

Cause

The tmnxPowerShelfInputPwrModeSwitch is generated when tmnxPowerShelfInputPowerMode has changed value.

Effect

No effect.

Recovery

No recovery required.

tmnxPowerShelfOutputStatusDown

Table 272. tmnxPowerShelfOutputStatusDown properties

Property name

Value

Application name

CHASSIS

Event ID

6005

Event name

tmnxPowerShelfOutputStatusDown

SNMP notification prefix and OID

TIMETRA-POWER-SHELF-MIB.tmnxPowerShelfNotifications.5

Default severity

minor

Message format string

$tmnxHwIndex$ output status switched to $tmnxPowerShelfOutputStatus$

Cause

The tmnxPowerShelfOutputStatusSwitch is generated when the physical output switch on the power shelf is set to Standby.

Effect

The power output from the identified power shelf is switched off and does not supply power to the system.

Recovery

Set output switch to On to restore power output.

tmnxPowerShelfOutputStatusSwitch

Table 273. tmnxPowerShelfOutputStatusSwitch properties

Property name

Value

Application name

CHASSIS

Event ID

6004

Event name

tmnxPowerShelfOutputStatusSwitch

SNMP notification prefix and OID

TIMETRA-POWER-SHELF-MIB.tmnxPowerShelfNotifications.4

Default severity

minor

Message format string

$tmnxHwIndex$ output status switched to $tmnxPowerShelfOutputStatus$

Cause

The tmnxPowerShelfOutputStatusSwitch is generated when tmnxPowerShelfOutputStatus has changed value.

Effect

No effect.

Recovery

No recovery required.

tmnxPowerShelfOutputStatusUp

Table 274. tmnxPowerShelfOutputStatusUp properties

Property name

Value

Application name

CHASSIS

Event ID

6006

Event name

tmnxPowerShelfOutputStatusUp

SNMP notification prefix and OID

TIMETRA-POWER-SHELF-MIB.tmnxPowerShelfNotifications.6

Default severity

minor

Message format string

$tmnxHwIndex$ output status switched to $tmnxPowerShelfOutputStatus$

Cause

The tmnxPowerShelfOutputStatusSwitch is generated when the physical output switch on the power shelf is set to On.

Effect

Power output from the identified power shelf is enabled and now supplies power to the system.

Recovery

No recovery required.

tmnxRedPrimaryCPMFail

Table 275. tmnxRedPrimaryCPMFail properties

Property name

Value

Application name

CHASSIS

Event ID

2012

Event name

tmnxRedPrimaryCPMFail

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.21

Default severity

critical

Message format string

Active CPM failed

Cause

Generated when the primary CPM fails.

Effect

N/A

Recovery

N/A

tmnxSasAlarminput1StateChanged

Table 276. tmnxSasAlarminput1StateChanged properties

Property name

Value

Application name

CHASSIS

Event ID

3001

Event name

tmnxSasAlarminput1StateChanged

SNMP notification prefix and OID

TIMETRA-SAS-ALARM-INPUT-MIB.tmnxSasAlarmInputNotifications.1

Default severity

major

Message format string

Alarm Input " $tmnxSasAlarmInputDescription$" has changed status

"$tmnxSasAlarmInputNotifyMessage$"

Cause

A tmnxSasAlarminput1StateChanged notification is sent when status of the alarm input on pin one(1) changes. When this notification is sent, the field tmnxSasAlarmInputNotifyMessage is populated with either the tmnxSasAlarmInputTriggerMessage when the alarm is raised, or the tmnxSasAlarmInputClearMessage when the alarm is cleared. The trigger or clear actions depend on the polarity of the input as defined in tmnxSasAlarmInputPolarity.

Effect

A desirable or undesirable event has occurred in the external equipment connected to the alarm input. Hence the characteristics of effect and the associated risks vary depending on the nature of the external equipment being monitored over the alarm input.

Recovery

Check the external equipment, connected to the alarm input pin one(1), that resulted in this alarm and rectify the problem.

tmnxSasAlarminput2StateChanged

Table 277. tmnxSasAlarminput2StateChanged properties

Property name

Value

Application name

CHASSIS

Event ID

3002

Event name

tmnxSasAlarminput2StateChanged

SNMP notification prefix and OID

TIMETRA-SAS-ALARM-INPUT-MIB.tmnxSasAlarmInputNotifications.2

Default severity

major

Message format string

Alarm Input " $tmnxSasAlarmInputDescription$" has changed status

"$tmnxSasAlarmInputNotifyMessage$"

Cause

A tmnxSasAlarminput2StateChanged notification is sent when status of the alarm input on pin two(2) changes. When this notification is sent, the field tmnxSasAlarmInputNotifyMessage is populated with either the tmnxSasAlarmInputTriggerMessage when the alarm is raised, or the tmnxSasAlarmInputClearMessage when the alarm is cleared. The trigger or clear actions depend on the polarity of the input as defined in tmnxSasAlarmInputPolarity.

Effect

A desirable or undesirable event has occurred in the external equipment connected to the alarm input. Hence the characteristics of effect and the associated risks vary depending on the nature of the external equipment being monitored over the alarm input.

Recovery

Check the external equipment, connected to the alarm input pin two(2), that resulted in this alarm and rectify the problem.

tmnxSasAlarminput3StateChanged

Table 278. tmnxSasAlarminput3StateChanged properties

Property name

Value

Application name

CHASSIS

Event ID

3003

Event name

tmnxSasAlarminput3StateChanged

SNMP notification prefix and OID

TIMETRA-SAS-ALARM-INPUT-MIB.tmnxSasAlarmInputNotifications.3

Default severity

major

Message format string

Alarm Input " $tmnxSasAlarmInputDescription$" has changed status

"$tmnxSasAlarmInputNotifyMessage$"

Cause

A tmnxSasAlarminput3StateChanged notification is sent when status of the alarm input on pin three(3) changes. When this notification is sent, the field tmnxSasAlarmInputNotifyMessage is populated with either the tmnxSasAlarmInputTriggerMessage when the alarm is raised, or the tmnxSasAlarmInputClearMessage when the alarm is cleared. The trigger or clear actions depend on the polarity of the input as defined in tmnxSasAlarmInputPolarity.

Effect

A desirable or undesirable event has occurred in the external equipment connected to the alarm input. Hence the characteristics of effect and the associated risks vary depending on the nature of the external equipment being monitored over the alarm input.

Recovery

Check the external equipment, connected to the alarm input pin three(3), that resulted in this alarm and rectify the problem.

tmnxSasAlarminput4StateChanged

Table 279. tmnxSasAlarminput4StateChanged properties

Property name

Value

Application name

CHASSIS

Event ID

3004

Event name

tmnxSasAlarminput4StateChanged

SNMP notification prefix and OID

TIMETRA-SAS-ALARM-INPUT-MIB.tmnxSasAlarmInputNotifications.4

Default severity

major

Message format string

Alarm Input " $tmnxSasAlarmInputDescription$" has changed status

"$tmnxSasAlarmInputNotifyMessage$"

Cause

A tmnxSasAlarminput4StateChanged notification is sent when status of the alarm input on pin four(4) changes. When this notification is sent, the field tmnxSasAlarmInputNotifyMessage is populated with either the tmnxSasAlarmInputTriggerMessage when the alarm is raised, or the tmnxSasAlarmInputClearMessage when the alarm is cleared. The trigger or clear actions depend on the polarity of the input as defined in tmnxSasAlarmInputPolarity.

Effect

A desirable or undesirable event has occurred in the external equipment connected to the alarm input. Hence the characteristics of effect and the associated risks vary depending on the nature of the external equipment being monitored over the alarm input.

Recovery

Check the external equipment, connected to the alarm input pin four(4), that resulted in this alarm and rectify the problem.

tmnxSfmIcPortDDMClear

Table 280. tmnxSfmIcPortDDMClear properties

Property name

Value

Application name

CHASSIS

Event ID

4026

Event name

tmnxSfmIcPortDDMClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.7

Default severity

minor

Message format string

SFM interconnect port SFF DDM $tmnxDDMLaneIdOrModule$ ($tmnxDDMFailedObject$) cleared

Cause

The tmnxSfmIcPortDDMFailure notification is generated when an SFF in an SFM interconnect port that supports Digital Diagnostic Monitoring (DDM) clears a failed state.

Effect

N/A

Recovery

N/A

tmnxSfmIcPortDDMFailure

Table 281. tmnxSfmIcPortDDMFailure properties

Property name

Value

Application name

CHASSIS

Event ID

4025

Event name

tmnxSfmIcPortDDMFailure

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.6

Default severity

minor

Message format string

SFM interconnect port SFF DDM $tmnxDDMLaneIdOrModule$ ($tmnxDDMFailedObject$) raised

Cause

The tmnxSfmIcPortDDMFailure notification is generated when an SFF in an SFM interconnect port that supports Digital Diagnostic Monitoring (DDM) enters a failed state.

Effect

N/A

Recovery

N/A

tmnxSfmIcPortDegraded

Table 282. tmnxSfmIcPortDegraded properties

Property name

Value

Application name

CHASSIS

Event ID

4027

Event name

tmnxSfmIcPortDegraded

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.8

Default severity

minor

Message format string

Switch fabric capacity associated with the SFM interconnect port is in a $tmnxSfmIcPortDegradeState$ state

Cause

The tmnxSfmIcPortDegraded notification is generated when the system has detected a degradation of the switch fabric that is associated with a particular SFM interconnect port. The value of tmnxSfmIcPortDegradeState will reflect this condition by having a value that is NOT 'none (1)'. If the value of tmnxSfmIcPortDegradeState is 'degraded (2)' the SFM interconnect port can still carry some traffic but not at the full capacity of the port. The port and attached cable are not necessarily the cause of the degradation but are a likely cause.

Effect

Switch fabric capacity on this port is reduced when tmnxSfmIcPortDegradeState is degraded. This may not be causing any impact to service because of redundancy in the fabric.

Recovery

Although it may not be necessary to maintain full service, replacing the affected components may restore some fabric capacity."

tmnxSfmIcPortDegradedClear

Table 283. tmnxSfmIcPortDegradedClear properties

Property name

Value

Application name

CHASSIS

Event ID

4028

Event name

tmnxSfmIcPortDegradedClear

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.9

Default severity

minor

Message format string

Switch fabric capacity associated with the SFM interconnect port is not in a degraded state

Cause

The tmnxSfmIcPortDegradedClear notification is generated when the switch fabric associated with the SFM interconnect port is not degraded. This occurs when the value of tmnxSfmIcPortDegradeState is 'none (1)'."

Effect

N/A

Recovery

N/A

tmnxSfmIcPortDown

Table 284. tmnxSfmIcPortDown properties

Property name

Value

Application name

CHASSIS

Event ID

4017

Event name

tmnxSfmIcPortDown

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.1

Default severity

minor

Message format string

Possible messages:

  • SFM interconnect port is not operational. Error code = $tmnxSfmIcPortOperState$ to Fabric $tmnxSfmIcPortMisconSfm$ IcPort $tmnxSfmIcPortMisconSfmIcPort$

  • SFM interconnect port is not operational. Error code = $tmnxSfmIcPortOperState$

Cause

The tmnxSfmIcPortDown alarm is generated when the SFM interconnect port is not operational. The reason may be a cable connected incorrectly, a disconnected cable, a faulty cable, or a misbehaving SFM interconnect port or SFM card.

Effect

This port can no longer be used as part of the user plane fabric between chassis. Other fabric paths may be available resulting in no loss of capacity.

Recovery

A manual verification and testing of each SFM interconnect port is required to ensure fully functional operation. Physical replacement of cabling may be required.

tmnxSfmIcPortSFFInserted

Table 285. tmnxSfmIcPortSFFInserted properties

Property name

Value

Application name

CHASSIS

Event ID

4019

Event name

tmnxSfmIcPortSFFInserted

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.3

Default severity

minor

Message format string

SFM interconnect port SFF inserted

Cause

The tmnxSfmIcPortSFFInserted notification is generated when the Small Form Factor (SFF) pluggable optical module (eg. CXP) is inserted into an SFM interconnect port.

Effect

This event is for notification only.

Recovery

N/A

tmnxSfmIcPortSFFRemoved

Table 286. tmnxSfmIcPortSFFRemoved properties

Property name

Value

Application name

CHASSIS

Event ID

4020

Event name

tmnxSfmIcPortSFFRemoved

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.4

Default severity

minor

Message format string

SFM interconnect port SFF removed

Cause

The tmnxSfmIcPortSFFRemoved notification is generated when the SFF (eg. CXP) is removed from the SFM interconnect port.

Effect

Removing the module will cause the port to go down. This port can no longer be used as part of the user plane fabric between chassis. Other fabric paths may be available resulting in no loss of capacity.

Recovery

Insert a working SFF into the SFM interconnect port.

tmnxSfmIcPortUp

Table 287. tmnxSfmIcPortUp properties

Property name

Value

Application name

CHASSIS

Event ID

4018

Event name

tmnxSfmIcPortUp

SNMP notification prefix and OID

TIMETRA-CHASSIS-INTERCONNECT-MIB.tmnxSfmIcPortNotifications.2

Default severity

minor

Message format string

SFM interconnect port is operational

Cause

The tmnxSfmIcPortUp notification is generated when the SFM interconnect port is operational again.

Effect

This port can now be used as part of the user plane fabric between chassis.

Recovery

N/A

tmnxSyncIfTimBITS2048khzUnsup

Table 288. tmnxSyncIfTimBITS2048khzUnsup properties

Property name

Value

Application name

CHASSIS

Event ID

2134

Event name

tmnxSyncIfTimBITS2048khzUnsup

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.123

Default severity

major

Message format string

The revision of $tmnxHwIndex$ does not meet the specifications to support the 2048kHz BITS interface type.

Cause

The tmnxSyncIfTimBITS2048khzUnsup notification is generated when the value of tSyncIfTimingAdmBITSIfType is set to 'g703-2048khz (5)' and the CPM does not meet the specifications for the 2048kHz BITS output signal under G.703.

Effect

The BITS input will not be used as the Sync reference and the 2048kHz BITS output signal generated by the CPM is squelched.

Recovery

Replace the CPM with one that is capable of generating the 2048kHz BITS output signal, or set tSyncIfTimingAdmBITSIfType to a value other than 'g703-2048khz (5)'.

tmnxSyncIfTimBITS2048khzUnsupClr

Table 289. tmnxSyncIfTimBITS2048khzUnsupClr properties

Property name

Value

Application name

CHASSIS

Event ID

2135

Event name

tmnxSyncIfTimBITS2048khzUnsupClr

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.124

Default severity

major

Message format string

$tmnxHwIndex$ has been replaced with a CPM that meets the specification for 2048kHz or the BITS interface type is no longer 2048kHz.

Cause

The tmnxSyncIfTimBITS2048khzUnsupClr notification is generated when a tmnxSyncIfTimBITS2048khzUnsup notification is outstanding and the CPM was replaced with one that meets the specifications for the 2048kHz BITS output signal under G.703 or tSyncIfTimingAdmBITSIfType is set to a value other than 'g703-2048khz (5)'.

Effect

The CPM can now support the configuration of tSyncIfTimingAdmBITSIfType.

Recovery

No recovery required.

tmnxTunnelGrpEsaVmActivity

Table 290. tmnxTunnelGrpEsaVmActivity properties

Property name

Value

Application name

CHASSIS

Event ID

2208

Event name

tmnxTunnelGrpEsaVmActivity

SNMP notification prefix and OID

TIMETRA-CHASSIS-MIB.tmnxChassisNotification.219

Default severity

minor

Message format string

esa-$tmnxEsaId$/ $tmnxEsaVmId$ is $tmnxTunnelGrpEsaVmActive$ in tunnel group $tmnxTunnelGrpEsaVmGroupAssoc$

Cause

The tmnxTunnelGrpEsaVmActivity notification is generated when a tunnel-capable ESA virtual machine that is associated with a tunnel group becomes active or inactive within its group.

Effect

N/A

Recovery

N/A