ISIS
tmnxIsisAdjacencyChange
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2045 |
Event name | tmnxIsisAdjacencyChange |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.17 |
Default severity | warning |
Message format string | Adjacency status changed to $isisISAdjState$ for interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$, LSP-id: $vRtrIsisTrapLSPIDString$ |
Cause | The tmnxIsisAdjacencyChange notification is sent when an adjacency changes state, entering or leaving state up. The first 6 bytes of the tmnxIsisNotifTrapLSPID are the SystemID of the adjacent IS. The isisISAdjState is the new state of the adjacency. |
Effect | No effect. |
Recovery | No recovery is necessary. |
tmnxIsisAdjBfdSessionSetupFail
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2062 |
Event name | tmnxIsisAdjBfdSessionSetupFail |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.34 |
Default severity | warning |
Message format string | BFD session setup failed with reason $tmnxIsisBfdSessSetupFailReason$ for interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$, LSP-id: $tmnxIsisNotifTrapLSPIDString$ |
Cause | The tmnxIsisAdjBfdSessionSetupFail notification is sent when BFD session setup fails. The first 6 bytes of the tmnxIsisNotifTrapLSPID are the SystemID of the adjacent IS. |
Effect | The system can not setup the BFD session. |
Recovery | Depending on the tmnxIsisBfdSessSetupFailReason, recovery can be possible. Check the BFD configuration to recover. |
tmnxIsisAdjRestartStatusChange
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2047 |
Event name | tmnxIsisAdjRestartStatusChange |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.19 |
Default severity | warning |
Message format string | Adjacency graceful restart status changed to $tmnxIsisISAdjRestartStatus$ for interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$ |
Cause |
The tmnxIsisAdjRestartStatusChange notification is sent when an adjacency's graceful restart status changes. The tmnxIsisISAdjRestartStatus is the new graceful restart state of the adjacency. |
Effect | No effect. |
Recovery | No recovery is necessary. |
tmnxIsisAreaMismatch
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2040 |
Event name | tmnxIsisAreaMismatch |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.12 |
Default severity | warning |
Message format string | Area mismatch on interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$, fragment: $vRtrIsisPDUFragmentString$, LSP size: $tmnxIsisNotifLSPSize$ |
Cause | The tmnxIsisAreaMismatch notification is sent when we receive a Hello PDU from an IS which does not share any area address. This notification includes the header of the packet, which may help a network manager identify the source of the confusion. This should be an edge-triggered notification. We should not send a second notification about PDUs received from what seem to be the same source. This decision is up to the agent to make, and may be based on the circuit or on some MAC level information. |
Effect | No effect. |
Recovery | No recovery is necessary. |
tmnxIsisAuthFail
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2038 |
Event name | tmnxIsisAuthFail |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.10 |
Default severity | warning |
Message format string | Authentication failure on interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$, fragment: $vRtrIsisPDUFragmentString$ |
Cause |
The tmnxIsisAuthFail notification is sent when we receive a PDU with incorrect authentication information field. This notification includes the header of the packet, which may help a network manager identify the source of the confusion. This should be an edge-triggered notification. We should not send a second notification about PDUs received from what seem to be the same source. |
Effect | No effect. |
Recovery | No recovery is necessary. |
tmnxIsisAutTypeFail
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2037 |
Event name | tmnxIsisAutTypeFail |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.9 |
Default severity | warning |
Message format string | Authentication type failure on interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$, fragment: $vRtrIsisPDUFragmentString$ |
Cause |
The tmnxIsisAutTypeFail notification is sent when we receive a PDU with the wrong authentication type field. This notification includes the header of the packet, which may help a network manager identify the source of the confusion. This should be an edge-triggered notification. We should not send a second notification about PDUs received from what seem to be the same source. |
Effect | No effect. |
Recovery | No recovery is necessary. |
tmnxIsisCircIdExhausted
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2046 |
Event name | tmnxIsisCircIdExhausted |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.18 |
Default severity | warning |
Message format string | Circuit-id space exhausted for level $tmnxIsisNotifSystemLevel$ - interface: $vRtrIfIndex$ |
Cause | The tmnxIsisCircIdExhausted notification is sent when the specific ISIS level cannot be started on a LAN interface as a unique circid could not be assigned due to the exhaustion of the circid space. This could happen only on the broadcast interfaces. |
Effect | In such a case the interface is marked operationally down. |
Recovery | When an operationally up interface is deleted, the circid can be reused by any interface which is waiting to receive a unique circid. |
tmnxIsisCircMtuTooLow
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2064 |
Event name | tmnxIsisCircMtuTooLow |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.36 |
Default severity | warning |
Message format string | MTU size too low for interface: $vRtrIfIndex$ (level $tmnxIsisNotifSystemLevel$): $tmnxIsisNotifCircMtuSize$ smaller than $tmnxIsisNotifCircMinReqMtuSize$ (min required MTU size to transmit LSP or SNP) |
Cause | The tmnxIsisCircMtuTooLow notification is sent when we attempt to a) configure a circuit which cannot propagate an LSP or SNP with max size tmnxIsisLevelLSPBuffSize. b) configure tmnxIsisLevelLSPBuffSize which is bigger than tmnxIsisLevelMaxOperLSPBuffSize. c) configure tmnxIsisSysOrigL1LSPBuffSize or tmnxIsisSysOrigL2LSPBuffSize which is bigger than tmnxIsisLevelMaxOperLSPBuffSize. |
Effect | No effect. |
Recovery | Increase port-mtu or decrease lsp-mtu. |
tmnxIsisCorruptedLSPDetected
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2031 |
Event name | tmnxIsisCorruptedLSPDetected |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.3 |
Default severity | warning |
Message format string | Corrupted LSP detected on interface: $vRtrIfIndex$, level: $tmnxIsisNotifSystemLevel$, with LSP-id: $vRtrIsisTrapLSPIDString$. |
Cause |
The tmnxIsisCorruptedLSPDetected notification is generated when we find that and LSP that was stored in memory has become corrupted. We forward an LSP ID. We may have independent knowledge of the ID, but in some implementations there is a chance that the ID itself will be corrupted. |
Effect | LSP is dropped. |
Recovery | No recovery is necessary. |
tmnxIsisCorruptRemainingLifetime
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2066 |
Event name | tmnxIsisCorruptRemainingLifetime |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.38 |
Default severity | warning |
Message format string | Possible corrupt Remaining Lifetime $tmnxIsisLSPLifetimeRemain$ received on LSP $tmnxIsisLSPIdString$, for level: $tmnxIsisLevel$ |
Cause |
The tmnxIsisCorruptRemainingLifetime notification is sent when an LSP is received with a possible corrupt Remaining Lifetime field. The Remaining Lifetime of a received LSP is considered as possible corrupt based on following algorithm: - The LSP has passed all acceptance tests. - The LSP is newer than the copy in the local LSPDB or no copy present. - The Remaining Lifetime in the received LSP is less than Zero Age Lifetime. - The adjacency to the neighbor from which the LSP is received has been up for a minimum of Zero Age Lifetime. |
Effect | It is possible that an LSP is purged prematurely. |
Recovery | The ISIS system will try to recover by setting the Remaining Lifetime to the tmnxIsisMinRemainingLspLifetime value. |
tmnxIsisDatabaseOverload
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2029 |
Event name | tmnxIsisDatabaseOverload |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.1 |
Default severity | warning |
Message format string | Overload (event $tmnxIsisLevelOverloadStatus$, system level: $tmnxIsisNotifSystemLevel$) - Level1State: $isisSysL1State$, Level2State: $isisSysL2State$ $tmnxIsisNotifyDescription$ |
Cause | The tmnxIsisDatabaseOverload notification is generated when the system enters or leaves the Overload state. |
Effect | Database is overloaded. |
Recovery | No recovery is necessary unless tmnxIsisNotifyDescription indicates it. |
tmnxIsisExportLimitReached
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2050 |
Event name | tmnxIsisExportLimitReached |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.22 |
Default severity | major |
Message format string | ISIS level $tmnxIsisNotifSystemLevel$ has reached the export-limit $tmnxIsisExportLimit$, additional routes will not be exported into this ISIS level |
Cause | The tmnxIsisExportLimitReached notification is sent when the total number of exported routes for the level is equal to the configured limit for exported routes, tmnxIsisExportLimit. |
Effect | Additional routes would not be exported into this ISIS level from the route table. |
Recovery | Change ISIS export policy. |
tmnxIsisExportLimitWarning
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2051 |
Event name | tmnxIsisExportLimitWarning |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.23 |
Default severity | warning |
Message format string | ISIS level $tmnxIsisNotifSystemLevel$ has reached $tmnxIsisExportLimitLogPercent$ percent of the export limit $tmnxIsisExportLimit$ |
Cause | The tmnxIsisExportLimitWarning notification is sent when the total number of exported routes or the level is equal to the configured percent, tmnxIsisExportLimitLogPercent of the export limit, tmnxIsisExportLimit. Additional routes will continue to be exported into this ISIS level from the route table till the export limit is reached. |
Effect | No effect. |
Recovery | No recovery is necessary. |
tmnxIsisFailureDisabled
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2056 |
Event name | tmnxIsisFailureDisabled |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.28 |
Default severity | minor |
Message format string | ISIS disabled. Reason : $tmnxIsisFailureReasonCode$ |
Cause |
A tmnxIsisFailureDisabled notification is generated when ISIS is operationally brought down. Reason for the failure is indicated by tmnxIsisFailureReasonCode. |
Effect | ISIS is now operationally down. |
Recovery | ISIS will auto restart. |
tmnxIsisFaOperParticipationDown
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2068 |
Event name | tmnxIsisFaOperParticipationDown |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.40 |
Default severity | warning |
Message format string | The oper-participation of $tmnxIsisFlexAlgoId$ in level $tmnxIsisNotifSystemLevel$ is operationally down due to $tmnxIsisNotifyDescription$. |
Cause |
The tmnxIsisFaOperParticipationDown notification is sent when the Flexible Algorithm Participation is operationally down. This notification occurs each time when: a) there are no Flexible Algorithm Definitions(FADs) present for the Flexible Algorithm. b) the FAD chosen for Flex-Algo calculation has unsupported parameters like unsupported: 1. Metric-Type 2. Calculation-Type 3. Constraint 4. Fad-Flags 5. Sub-Tlv |
Effect | The node will cease to participate in that Flexible Algorithm, and won't advertise its participation in SR-algo sub-TLV. |
Recovery | The operator may make sure if at least one FAD is present for that Flexible Algorithm, and in case of unsupported FAD, correct the FAD parameters to send supported values from remote side. |
tmnxIsisIDLenMismatch
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2033 |
Event name | tmnxIsisIDLenMismatch |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.5 |
Default severity | warning |
Message format string | ISIS-id length mismatch - field length: $tmnxIsisNotifFieldLen$, interface: $vRtrIfIndex$, on fragment: $vRtrIsisPDUFragmentString$ |
Cause |
The tmnxIsisIDLenMismatch notification is sent when we receive a PDU with a different value of the System ID Length. This notification includes the index to identify the circuit where we saw the PDU and the header of the PDU which may help a network manager identify the source of the confusion. This should be an edge-triggered notification. We should not send a second notification about PDUs received from what seem to be the same source. This decision is up to the agent to make, and may be based on the circuit or on some MAC level information. |
Effect | No effect. |
Recovery | No recovery is necessary. |
tmnxIsisLdpSyncExit
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2049 |
Event name | tmnxIsisLdpSyncExit |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.21 |
Default severity | warning |
Message format string | IGP-LDP synchronization has stopped for interface $vRtrIfIndex$ because Exit State $tmnxIsisIfLdpSyncTimerState$ |
Cause | The tmnxIsisLdpSyncExit notification is sent when IGP-LDP synchronization has stopped. The cause of this event is indicated by tmnxIsisIfLdpSyncTimerState, one of them being expiry of vRtrIfLdpSyncTimer. |
Effect | The IGP link metric is restored to normal levels. |
Recovery | No recovery is necessary. |
tmnxIsisLdpSyncTimerStarted
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2048 |
Event name | tmnxIsisLdpSyncTimerStarted |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.20 |
Default severity | warning |
Message format string | IGP-LDP synchronization timer has started for interface $vRtrIfIndex$. |
Cause |
The tmnxIsisLdpSyncTimerStarted notification is sent when the vRtrIfLdpSyncTimer is started. The timer is started from the time the LDP session to the neighbor is up over the interface. |
Effect | This allows for the label FEC bindings to be exchanged. |
Recovery | No recovery is necessary. |
tmnxIsisLSPPurge
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2060 |
Event name | tmnxIsisLSPPurge |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.32 |
Default severity | warning |
Message format string | Possible messages:
|
Cause | The tmnxIsisLSPPurge notification is sent when a LSP is purged. This notification includes the system ID of the originator, or the upstream source of the purge, which may help a network manager to locate the origin of the purge and thus the cause of the purge. |
Effect | No effect. |
Recovery | No recovery is necessary. |
tmnxIsisLSPTooLargeToPropagate
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2042 |
Event name | tmnxIsisLSPTooLargeToPropagate |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.14 |
Default severity | warning |
Message format string | LSP too large to propagate - LSP size: $tmnxIsisNotifLSPSize$, on interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$, LSP-id: $vRtrIsisTrapLSPIDString$ |
Cause | The tmnxIsisLSPTooLargeToPropagate notification is sent when we attempt to propagate an LSP which is larger than the dataLinkBlockSize for a circuit. This should be an edge-triggered notification. We should not send a second notification about PDUs received from the same source. |
Effect | No effect. |
Recovery | No recovery is necessary. |
tmnxIsisManualAddressDrops
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2030 |
Event name | tmnxIsisManualAddressDrops |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.2 |
Default severity | warning |
Message format string | Configured manual area address $isisManAreaAddrString$ being ignored when computing routes |
Cause | This notification is generated when one of the manual area addresses assigned to this system is ignored when computing routes. The object isisManAreaAddrExistState describes the area that has been dropped. This notification is edge triggered, and should not be regenerated until an address that was used in the previous computation has been dropped. |
Effect | Assigned manual area address is ignored for computing routes. |
Recovery | No recovery is necessary. |
tmnxIsisMaxAreaAddrsMismatch
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2034 |
Event name | tmnxIsisMaxAreaAddrsMismatch |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.6 |
Default severity | warning |
Message format string | Max area addresses mismatch - max area addresses: $tmnxIsisNotifMaxAreaAddress$, interface: $vRtrIfIndex$, on fragment: $vRtrIsisPDUFragmentString$ |
Cause |
The tmnxIsisMaxAreaAddrsMismatch notification is sent when we receive a PDU with a different value of the Maximum Area Addresses. This notification includes the header of the packet, which may help a network manager identify the source of the confusion. This should be an edge-triggered notification. We should not send a second notification about PDUs received from what seem to be the same source. |
Effect | No effect. |
Recovery | No recovery is necessary. |
tmnxIsisMaxSeqExceedAttempt
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2032 |
Event name | tmnxIsisMaxSeqExceedAttempt |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.4 |
Default severity | warning |
Message format string | Protocol disabled due to attempt to exceed the maximum sequence on level: $tmnxIsisNotifSystemLevel$, with LSP-id: $vRtrIsisTrapLSPIDString$. Shutdown for a while and start over. |
Cause | The tmnxIsisMaxSeqExceedAttempt notification is generated when the sequence number on an LSP wraps the 32 bit sequence counter, we purge and wait to re-announce this information. Since these should not be generated rapidly, we generate an event each time this happens. A possible cause could be that the same system-id is configured on multiple nodes; when 2 nodes have the same system-id they both keep incrementing its LSP sequence number causing the sequence counter to rollover. While the first 6 bytes of the LSPID are ours, the other two contain useful information. |
Effect | No effect. |
Recovery | No recovery is necessary. |
tmnxIsisOrigLSPBufSizeMismatch
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2043 |
Event name | tmnxIsisOrigLSPBufSizeMismatch |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.15 |
Default severity | warning |
Message format string | Originating LSP buffer size mismatch - LSP size: $tmnxIsisNotifOriginatingBuffSize$, on interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$, LSP-id: $vRtrIsisTrapLSPIDString$ |
Cause | The tmnxIsisOrigLSPBufSizeMismatch notification is sent when a Level 1 LSP or Level 2 LSP is received which is larger than the local value for isisSysOrigL1LSPBuffSize or isisSysOrigL2LSPBuffSize respectively, or when a Level 1 LSP or Level2 LSP is received containing the originatingLSPBufferSize option and the value in the PDU option field does not match the local value for isisSysOrigL1LSPBuffSize or isisSysOrigL2LSPBuffSize respectively. We pass up the size from the option field or the size of the LSP that exceeds our configuration. This should be an edge-triggered notification. We should not send a second notification about PDUs received from the same source. |
Effect | No effect. |
Recovery | No recovery is necessary. |
tmnxIsisOwnLSPPurge
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2035 |
Event name | tmnxIsisOwnLSPPurge |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.7 |
Default severity | warning |
Message format string | Own LSP Purge - interface: $vRtrIfIndex$, on level: $tmnxIsisNotifSystemLevel$, LSP: $vRtrIsisTrapLSPIDString$ |
Cause |
The tmnxIsisOwnLSPPurge notification is sent when we receive a PDU with our SystemID and zero age. This notification includes the circuit Index if available, which may help a network manager identify the source of the confusion. |
Effect | No effect. |
Recovery | No recovery is necessary. |
tmnxIsisPfxLimitOverloadWarning
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2061 |
Event name | tmnxIsisPfxLimitOverloadWarning |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.33 |
Default severity | warning |
Message format string | Overload warning $tmnxIsisNotifAdditionalInfo$ |
Cause |
The tmnxIsisPfxLimitOverloadWarning notification is sent when the number of prefixes in the system reaches the tmnxIsisPrefixLimitThreshold or the tmnxIsisPrefixLimit. |
Effect | When tmnxIsisPrefixLimit is not yet reached, but the tmnxIsisPrefixLimitThreshold is reached there is no direct effect; but when the number of prefixes grows the system might go into overload. When the tmnxIsisPrefixLimit is reached and the object tmnxIsisPrefixLimitLogOnly is false, IS-IS will be into overload. There is no direct effect when the object tmnxIsisPrefixLimitLogOnly is true. |
Recovery | Increase the IS-IS prefix limit. |
tmnxIsisProtoSuppMismatch
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2044 |
Event name | tmnxIsisProtoSuppMismatch |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.16 |
Default severity | warning |
Message format string | Supported protocol mismatch - supported protocol: $tmnxIsisNotifProtocolsSupported$, on interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$, LSP-id: $vRtrIsisTrapLSPIDString$ |
Cause | The tmnxIsisProtoSuppMismatch notification is sent when a non-pseudonode segment 0 LSP is received that has no matching protocols supported. This may be because the system does not generate the field, or because there are no common elements. The list of protocols supported should be included in the notification: it may be empty if the TLV is not supported, or if the TLV is empty. This should be an edge-triggered notification. We should not send a second notification about PDUs received from the same source. |
Effect | No effect. |
Recovery | No recovery is necessary. |
tmnxIsisRejectedAdjacency
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2041 |
Event name | tmnxIsisRejectedAdjacency |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.13 |
Default severity | warning |
Message format string | Rejected adjacency on interface: $vRtrIfIndex$, for level:$tmnxIsisNotifSystemLevel$ |
Cause | The tmnxIsisRejectedAdjacency notification is sent when we receive a Hello PDU from an IS, but do not establish an adjacency due to a lack of resources. This should be an edge-triggered notification. We should not send a second notification about PDUs received from the same source. |
Effect | No effect. |
Recovery | No recovery is necessary. |
tmnxIsisRejectedAdjacencySet
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2065 |
Event name | tmnxIsisRejectedAdjacencySet |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.37 |
Default severity | warning |
Message format string | Failed adj-set on interface: $tmnxIsisNotifyIfIndex$, for level:$tmnxIsisNotifSystemLevel$, description: $tmnxIsisNotifyDescription$ |
Cause |
The tmnxIsisRejectedAdjacencySet notification is sent when an adjacency can not be assigned to an adjacency-set because it does not terminate on the same neighbor node as the other adjacencies. This notification each time the adjacency-set is programmed. |
Effect | Adjacency-set nhops will not include this adjacency. |
Recovery | Remove the interface from the adjacency-set or change the adjacency-set type to non parallel. |
tmnxIsisRejectedAdjacencySid
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2059 |
Event name | tmnxIsisRejectedAdjacencySid |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.31 |
Default severity | warning |
Message format string | Failed SID adjacency on interface: $vRtrIfIndex$, for level:$tmnxIsisNotifSystemLevel$, description: $tmnxIsisNotifyDescription$ |
Cause |
The tmnxIsisRejectedAdjacencySid notification is sent when we do not establish an adjacency SID or adjacency PGID due to a lack of resources. This should be an edge-triggered notification. We should not send a second notification about adjacency SID allocation failure for the same adjacency. We should not send a second notification about adjacency PGID allocation failure for the same adjacency. |
Effect | No effect. |
Recovery | Whenever an ADJ-SID is released, the released ADJ-SID can be reused by any other adjacency which is waiting to receive an ADJ-SID. Whenever a PGID is released, the released PGID can be reused by any other adjacency which is waiting to receive a PGID. |
tmnxIsisRejectedEndXSid
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2069 |
Event name | tmnxIsisRejectedEndXSid |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.41 |
Default severity | warning |
Message format string | Failed end-x SID on interface: $vRtrIfIndex$, for level:$tmnxIsisNotifSystemLevel$, description: $tmnxIsisNotifyDescription$ |
Cause |
The tmnxIsisRejectedEndXSid notification is sent when we do not establish a SRv6 End-X SID due to a lack of resources. This should be an edge-triggered notification. We should not send a second notification about end-x SID allocation failure for the same adjacency. |
Effect | No effect. |
Recovery | Whenever an end-x SID is released, the released end-x SID can be reused by any other adjacency which is waiting to receive an end-x SID. |
tmnxIsisRejectedPgId
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2070 |
Event name | tmnxIsisRejectedPgId |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.42 |
Default severity | warning |
Message format string | Failed PGID on interface: $vRtrIfIndex$, for level:$tmnxIsisNotifSystemLevel$, description: $tmnxIsisNotifyDescription$ |
Cause |
The tmnxIsisRejectedPgId notification is sent when we do not establish a SRv6 adjacency PGID due to a lack of resources. This should be an edge-triggered notification. We should not send a second notification about adjacency PGID allocation failure for the same adjacency. |
Effect | No effect. |
Recovery | Whenever a PGID is released, the released PGID can be reused by any other adjacency which is waiting to receive a PGID. |
tmnxIsisRoutesExpLmtDropped
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2052 |
Event name | tmnxIsisRoutesExpLmtDropped |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.24 |
Default severity | warning |
Message format string | The number of redistributed routes into ISIS level $tmnxIsisNotifSystemLevel$ has dropped below the export limit $tmnxIsisExportLimit$ |
Cause | The tmnxIsisRoutesExpLmtDropped notification is sent when the total number of exported routes from the route table to this ISIS level drops below the configured export limit, tmnxIsisExportLimit. |
Effect | No effect. |
Recovery | No recovery is necessary. |
tmnxIsisSequenceNumberSkip
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2036 |
Event name | tmnxIsisSequenceNumberSkip |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.8 |
Default severity | warning |
Message format string | Sequence number skipped for LSP: $vRtrIsisTrapLSPIDString$, on interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$ |
Cause |
The tmnxIsisSequenceNumberSkip notification is sent when we need to increase the sequence number by more than one. When we receive an LSP without System ID and different contents, we may need to reissue the LSP with a higher sequence number. If two Intermediate Systems are configured with the same System ID, this notification will fire. |
Effect | No effect. |
Recovery | No recovery is necessary. |
tmnxIsisSidError
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2057 |
Event name | tmnxIsisSidError |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.29 |
Default severity | minor |
Message format string | $tmnxIsisNotifyDescription$ SID: $tmnxIsisPrefixSidValue$, level:$tmnxIsisPrefixSidLevel$, mtid: $tmnxIsisRouteMtId$, type:$tmnxIsisPrefixSidType$, flags: $tmnxIsisPrefixSidFlags$, algo:$tmnxIsisPrefixSidAlgorithm$ |
Cause | This notification is generated when ISIS receives an IOM or CPM failure (system exhausted ILM, NHLFE, duplicate SID) while resolving and programming a received prefix SID. |
Effect | The Segment Routing tunnel corresponding to this SID will not be programmed. |
Recovery | In case of system exhaustion, the IGP instance goes into overload. The operator must manually clear the IGP overload condition after freeing resources. IGP will attempt to program at the next SPF all tunnels which previously failed the programming operation |
tmnxIsisSidNotInLabelRange
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2058 |
Event name | tmnxIsisSidNotInLabelRange |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.30 |
Default severity | minor |
Message format string | SID not in range of router: $tmnxIsisNotifPfxSidSysIDString$, SID:$tmnxIsisPrefixSidValue$, startLabel: $tmnxIsisNotifPfxSidRangeStartLbl$, maxIdx:$tmnxIsisNotifPfxSidRangeMaxIdx$ level: $tmnxIsisPrefixSidLevel$, mtid:$tmnxIsisRouteMtId$, type: $tmnxIsisPrefixSidType$, flags:$tmnxIsisPrefixSidFlags$, algo: $tmnxIsisPrefixSidAlgorithm$ |
Cause |
This notification is generated when ISIS receives a SID which is not within the label range of the nhop router. |
Effect | The Segment Routing tunnel corresponding to this SID will not be programmed. |
Recovery | Increase the label range or change the SID index to be within the current label range. |
tmnxIsisSidStatsIndexAlloc
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2067 |
Event name | tmnxIsisSidStatsIndexAlloc |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.39 |
Default severity | warning |
Message format string | Possible messages:
|
Cause | The tmnxIsisSidStatsIndexAlloc notification is sent when the system is not able to allocate a statistic index to at least one SID. This indication is sent once, i.e. if the system retries to allocate a stat index but fails no new notification is sent. Conversely, in case the system resolves the situation and allocates stat indices to all needed SIDs a notification is sent to indicate that stat allocation is in nominal state. |
Effect | No effect. |
Recovery | No recovery is necessary. |
tmnxIsisSrgbBadLabelRange
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2063 |
Event name | tmnxIsisSrgbBadLabelRange |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.35 |
Default severity | warning |
Message format string | Bad SRGB label range for advertising router: $tmnxIsisNotifSrgbAdvRtrSysIDString$, startLabel:$tmnxIsisNotifSrgbRangeStartLbl$, maxIdx: $tmnxIsisNotifSrgbRangeMaxIdx$, level:$tmnxIsisNotifSrgbLevel$, mtid: $tmnxIsisNotifSrgbMtId$ $tmnxIsisNotifAdditionalInfo$ |
Cause | The tmnxIsisSrgbBadLabelRange notification is sent when ISIS receives a bad SRGB label range from a router (for example, overlapping with another label range). |
Effect | The configured Segment Routing tunnels will be wrong. |
Recovery | Change the label range to recover. |
tmnxIsisSrv6LocError
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2071 |
Event name | tmnxIsisSrv6LocError |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.43 |
Default severity | warning |
Message format string | $tmnxIsisNotifyDescription$, level: $tmnxIsisNotifSystemLevel$, mtid:$tmnxIsisRouteMtId$, algo: $tmnxIsisSrv6SidAlgorithm$ |
Cause |
This notification is generated when ISIS receives an IOM or CPM failure (system exhausted ILM, NHLFE, duplicate SID) while resolving and programming a received SRv6 locator. |
Effect | The Segment Routing tunnel corresponding to this locator will not be programmed. |
Recovery | In case of system exhaustion, the IGP instance goes into overload. The operator must manually clear the IGP overload condition after freeing resources. IGP will attempt to program at the next SPF all SRv6 tunnels which previously failed the programming operation |
tmnxIsisVersionSkew
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2039 |
Event name | tmnxIsisVersionSkew |
SNMP notification prefix and OID | TIMETRA-ISIS-NG-MIB.tmnxIsisNotifications.11 |
Default severity | warning |
Message format string | Protocol version skew - $tmnxIsisNotifProtocolVersion$ on interface: $vRtrIfIndex$, for level: $tmnxIsisNotifSystemLevel$, fragment: $vRtrIsisPDUFragmentString$ |
Cause | The tmnxIsisVersionSkew notification is sent when we receive a Hello PDU from an IS running a different version of the protocol. This notification includes the header of the packet, which may help a network manager identify the source of the confusion. This should be an edge-triggered notification. We should not send a second notification about PDUs received from what seem to be the same source. This decision is up to the agent to make, and may be based on the circuit or on some MAC level information. |
Effect | No effect. |
Recovery | No recovery is necessary. |
vRtrIsisSpbNbrMultAdjExists
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2025 |
Event name | vRtrIsisSpbNbrMultAdjExists |
SNMP notification prefix and OID | TIMETRA-ISIS-MIB.vRtrIsisNotifications.25 |
Default severity | warning |
Message format string | SPB multiple adjacency exists for neighbor $vRtrIsisNbrSysIdString$ on interface $vRtrIfIndex$ at system level $vRtrIsisSystemLevel$ |
Cause |
A vRtrIsisSpbNbrMultAdjExists notification is sent when IS-IS SPB instance detects a neighbor to which it already has a direct adjacency on another interface. |
Effect | During SPF IS-IS SPB instance will have incorrect neighbor information and hence path computations will be incorrect. |
Recovery | Check number of links to neighbor to make sure there is only one link. |
vRtrIsisSpbNbrMultAdjExistsClear
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2026 |
Event name | vRtrIsisSpbNbrMultAdjExistsClear |
SNMP notification prefix and OID | TIMETRA-ISIS-MIB.vRtrIsisNotifications.26 |
Default severity | warning |
Message format string | SPB multiple adjacency cleared for neighbor $vRtrIsisNbrSysIdString$ on interface $vRtrIfIndex$ at system level $vRtrIsisSystemLevel$ |
Cause |
A vRtrIsisSpbNbrMultAdjExistsClear notification is sent when an IS-IS SPB instance clears the condition raised by vRtrIsisSpbNbrMultAdjExists notification. |
Effect | During SPF IS-IS SPB instance will have correct neighbor information and hence path computations will be correct. |
Recovery | None required. |
vRtrSpbEctFidCfgChg
Property name | Value |
---|---|
Application name | ISIS |
Event ID | 2027 |
Event name | vRtrSpbEctFidCfgChg |
SNMP notification prefix and OID | TIMETRA-ISIS-MIB.vRtrIsisNotifications.27 |
Default severity | warning |
Message format string | SPB ect-algorithm changed to $vRtrSpbEctFidAlgorithm$ for FID range $vRtrSpbEctFidStart$- $vRtrSpbEctFidEnd$ under $vRtrIsisLevel$ |
Cause | A vRtrSpbEctFidCfgChg notification is sent when a configuration change is made to vRtrSpbEctFidTable affecting forwarding database identifiers in the range from vRtrSpbEctFidStart to vRtrSpbEctFidEnd. |
Effect | There are changes in the vRtrSpbEctFidTable which may be out-of-sync with management application. |
Recovery | Management application may need to synchronize with changes in the vRtrSpbEctFidTable. |